View CSAF Summary Successful exploitation of this vulnerability could result in memory corruption, a device crash, or a potential remote attack vector without the originating device receiving a CIP error indicating that the request could not be processed. The following versions of Pyramid Solutions NetStaX EtherNet/IP Stack are affected: EtherNet/IP Adapter DLL Kit (EIPA) EtherNet/IP Adapter DLL Kit with CIP Security (EIPA-SECURE) EtherNet/IP Adapter Development Kit (EADK) EtherNet/IP Adapter…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to perform remote code execution on the computer running the client with elevated privileges. The following versions of IXON VPN Client are affected: VPN Client <1.4.7 (CVE-2026-75925) CVSS Vendor Equipment Vulnerabilities v3 9.6 IXON IXON VPN Client Improper Neutralization of CRLF Sequences ('CRLF Injection') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy,…
View CSAF Summary Successful exploitation of this vulnerability could give an attacker the ability to run any commands or code of the attacker's choice on a target machine at the logged-in user's permission level. The following versions of Rockwell Automation ControlFLASH are affected: ControlFLASH <=V15.07 (CVE-2026-12663) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation ControlFLASH Missing Authentication for Critical Function Background Critical…
View CSAF Summary Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra…
View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to perform a man-in-the-middle (MitM) attack, cause a factory reset, wipe credentials, or retrieve sensitive information. The following versions of Tycon Systems TPDIN-Monitor-WEB3 are affected: TPDIN-Monitor-WEB3 <=2.2.9 (CVE-2026-77847, CVE-2026-82712, CVE-2026-82684) CVSS Vendor Equipment Vulnerabilities v3 8.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB3 Use of Hard-coded Credentials, Cross-Site…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to take control of a high-privilege terminal during installation and run arbitrary commands. The following versions of OPCFoundation OPC UA LocalDiscoveryServer (LDS) are affected: UA-LDS-Installers <1.04.420 (CVE-2026-77477) CVSS Vendor Equipment Vulnerabilities v3 4.6 OPCFoundation OPCFoundation OPC UA LocalDiscoveryServer (LDS) Execution with Unnecessary Privileges Background Critical Infrastructure…
View CSAF Summary Successful exploitation of this vulnerability could allow any authenticated user to create projects. The following versions of Inductive Automation Ignition are affected: Ignition <=8.1.53 (CVE-2026-77393) CVSS Vendor Equipment Vulnerabilities v3 8.8 Inductive Automation Inductive Automation Ignition Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company…
Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.8, CVEs: CVE-2026-20212, Summary: A vulnerability in the Silicon One integration for Cisco Nexus 9000 Series Switches could allow an unauthenticated, remote attacker to execute code with root privileges. This vulnerability exists because TCP ports 43210 and 43211 are accessible in the default Layer 3 (L3) virtual routing and forwarding (VRF). A successful exploit could allow the attacker to connect to…
Serial Number: AV26-871Date: September 2, 2026 As of September 1, 2026, Schneider Electric is affected by vulnerabilities in the following products: NetBotz 5 - 750/755 Versions prior to or equal to 5.5.2 PowerChute Serial Shutdown Versions prior to or equal to 1.5 The Cyber Centre encourages users and administrators to review the provided web links, perform the suggested mitigations and apply the necessary updates. Multiple Vulnerabilities on NetBotz 5 - 750/755 Products Improper Restriction…
View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to escalate and execute processes with administrator privileges. The following versions of Rockwell Automation Redundancy Module Configuration Tool are affected: Redundancy Module Configuration Tool 10.00.00 (CVE-2026-9633) Redundancy Module Configuration Tool >=9.00.00|<=10.00.00 (CVE-2026-9634) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation Redundancy Module…
View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed; an out-of-bounds write condition may allow remote code execution. The following versions of Rockwell Automation Historian ME are affected: Series B 5.202 (CVE-2025-12768, CVE-2026-12661) Series C 7.101 (CVE-2025-12768, CVE-2026-12661) CVSS Vendor Equipment Vulnerabilities v3 8 Rockwell Automation Rockwell Automation Historian ME Out-of-bounds Write, Stack-based Buffer Overflow Background…
Serial Number: AV26-864Date: August 31, 2026 As of August 27, 2026, Siemens is affected by a vulnerability in the following products: Element maps-ng V47 Prior to V47.12.3 Element maps-ng V48 Prior to V48.11.3 Element maps-ng V49 Prior to V49.16.1 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. SSA-682041 CERT Services | Siemens
Serial Number: AV26-856Date: August 28, 2026 As of August 25, 2026, National Instruments is affected by vulnerabilities in the following product: LabVIEW Prior to 23.0.0 Prior to 23.3.10 Prior to 24.3.7 Prior to 25.3.5 Prior to 26.3.1 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. Memory Corruption Vulnerabilities in NI LabVIEW - NI Integer Conversion Vulnerability Resulting in an Out of Bounds Read…
The Trump administration is banning the acquisition of foreign-made components used to manage electricity and power, alleging that “certain foreign actors are increasingly creating and exploiting vulnerabilities” in the technology.
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to read or write arbitrary local files, cause the application to issue outbound network requests, or intercept the connection to impersonate the trusted peer, complete the TLS handshake, and read or modify the protected communications. The following versions of Applied Systems Engineering ASE2000 V2 Communications Test Set are affected: ASE2000 >=2.25|<=2.37 (CVE-2018-1285, CVE-2026-18717) CVSS Vendor…
All threats In Q2 2026, the percentage of ICS computers on which malicious objects were blocked continued to decrease, falling to 19.15%, its lowest level since 2022. Percentage of ICS computers on which malicious objects were blocked, Q3 2023–Q2 2026 Regionally, the percentages ranged from 8.1% in Northern Europe to 27.9% in Africa. Regions ranked by percentage of attacked ICS computers The figures increased in five regions over the quarter, most notably in East Asia (by 2.0 pp) and Africa (by…
Classification: Severe, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.3, CVEs: CVE-2026-15203, Summary: Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanism
Národné centrum kybernetickej bezpečnosti (NCKB) NBÚ upozorňuje na nebezpečenstvo prevádzkovania programovateľných logických radičov (ďalej ako „PLC“) voľne dostupných z verejného internetu. PLC nie je zariadenie, ktoré má byť priamo dostupné z verejného internetu. Programovateľné logické radiče hrajú kľúčovú úlohu takmer vo všetkých odvetviach priemyslu. Ich vystavenie do verejného internetu môže viesť k ohrozeniu útočníkmi s... The post PLC na internete: aktuálne riziko aj pre kritickú…
View CSAF Summary SIMATIC IoT2050 Advanced devices running Industrial OS with Node-RED installed contain a missing authentication vulnerability in the Node-RED HTTP interface that could allow an unauthenticated remote attacker to create malicious flows and execute arbitrary code on the underlying server with maximum privileges. Siemens has released a new version for SIMATIC IoT2050 Advanced and strongly recommends to update to the latest version. The following versions of Siemens SIMATIC…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized administrative access, disclose sensitive information, modify device configuration, hijack authenticated sessions, and disrupt device operation. The following versions of Ebyte NE2-D11 are affected: NE2-D11 Firmware FW-9167-0-11 CVSS Vendor Equipment Vulnerabilities v3 9.8 Ebyte Ebyte NE2-D11 Missing Authentication for Critical Function, Cleartext Transmission of Sensitive Information…
For the latest discoveries in cyber research for the week of 24th August, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES Latvia’s Road Traffic Safety Directorate (CSDD) has confirmed a breach affecting payment records of more than 1.2 million people – roughly two-thirds of the country’s population – as well as 200,000 organizations. The stolen data included identification numbers, license plates, payment amounts, dates and addresses. Attackers reportedly exploited a…
Classification: Important, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 5.3, CVEs: CVE-2026-27875, Summary: CISA released one Industrial Control Systems (ICS) Advisory. This advisory provides timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-26-232-01 Johnson Controls Simplex Incident Manager
A joint cybersecurity advisory released by multiple U.S. government agencies warns that threat actors are using AI-generated exploitation scripts to target exposed Siemens S7 Series PLCs across critical infrastructure sectors.Key TakeawaysUnattributed threat actors are exploiting known weaknesses and unnecessary internet exposure to conduct reconnaissance and possible pre-positioning for future disruptive attacks against Siemens S7 Series PLCs.The attackers are leveraging AI to build and refine…
The National Security Agency (NSA), FBI and other federal agencies said the campaign is targeting Siemens S7 Series PLCs and was being fueled by “AI-assisted development” alongside exploitation of known vulnerabilities.
U.S. cybersecurity agencies warn that threat actors are using AI-generated scripts to exploit Siemens S7 Series programmable logic controllers (PLCs) in U.S. critical infrastructure. [...]
Executive summary Note: This advisory relates to an active threat to Siemens S7 Series programmable logic controllers (PLCs). However, ongoing PLC targeting activity is broader than Siemens PLCs. All PLC owners and operators should apply relevant mitigations to reduce the risk to their devices and systems. The Siemens-specific content in this advisory should be understood and applied as one subset of the wider threat landscape. Top Mitigations Inventory all Siemens S7 Series programmable logic…
The FBI said Tuesday that the Medusa ransomware gang has breached more than 500 critical infrastructure organizations in the United States since June 2021. [...]
The Cybersecurity and Infrastructure Security Agency (CISA) and FBI updated an advisory on the group initially released in March 2025 — writing that as of April 2026, Medusa actors have hit more than 500 victims. CISA previously said 300 victims, many of which are in critical infrastructure sectors, were attacked as of 2025.
View CSAF Summary Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released new versions for the affected products and recommends to update to the latest versions. The…
For the latest discoveries in cyber research for the week of 17th August, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES Colombia’s Ministry of Justice has experienced a ransomware attack that affected part of its technology infrastructure and disrupted public services related to illicit-drug monitoring and legal processes. Officials confirmed that some files were encrypted but stated that no data theft was detected during the incident. MyDr, Poland’s primary…
Tenable’s Research Special Operations (RSO) team has been tracking a cluster of agentic AI threat activity since late July 2026. The Taiwan autonomous AI cyber attack confirmed what the cluster data already showed: near-autonomous offensive AI has crossed from theoretical risk to operational reality.Key TakeawaysTaiwan's Ministry of Digital Affairs confirmed a near-autonomous AI cyber attack in July 2026 in which autonomous agents mapped 21 connected government systems, compromised 85 accounts,…
View CSAF Summary Hitachi Energy is aware of Dirty Frag vulnerabilities that affect APM Edge product versions listed in this document. Successful exploitation of these vulnerabilities could result in impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy APM Edge Product are affected: APM Edge vers:APM_Edge/<=6.10 (CVE-2026-43284, CVE-2026…
View CSAF Summary Successful exploitation of this vulnerability may allow an attacker to inject and execute arbitrary OS commands with root privileges. The following versions of Haiwell IoT Cloud HMI Gateway are affected: Haiwell IoT Cloud HMI Gateway 3.40.1.12 (CVE-2026-19188) CVSS Vendor Equipment Vulnerabilities v3 10 Haiwell Haiwell IoT Cloud HMI Gateway Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors:…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to tamper with serialized data, potentially resulting in code execution during deserialization. The following versions of AVEVA Enterprise SCADA are affected: Enterprise SCADA 2025 (CVE-2025-7639) Enterprise SCADA >=2024|<=2024_SP1_P01 (CVE-2025-7639) Enterprise SCADA >=2023|<=2023_SP1 (CVE-2025-7639) Enterprise SCADA >=2022|<=2022_SP2_P2 (CVE-2025-7639) Enterprise SCADA <=2021_SP2_P5 (CVE-2025-7639)…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to read data from the device or gain access to affected workstations. The following versions of ANDRITZ HIPASE-250 and 250 SCALA are affected: HIPASE-250 <=7.20 (CVE-2026-65309, CVE-2026-65310, CVE-2026-65311, CVE-2026-65313) 250 SCALA <=7.20 (CVE-2026-65309, CVE-2026-65310, CVE-2026-65311, CVE-2026-65313) CVSS Vendor Equipment Vulnerabilities v3 8.1 ANDRITZ ANDRITZ HIPASE-250 and 250 SCALA Storing…
View CSAF Summary Successful exploitation of this vulnerability could allow a low-privilege user or attacker to inject a persistent malicious payload via a crafted URL that executes in the context of other users' sessions, including administrators, potentially leading to session hijacking and unauthorized access. The following versions of Johnson Controls Metasys are affected: Metasys 12 vers:all/* (CVE-2026-34491) Metasys 13 vers:all/* (CVE-2026-34491) Metasys 14 Metasys 15 CVSS Vendor…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to decrypt sensitive data, bypass authentication controls, gaining unauthorized access to read arbitrary files on the system, or gain unauthorized access to protected system resources. The following versions of Johnson Controls Inc. Airwall are affected: Airwall <=4.0.4 (CVE-2026-64887, CVE-2026-34492) CVSS Vendor Equipment Vulnerabilities v3 6.8 Johnson Controls Inc. Johnson Controls Inc. Airwall Use of…
View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo DXR and PXC Controllers are affected: Desigo DXR2 vers:intdot/<01.21.233.16-7862 …
Serial number: AV26-811Date: August 12, 2026 As of August 12, 2026, Phoenix Contact is affected by vulnerabilities in the following products: AXC F 1152 Prior to 2026.0.3 AXC F 1252 Prior to 2026.0.3 AXC F 2000 EA Prior to 2026.0.3 AXC F 2152 Prior to 2026.0.3 AXC F 3152 Prior to 2026.0.3 BPC 9102S Prior to 2026.0.3 BPC 9202S Prior to 2026.0.3 Catan C1 Prior to 2026.0.3 EPC 1502 Prior to 2026.0.3 EPC 1522 Prior to 2026.0.3 RFC 4072R Prior to 2026.0.3 RFC 4072S Prior to 2026.0.3 VL3 UPC 2440…
View CSAF Summary Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens recommends to contact customer support for additional information, and follow Fortinet advisory for workarounds and mitigation measures. The following versions of Siemens RUGGEDCOM APE1808 are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-23573, CVE-2026-59839) CVSS Vendor Equipment Vulnerabilities v3 6.1 Siemens Siemens RUGGEDCOM APE1808…
Siemens ha rilasciato aggiornamenti di sicurezza per sanare molteplici vulnerabilità nei propri prodotti, di cui 1 con gravità “critica” e 13 con gravità “alta”. Tali vulnerabilità, qualora sfruttate, potrebbero consentire ad un utente malintenzionato di eseguire codice arbitrario e di leggere file arbitrari sul filesystem dei sistemi interessati.
Overview of the attack In July 2026, Kaspersky experts detected a new attack by the Head Mare group. Previously, we classified them as hacktivists, but now we define them as an APT group due to the sophistication of their TTPs and the absence of destructive activity (encryption, wiping) in the targeted infrastructures. In this latest campaign, the attackers exploited a chain of vulnerabilities in the TrueConf video conferencing server and replaced the original TrueConf client installers with…
In this article Pre-encryptionEncryptionPost-encryptionDefending against DeadLock ransomwareIndicators of compromise Microsoft Threat Intelligence tracks DeadLock ransomware as an emerging financially motivated operation distinguished by its use of decentralized infrastructure to support victim communications and data leak operations. Its recovery ecosystem combines the Session messaging network with blockchain-backed services that store and deliver resources used throughout the extortion…
Advisory at a Glance Title #StopRansomware: Gunra Ransomware Original Publication August 10, 2026 Executive Summary Gunra is a ransomware-as-a-service (RaaS) used by affiliates to target government, critical infrastructure, and other organizations. The Gunra ransomware variant first appeared in 2025 and expanded to RaaS operations in 2026. The actors leverage a double-extortion model, both encrypting data and threatening to publish exfiltrated data to a dedicated leak site (DLS) if the ransom…
During the attacks against Poland's energy sector in late 2025, a second combined heat and power plant was also affected. We are publishing a report detailing an investigation that lasted more than three months and led to the discovery of a previously unobserved attack vector involving a private APN.
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to access sensitive information on the device. The following versions of Johnson Controls Inc. TL280 are affected: TL280 <5.63 (CVE-2026-27871) CVSS Vendor Equipment Vulnerabilities v3 4.1 Johnson Controls Inc. Johnson Controls Inc. TL280 Use of a Broken or Risky Cryptographic Algorithm Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and…
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to bypass security, crash systems, execute unauthorized actions, or compromise data. The following versions of ABB Ability Zenon are affected: IIoT services with MongoDB (4.2) installed on ABB Ability Zenon vers:all/* CVSS Vendor Equipment Vulnerabilities v3 7.8 ABB ABB Ability Zenon Improper Handling of Length Parameter Inconsistency, Improper Neutralization of Null Byte or NUL Character, Collapse of Data…
Canada’s new Critical Cyber Systems Protection Act (Bill C-8) introduces a strict 72-hour cyber incident reporting mandate. Find out how Tenable is helping critical national infrastructure operators bridge the IT/OT divide to ensure full compliance.Key takeaways:Bill C-8 introduces stringent new cyber incident reporting requirements and heavy financial penalties for critical infrastructure operators. Eliminating network blind spots with a hybrid IT/OT discovery approach, including Safe Active…
Společnost Siemens vydala bezpečnostní aktualizace pro systém Desigo CC. Opravy řeší kritickou zranitelnost (CVSS 9.8), jejíž zneužití může umožnit vzdálené spuštění kódu nebo způsobit nedostupnost systému. Zranitelnost se týká organizací využívajících systém Siemens Desigo CC pro řízení budov (Building Management System - BMS). Provozovatelům se doporučuje co nejdříve nainstalovat dostupné bezpečnostní aktualizace a zajistit, aby systémy nebyly přímo dostupné z internetu, ale byly chráněny…
This vulnerability allows network-adjacent attackers to bypass firewall rules on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 5.0. The following CVEs are assigned: CVE-2026-44092.
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 5.3. The following CVEs are assigned: CVE-2026-44105.
This vulnerability allows local attackers to escalate privileges on affected installations of Phoenix Contact CHARX SEC-3150 devices. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2026-44096.
This vulnerability allows network-adjacent attackers to modify configuration on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 5.0. The following CVEs are assigned: CVE-2026-44101.
This vulnerability allows network-adjacent attackers to bypass firmware validation on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.5. The following CVEs are assigned: CVE-2026-44104.
This vulnerability allows network-adjacent attackers to create a denial-of-service condition on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 6.5. The following CVEs are assigned: CVE-2026-44107.
This vulnerability allows network-adjacent attackers to upload arbitrary files on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 2.4. The following CVEs are assigned: CVE-2026-44097.
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.5. The following CVEs are assigned: CVE-2026-44094.
This vulnerability allows network-adjacent attackers to modify configuration on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 4.2. The following CVEs are assigned: CVE-2026-44100.