Výsledky hledání

sektor: energetika× v celém archivu zrušit filtry

78 karet z 79 položek · strana 1 z 2 CZ · EN/orig

8

Pyramid Solutions NetStaX EtherNet/IP Stack

View CSAF Summary Successful exploitation of this vulnerability could result in memory corruption, a device crash, or a potential remote attack vector without the originating device receiving a CIP error indicating that the request could not be processed. The following versions of Pyramid Solutions NetStaX EtherNet/IP Stack are affected: EtherNet/IP Adapter DLL Kit (EIPA) EtherNet/IP Adapter DLL Kit with CIP Security (EIPA-SECURE) EtherNet/IP Adapter Development Kit (EADK) EtherNet/IP Adapter…

EPSS 0.00 CVSS 9.8 CVE-2026-78012 Pyramid Solutions výroba a průmysl energetika vodárenství obrana US

tg: zneužíváno tg: zranitelnost tp: průmyslové systémy

CISA Advisories ·

IXON VPN Client

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to perform remote code execution on the computer running the client with elevated privileges. The following versions of IXON VPN Client are affected: VPN Client <1.4.7 (CVE-2026-75925) CVSS Vendor Equipment Vulnerabilities v3 9.6 IXON IXON VPN Client Improper Neutralization of CRLF Sequences ('CRLF Injection') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy,…

CVSS 9.6 CVE-2026-75925 IXON energetika vodárenství výroba a průmysl US

tg: zneužíváno tg: zranitelnost tp: průmyslové systémy

CISA Advisories ·

Rockwell Automation ControlFLASH

View CSAF Summary Successful exploitation of this vulnerability could give an attacker the ability to run any commands or code of the attacker's choice on a target machine at the logged-in user's permission level. The following versions of Rockwell Automation ControlFLASH are affected: ControlFLASH <=V15.07 (CVE-2026-12663) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation ControlFLASH Missing Authentication for Critical Function Background Critical…

EPSS 0.00 CVSS 7.3 CVE-2026-12663 Rockwell Automation výroba a průmysl energetika vodárenství US

tg: zranitelnost tp: průmyslové systémy

CISA Advisories ·

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

View CSAF Summary Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra…

EPSS 0.00 CVSS 8.3 CVE-2026-4827 Schneider Electric energetika vodárenství US

tg: zneužíváno tg: zranitelnost tp: průmyslové systémy

CISA Advisories ·

Tycon Systems TPDIN-Monitor-WEB3

View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to perform a man-in-the-middle (MitM) attack, cause a factory reset, wipe credentials, or retrieve sensitive information. The following versions of Tycon Systems TPDIN-Monitor-WEB3 are affected: TPDIN-Monitor-WEB3 <=2.2.9 (CVE-2026-77847, CVE-2026-82712, CVE-2026-82684) CVSS Vendor Equipment Vulnerabilities v3 8.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB3 Use of Hard-coded Credentials, Cross-Site…

CVSS 8.8 CVE-2026-77847 CVE-2026-82684 CVE-2026-82712 Tycon Systems výroba a průmysl energetika US

tg: zranitelnost

CISA Advisories ·

OPCFoundation OPC UA LocalDiscoveryServer (LDS)

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to take control of a high-privilege terminal during installation and run arbitrary commands. The following versions of OPCFoundation OPC UA LocalDiscoveryServer (LDS) are affected: UA-LDS-Installers <1.04.420 (CVE-2026-77477) CVSS Vendor Equipment Vulnerabilities v3 4.6 OPCFoundation OPCFoundation OPC UA LocalDiscoveryServer (LDS) Execution with Unnecessary Privileges Background Critical Infrastructure…

CVSS 4.6 CVE-2026-77477 OPCFoundation energetika vodárenství výroba a průmysl obrana US

tg: zranitelnost tp: průmyslové systémy

CISA Advisories ·

Inductive Automation Ignition

View CSAF Summary Successful exploitation of this vulnerability could allow any authenticated user to create projects. The following versions of Inductive Automation Ignition are affected: Ignition <=8.1.53 (CVE-2026-77393) CVSS Vendor Equipment Vulnerabilities v3 8.8 Inductive Automation Inductive Automation Ignition Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company…

CVSS 8.8 CVE-2026-77393 Inductive Automation výroba a průmysl energetika US

tg: zranitelnost tp: průmyslové systémy

CISA Advisories ·

Cisco Nexus 9000 Series Switches Silicon One Remote Code Execution Vulnerability

Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.8, CVEs: CVE-2026-20212, Summary: A vulnerability in the Silicon One integration for Cisco Nexus 9000 Series Switches could allow an unauthenticated, remote attacker to execute code with root privileges. This vulnerability exists because TCP ports 43210 and 43211 are accessible in the default Layer 3 (L3) virtual routing and forwarding (VRF). A successful exploit could allow the attacker to connect to…

CVSS 9.8 CVE-2026-20212 Cisco telekomunikace energetika finance veřejná správa FI US 2 zdrojů

tg: zneužíváno tg: zranitelnost tp: průmyslové systémy

NCSC-FI · Cisco PSIRT

1

[Control systems] Schneider Electric security advisory (AV26-871)

Serial Number: AV26-871Date: September 2, 2026 As of September 1, 2026, Schneider Electric is affected by vulnerabilities in the following products: NetBotz 5 - 750/755 Versions prior to or equal to 5.5.2 PowerChute Serial Shutdown Versions prior to or equal to 1.5 The Cyber Centre encourages users and administrators to review the provided web links, perform the suggested mitigations and apply the necessary updates. Multiple Vulnerabilities on NetBotz 5 - 750/755 Products Improper Restriction…

Schneider Electric výroba a průmysl energetika CA

tg: zranitelnost tp: průmyslové systémy

Cyber Centre Kanada ·

2

Rockwell Automation Redundancy Module Configuration Tool

View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to escalate and execute processes with administrator privileges. The following versions of Rockwell Automation Redundancy Module Configuration Tool are affected: Redundancy Module Configuration Tool 10.00.00 (CVE-2026-9633) Redundancy Module Configuration Tool >=9.00.00|<=10.00.00 (CVE-2026-9634) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation Redundancy Module…

CVSS 7.3 CVE-2026-9633 CVE-2026-9634 Rockwell Automation výroba a průmysl energetika vodárenství doprava US

tg: zranitelnost tp: průmyslové systémy

CISA Advisories ·

Rockwell Automation Historian ME

View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed; an out-of-bounds write condition may allow remote code execution. The following versions of Rockwell Automation Historian ME are affected: Series B 5.202 (CVE-2025-12768, CVE-2026-12661) Series C 7.101 (CVE-2025-12768, CVE-2026-12661) CVSS Vendor Equipment Vulnerabilities v3 8 Rockwell Automation Rockwell Automation Historian ME Out-of-bounds Write, Stack-based Buffer Overflow Background…

CVSS 8.0 CVE-2025-12768 CVE-2026-12661 Rockwell Automation výroba a průmysl energetika vodárenství zdravotnictví US

tg: zranitelnost tp: průmyslové systémy

CISA Advisories ·

1

[Control Systems] Siemens security advisory (AV26-864)

Serial Number: AV26-864Date: August 31, 2026 As of August 27, 2026, Siemens is affected by a vulnerability in the following products: Element maps-ng V47 Prior to V47.12.3 Element maps-ng V48 Prior to V48.11.3 Element maps-ng V49 Prior to V49.16.1 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. SSA-682041 CERT Services | Siemens

Siemens energetika výroba a průmysl CA

tg: zranitelnost tp: průmyslové systémy

Cyber Centre Kanada ·

1

[Control Systems] National Instruments security advisory (AV26-856)

Serial Number: AV26-856Date: August 28, 2026 As of August 25, 2026, National Instruments is affected by vulnerabilities in the following product: LabVIEW Prior to 23.0.0 Prior to 23.3.10 Prior to 24.3.7 Prior to 25.3.5 Prior to 26.3.1 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. Memory Corruption Vulnerabilities in NI LabVIEW - NI Integer Conversion Vulnerability Resulting in an Out of Bounds Read…

National Instruments výroba a průmysl energetika vodárenství telekomunikace CA

tg: zranitelnost tp: průmyslové systémy

Cyber Centre Kanada ·

4

Applied Systems Engineering ASE2000 V2 Communications Test Set

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to read or write arbitrary local files, cause the application to issue outbound network requests, or intercept the connection to impersonate the trusted peer, complete the TLS handshake, and read or modify the protected communications. The following versions of Applied Systems Engineering ASE2000 V2 Communications Test Set are affected: ASE2000 >=2.25|<=2.37 (CVE-2018-1285, CVE-2026-18717) CVSS Vendor…

EPSS 0.17 CVSS 9.8 CVE-2018-1285 CVE-2026-18717 Applied Systems Engineering energetika vodárenství výroba a průmysl US

CISA Advisories ·

Threat landscape for industrial automation systems. Q2 2026

All threats In Q2 2026, the percentage of ICS computers on which malicious objects were blocked continued to decrease, falling to 19.15%, its lowest level since 2022. Percentage of ICS computers on which malicious objects were blocked, Q3 2023–Q2 2026 Regionally, the percentages ranged from 8.1% in Northern Europe to 27.9% in Africa. Regions ranked by percentage of attacked ICS computers The figures increased in five regions over the quarter, most notably in East Asia (by 2.0 pp) and Africa (by…

Kaspersky výroba a průmysl energetika RU

Securelist (Kaspersky) ·

Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software

Classification: Severe, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.3, CVEs: CVE-2026-15203, Summary: Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanism

EPSS 0.00 CVSS 9.3 CVE-2026-15203 Danfoss výroba a průmysl energetika FI

NCSC-FI ·

1

PLC na internete: aktuálne riziko aj pre kritickú infraštruktúru

Národné centrum kybernetickej bezpečnosti (NCKB) NBÚ upozorňuje na nebezpečenstvo prevádzkovania programovateľných logických radičov (ďalej ako „PLC“) voľne dostupných z verejného internetu. PLC nie je zariadenie, ktoré má byť priamo dostupné z verejného internetu. Programovateľné logické radiče hrajú kľúčovú úlohu takmer vo všetkých odvetviach priemyslu. Ich vystavenie do verejného internetu môže viesť k ohrozeniu útočníkmi s... The post PLC na internete: aktuálne riziko aj pre kritickú…

energetika vodárenství výroba a průmysl telekomunikace SK

SK-CERT (NBÚ SR) ·

3

Siemens SIMATIC IoT2050 Advanced

View CSAF Summary SIMATIC IoT2050 Advanced devices running Industrial OS with Node-RED installed contain a missing authentication vulnerability in the Node-RED HTTP interface that could allow an unauthenticated remote attacker to create malicious flows and execute arbitrary code on the underlying server with maximum privileges. Siemens has released a new version for SIMATIC IoT2050 Advanced and strongly recommends to update to the latest version. The following versions of Siemens SIMATIC…

EPSS 0.01 CVSS 10.0 CVE-2026-58115 Siemens energetika výroba a průmysl doprava US

CISA Advisories ·

Ebyte NE2-D11

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized administrative access, disclose sensitive information, modify device configuration, hijack authenticated sessions, and disrupt device operation. The following versions of Ebyte NE2-D11 are affected: NE2-D11 Firmware FW-9167-0-11 CVSS Vendor Equipment Vulnerabilities v3 9.8 Ebyte Ebyte NE2-D11 Missing Authentication for Critical Function, Cleartext Transmission of Sensitive Information…

EPSS 0.01 CVSS 9.8 CVE-2026-71187 CVE-2026-73125 CVE-2026-73809 CVE-2026-73839 CVE-2026-75814 CVE-2026-76179 CVE-2026-76940 Ebyte výroba a průmysl energetika US

CISA Advisories ·

1

24th August – Threat Intelligence Report

For the latest discoveries in cyber research for the week of 24th August, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES Latvia’s Road Traffic Safety Directorate (CSDD) has confirmed a breach affecting payment records of more than 1.2 million people – roughly two-thirds of the country’s population – as well as 200,000 organizations. The stolen data included identification numbers, license plates, payment amounts, dates and addresses. Attackers reportedly exploited a…

KEV ✓ EPSS 0.41 CVSS 10.0 CVE-2026-12569 CVE-2026-19478 CVE-2026-19489 CVE-2026-19490 Snowflake Siemens GitLab Cisco zdravotnictví výroba a průmysl energetika vodárenství IL

Check Point Research ·

1

CISA Releases One Industrial Control Systems Advisory

Classification: Important, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 5.3, CVEs: CVE-2026-27875, Summary: CISA released one Industrial Control Systems (ICS) Advisory. This advisory provides timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-26-232-01 Johnson Controls Simplex Incident Manager

EPSS 0.00 CVSS 5.8 CVE-2026-27875 Johnson Controls výroba a průmysl energetika doprava veřejná správa FI US 2 zdrojů

NCSC-FI · CISA Advisories

2

Frequently asked questions about the active threat to Siemens S7 Series PLCs

A joint cybersecurity advisory released by multiple U.S. government agencies warns that threat actors are using AI-generated exploitation scripts to target exposed Siemens S7 Series PLCs across critical infrastructure sectors.Key TakeawaysUnattributed threat actors are exploiting known weaknesses and unnecessary internet exposure to conduct reconnaissance and possible pre-positioning for future disruptive attacks against Siemens S7 Series PLCs.The attackers are leveraging AI to build and refine…

Siemens veřejná správa energetika vodárenství výroba a průmysl US

Tenable Research ·

4

Defending Against an Active Threat to Siemens S7 Series PLCs

Executive summary Note: This advisory relates to an active threat to Siemens S7 Series programmable logic controllers (PLCs). However, ongoing PLC targeting activity is broader than Siemens PLCs. All PLC owners and operators should apply relevant mitigations to reduce the risk to their devices and systems. The Siemens-specific content in this advisory should be understood and applied as one subset of the wider threat landscape. Top Mitigations Inventory all Siemens S7 Series programmable logic…

Siemens výroba a průmysl energetika vodárenství obrana US

CISA Advisories ·

2

More than 200 victims of Medusa ransomware identified over the last year, CISA says

The Cybersecurity and Infrastructure Security Agency (CISA) and FBI updated an advisory on the group initially released in March 2025 — writing that as of April 2026, Medusa actors have hit more than 500 victims. CISA previously said 300 victims, many of which are in critical infrastructure sectors, were attacked as of 2025.

veřejná správa energetika vodárenství telekomunikace US

The Record ·

Siemens Simcenter Nastran

View CSAF Summary Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released new versions for the affected products and recommends to update to the latest versions. The…

EPSS 0.00 CVSS 7.8 CVE-2026-59086 Siemens výroba a průmysl obrana energetika zdravotnictví US

CISA Advisories ·

1

17th August – Threat Intelligence Report

For the latest discoveries in cyber research for the week of 17th August, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES Colombia’s Ministry of Justice has experienced a ransomware attack that affected part of its technology infrastructure and disrupted public services related to illicit-drug monitoring and legal processes. Officials confirmed that some files were encrypted but stated that no data theft was detected during the incident. MyDr, Poland’s primary…

KEV ✓ EPSS 0.25 CVSS 9.8 CVE-2026-53413 CVE-2026-65400 CVE-2026-68820 CVE-2026-71362 Microsoft Apple Adobe Zoom veřejná správa zdravotnictví obrana energetika IL

Check Point Research ·

1

The Agentic AI threat cluster: Seven incidents, three actors, and what they mean for your exposure

Tenable’s Research Special Operations (RSO) team has been tracking a cluster of agentic AI threat activity since late July 2026. The Taiwan autonomous AI cyber attack confirmed what the cluster data already showed: near-autonomous offensive AI has crossed from theoretical risk to operational reality.Key TakeawaysTaiwan's Ministry of Digital Affairs confirmed a near-autonomous AI cyber attack in July 2026 in which autonomous agents mapped 21 connected government systems, compromised 85 accounts,…

KEV ✓ EPSS 1.00 CVE-2025-3248 Tenable Palo Alto Networks veřejná správa energetika US

Tenable Research ·

7

Hitachi Energy APM Edge Product

View CSAF Summary Hitachi Energy is aware of Dirty Frag vulnerabilities that affect APM Edge product versions listed in this document. Successful exploitation of these vulnerabilities could result in impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy APM Edge Product are affected: APM Edge vers:APM_Edge/<=6.10 (CVE-2026-43284, CVE-2026…

EPSS 0.93 CVSS 8.8 CVE-2026-43284 CVE-2026-43500 Hitachi Energy energetika US 2 zdrojů

CISA Advisories · Fortinet PSIRT

Haiwell IoT Cloud HMI Gateway

View CSAF Summary Successful exploitation of this vulnerability may allow an attacker to inject and execute arbitrary OS commands with root privileges. The following versions of Haiwell IoT Cloud HMI Gateway are affected: Haiwell IoT Cloud HMI Gateway 3.40.1.12 (CVE-2026-19188) CVSS Vendor Equipment Vulnerabilities v3 10 Haiwell Haiwell IoT Cloud HMI Gateway Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors:…

EPSS 0.02 CVSS 10.0 CVE-2026-19188 Haiwell energetika výroba a průmysl vodárenství US

CISA Advisories ·

AVEVA Enterprise SCADA

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to tamper with serialized data, potentially resulting in code execution during deserialization. The following versions of AVEVA Enterprise SCADA are affected: Enterprise SCADA 2025 (CVE-2025-7639) Enterprise SCADA >=2024|<=2024_SP1_P01 (CVE-2025-7639) Enterprise SCADA >=2023|<=2023_SP1 (CVE-2025-7639) Enterprise SCADA >=2022|<=2022_SP2_P2 (CVE-2025-7639) Enterprise SCADA <=2021_SP2_P5 (CVE-2025-7639)…

EPSS 0.00 CVSS 7.1 CVE-2025-7639 AVEVA výroba a průmysl energetika US

CISA Advisories ·

ANDRITZ HIPASE-250 and 250 SCALA

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to read data from the device or gain access to affected workstations. The following versions of ANDRITZ HIPASE-250 and 250 SCALA are affected: HIPASE-250 <=7.20 (CVE-2026-65309, CVE-2026-65310, CVE-2026-65311, CVE-2026-65313) 250 SCALA <=7.20 (CVE-2026-65309, CVE-2026-65310, CVE-2026-65311, CVE-2026-65313) CVSS Vendor Equipment Vulnerabilities v3 8.1 ANDRITZ ANDRITZ HIPASE-250 and 250 SCALA Storing…

EPSS 0.00 CVSS 8.1 CVE-2026-65309 CVE-2026-65310 CVE-2026-65311 CVE-2026-65313 ANDRITZ energetika US

CISA Advisories ·

Johnson Controls Metasys

View CSAF Summary Successful exploitation of this vulnerability could allow a low-privilege user or attacker to inject a persistent malicious payload via a crafted URL that executes in the context of other users' sessions, including administrators, potentially leading to session hijacking and unauthorized access. The following versions of Johnson Controls Metasys are affected: Metasys 12 vers:all/* (CVE-2026-34491) Metasys 13 vers:all/* (CVE-2026-34491) Metasys 14 Metasys 15 CVSS Vendor…

EPSS 0.00 CVSS 8.0 CVE-2026-34491 Johnson Controls energetika výroba a průmysl veřejná správa doprava US

CISA Advisories ·

Johnson Controls Inc. Airwall

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to decrypt sensitive data, bypass authentication controls, gaining unauthorized access to read arbitrary files on the system, or gain unauthorized access to protected system resources. The following versions of Johnson Controls Inc. Airwall are affected: Airwall <=4.0.4 (CVE-2026-64887, CVE-2026-34492) CVSS Vendor Equipment Vulnerabilities v3 6.8 Johnson Controls Inc. Johnson Controls Inc. Airwall Use of…

EPSS 0.00 CVSS 6.8 CVE-2026-34492 CVE-2026-64887 Johnson Controls výroba a průmysl veřejná správa energetika doprava US

CISA Advisories ·

Siemens Desigo DXR and PXC Controllers

View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo DXR and PXC Controllers are affected: Desigo DXR2 vers:intdot/<01.21.233.16-7862 …

EPSS 0.00 CVSS 4.3 CVE-2026-59693 Siemens energetika zdravotnictví výroba a průmysl doprava US

CISA Advisories ·

2

[Control Systems] Phoenix Contact security advisory (AV26-811)

Serial number: AV26-811Date: August 12, 2026 As of August 12, 2026, Phoenix Contact is affected by vulnerabilities in the following products: AXC F 1152 Prior to 2026.0.3 AXC F 1252 Prior to 2026.0.3 AXC F 2000 EA Prior to 2026.0.3 AXC F 2152 Prior to 2026.0.3 AXC F 3152 Prior to 2026.0.3 BPC 9102S Prior to 2026.0.3 BPC 9202S Prior to 2026.0.3 Catan C1 Prior to 2026.0.3 EPC 1502 Prior to 2026.0.3 EPC 1522 Prior to 2026.0.3 RFC 4072R Prior to 2026.0.3 RFC 4072S Prior to 2026.0.3 VL3 UPC 2440…

Phoenix Contact výroba a průmysl energetika vodárenství CA

Cyber Centre Kanada ·

Siemens RUGGEDCOM APE1808

View CSAF Summary Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens recommends to contact customer support for additional information, and follow Fortinet advisory for workarounds and mitigation measures. The following versions of Siemens RUGGEDCOM APE1808 are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-23573, CVE-2026-59839) CVSS Vendor Equipment Vulnerabilities v3 6.1 Siemens Siemens RUGGEDCOM APE1808…

EPSS 0.00 CVSS 6.1 CVE-2026-23573 CVE-2026-59839 Siemens Fortinet výroba a průmysl energetika doprava US

CISA Advisories ·

2

Aggiornamenti per prodotti Siemens

Siemens ha rilasciato aggiornamenti di sicurezza per sanare molteplici vulnerabilità nei propri prodotti, di cui 1 con gravità “critica” e 13 con gravità “alta”. Tali vulnerabilità, qualora sfruttate, potrebbero consentire ad un utente malintenzionato di eseguire codice arbitrario e di leggere file arbitrari sul filesystem dei sistemi interessati.

EPSS 0.01 CVE-2026-50058 CVE-2026-50059 CVE-2026-50060 CVE-2026-50061 CVE-2026-50062 CVE-2026-50063 CVE-2026-50064 CVE-2026-58115 CVE-2026-59086 CVE-2026-59700 CVE-2026-59701 CVE-2026-64629 CVE-2026-69108 CVE-2026-69109 Siemens výroba a průmysl energetika IT

CSIRT Itálie (ACN) ·

Head Mare APT is exploiting vulnerabilities in an unpatched TrueConf server to deliver PhantomCore and PhantomGraph to video conference participants

Overview of the attack In July 2026, Kaspersky experts detected a new attack by the Head Mare group. Previously, we classified them as hacktivists, but now we define them as an APT group due to the sophistication of their TTPs and the absence of destructive activity (encryption, wiping) in the targeted infrastructures. In this latest campaign, the attackers exploited a chain of vulnerabilities in the TrueConf video conferencing server and replaced the original TrueConf client installers with…

TrueConf Kaspersky Microsoft energetika výroba a průmysl doprava telekomunikace RU

Securelist (Kaspersky) ·

2

DeadLock ransomware: Breaking down a Rust-based encryptor with decentralized recovery infrastructure

In this article Pre-encryptionEncryptionPost-encryptionDefending against DeadLock ransomwareIndicators of compromise Microsoft Threat Intelligence tracks DeadLock ransomware as an emerging financially motivated operation distinguished by its use of decentralized infrastructure to support victim communications and data leak operations. Its recovery ecosystem combines the Session messaging network with blockchain-backed services that store and deliver resources used throughout the extortion…

Microsoft doprava výroba a průmysl energetika US

Microsoft Security Blog ·

#StopRansomware: Gunra Ransomware

Advisory at a Glance Title #StopRansomware: Gunra Ransomware Original Publication August 10, 2026 Executive Summary Gunra is a ransomware-as-a-service (RaaS) used by affiliates to target government, critical infrastructure, and other organizations. The Gunra ransomware variant first appeared in 2025 and expanded to RaaS operations in 2026. The actors leverage a double-extortion model, both encrypting data and threatening to publish exfiltrated data to a dedicated leak site (DLS) if the ransom…

KEV ✓ EPSS 0.98 CVE-2024-55591 CVE-2025-24472 veřejná správa zdravotnictví finance energetika US

CISA Advisories ·

1

Follow-Up Report of the December 2025 Energy Sector Incident

During the attacks against Poland's energy sector in late 2025, a second combined heat and power plant was also affected. We are publishing a report detailing an investigation that lasted more than three months and led to the discovery of a previously unobserved attack vector involving a private APN.

energetika PL

CERT Polska ·

2

Johnson Controls Inc. TL280

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to access sensitive information on the device. The following versions of Johnson Controls Inc. TL280 are affected: TL280 <5.63 (CVE-2026-27871) CVSS Vendor Equipment Vulnerabilities v3 4.1 Johnson Controls Inc. Johnson Controls Inc. TL280 Use of a Broken or Risky Cryptographic Algorithm Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and…

EPSS 0.00 CVSS 4.1 CVE-2026-27871 Johnson Controls energetika výroba a průmysl veřejná správa doprava US

CISA Advisories ·

ABB Ability Zenon

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to bypass security, crash systems, execute unauthorized actions, or compromise data. The following versions of ABB Ability Zenon are affected: IIoT services with MongoDB (4.2) installed on ABB Ability Zenon vers:all/* CVSS Vendor Equipment Vulnerabilities v3 7.8 ABB ABB Ability Zenon Improper Handling of Length Parameter Inconsistency, Improper Neutralization of Null Byte or NUL Character, Collapse of Data…

KEV ✓ EPSS 0.83 CVSS 7.8 CVE-2020-7921 CVE-2020-7928 CVE-2025-14847 ABB energetika zdravotnictví vodárenství výroba a průmysl US

CISA Advisories ·

11

Canada’s Bill C-8 is here: Why the 72-hour reporting rule will redefine critical infrastructure security

Canada’s new Critical Cyber Systems Protection Act (Bill C-8) introduces a strict 72-hour cyber incident reporting mandate. Find out how Tenable is helping critical national infrastructure operators bridge the IT/OT divide to ensure full compliance.Key takeaways:Bill C-8 introduces stringent new cyber incident reporting requirements and heavy financial penalties for critical infrastructure operators. Eliminating network blind spots with a hybrid IT/OT discovery approach, including Safe Active…

Tenable veřejná správa energetika telekomunikace doprava US

Tenable Research ·

Kritická zranitelnost v systému Siemens Desigo CC

Společnost Siemens vydala bezpečnostní aktualizace pro systém Desigo CC. Opravy řeší kritickou zranitelnost (CVSS 9.8), jejíž zneužití může umožnit vzdálené spuštění kódu nebo způsobit nedostupnost systému. Zranitelnost se týká organizací využívajících systém Siemens Desigo CC pro řízení budov (Building Management System - BMS). Provozovatelům se doporučuje co nejdříve nainstalovat dostupné bezpečnostní aktualizace a zajistit, aby systémy nebyly přímo dostupné z internetu, ale byly chráněny…

CVSS 9.8 Siemens energetika výroba a průmysl CZ

CSIRT.CZ (CZ.NIC) ·

ZDI-26-505: (Pwn2Own) Phoenix Contact CHARX SEC-3150 charx-system-config-manager Service CRLF Injection Firewall Bypass Vulnerability

This vulnerability allows network-adjacent attackers to bypass firewall rules on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 5.0. The following CVEs are assigned: CVE-2026-44092.

EPSS 0.00 CVSS 5.0 CVE-2026-44092 Phoenix Contact energetika US

Zero Day Initiative ·

ZDI-26-506: (Pwn2Own) Phoenix Contact CHARX SEC-3150 Insertion of Sensitive Information into Log File Authentication Bypass Vulnerability

This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 5.3. The following CVEs are assigned: CVE-2026-44105.

EPSS 0.00 CVSS 5.3 CVE-2026-44105 Phoenix Contact energetika US

Zero Day Initiative ·

ZDI-26-507: (Pwn2Own) Phoenix Contact CHARX SEC-3150 Privilege Defined With Unsafe Actions Local Privilege Escalation Vulnerability

This vulnerability allows local attackers to escalate privileges on affected installations of Phoenix Contact CHARX SEC-3150 devices. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2026-44096.

EPSS 0.00 CVSS 7.8 CVE-2026-44096 Phoenix Contact energetika US

Zero Day Initiative ·

ZDI-26-509: (Pwn2Own) Phoenix Contact CHARX SEC-3150 OCPP Missing Authentication for Critical Function Authentication Bypass Vulnerability

This vulnerability allows network-adjacent attackers to modify configuration on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 5.0. The following CVEs are assigned: CVE-2026-44101.

EPSS 0.00 CVSS 5.0 CVE-2026-44101 Phoenix Contact energetika US

Zero Day Initiative ·

ZDI-26-510: (Pwn2Own) Phoenix Contact CHARX SEC-3150 Missing Cryptographic Signature Remote Code Execution Vulnerability

This vulnerability allows network-adjacent attackers to bypass firmware validation on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.5. The following CVEs are assigned: CVE-2026-44104.

EPSS 0.00 CVSS 7.5 CVE-2026-44104 Phoenix Contact energetika US

Zero Day Initiative ·

ZDI-26-512: (Pwn2Own) Phoenix Contact CHARX SEC-3150 ModBus Server Exposed Dangerous Function Denial-of-Service Vulnerability

This vulnerability allows network-adjacent attackers to create a denial-of-service condition on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 6.5. The following CVEs are assigned: CVE-2026-44107.

EPSS 0.00 CVSS 6.5 CVE-2026-44107 Phoenix Contact energetika US

Zero Day Initiative ·

ZDI-26-513: (Pwn2Own) Phoenix Contact CHARX SEC-3150 update2-upload Arbitrary File Upload Vulnerability

This vulnerability allows network-adjacent attackers to upload arbitrary files on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 2.4. The following CVEs are assigned: CVE-2026-44097.

EPSS 0.00 CVSS 2.4 CVE-2026-44097 Phoenix Contact energetika US

Zero Day Initiative ·

ZDI-26-514: (Pwn2Own) Phoenix Contact CHARX SEC-3150 Failing Open Authentication Bypass Vulnerability

This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.5. The following CVEs are assigned: CVE-2026-44094.

EPSS 0.00 CVSS 7.5 CVE-2026-44094 Phoenix Contact energetika US

Zero Day Initiative ·

ZDI-26-515: (Pwn2Own) Phoenix Contact CHARX SEC-3150 charx-jupicore Missing Authentication Configuration Modification Vulnerability

This vulnerability allows network-adjacent attackers to modify configuration on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 4.2. The following CVEs are assigned: CVE-2026-44100.

EPSS 0.00 CVSS 4.2 CVE-2026-44100 Phoenix Contact energetika US

Zero Day Initiative ·