Výsledky hledání

výrobce: Siemens v celém archivu

Různé zkratky a hodnoty pod každou zprávou mají svoji legendu — pokud na údaji postojíte myší. Některé jsou klikatelné. Typicky CVE.

zrušit filtry CZ · EN/orig

16 karet z 16 položek

1

CISA Releases Two Industrial Control Systems Advisories

Classification: Important, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 8.8, CVEs: CVE-2026-63133, CVE-2026-63134, CVE-2026-55676, CVE-2026-63177, CVE-2026-19670, CVE-2026-19671, CVE-2026-59086, Summary: CISA released two Industrial Control Systems (ICS) Advisories. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-26-230-01 CISA Malcolm ICSA-26-230-02 Siemens Simcenter Nastran

EPSS 0.00 CVSS 8.8 CVE-2026-19670 CVE-2026-19671 CVE-2026-55676 CVE-2026-59086 CVE-2026-63133 CVE-2026-63134 CVE-2026-63177 Siemens výroba a průmysl FI

NCSC-FI ·

1

Siemens Simcenter Nastran

View CSAF Summary Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released new versions for the affected products and recommends to update to the latest versions. The…

EPSS 0.00 CVSS 7.8 CVE-2026-59086 Siemens výroba a průmysl obrana energetika zdravotnictví US

CISA Advisories ·

7

Siemens Simcenter Femap

View CSAF Summary Simcenter Femap contains two file parsing vulnerabilities that could be triggered when the application reads files in BMP file format. If a user is tricked to open a malicious file with the affected application, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version. The following versions of Siemens Simcenter Femap are affected: Simcenter…

EPSS 0.00 CVSS 7.8 CVE-2026-59700 CVE-2026-59701 Siemens výroba a průmysl US

CISA Advisories ·

Siemens Solid Edge

View CSAF Summary Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Solid Edge are affected: Solid Edge SE2025 vers:intdot/<225.0.15 (CVE-2026-50058, CVE-2026…

EPSS 0.00 CVSS 7.8 CVE-2026-50058 CVE-2026-50059 CVE-2026-50060 CVE-2026-50061 CVE-2026-50062 CVE-2026-50063 CVE-2026-50064 Siemens výroba a průmysl US

CISA Advisories ·

Siemens LOGO! Soft Comfort

View CSAF Summary Siemens LOGO! Soft Comfort contains multiple vulnerabilities in its project-file encryption and password handling mechanisms. A local attacker could exploit these vulnerabilities to extract the master key, allowing them to decrypt project data or remove project passwords. The lack of password salting enables offline dictionary or brute-force attacks against the password hashes. Successful exploitation could result in unauthorized access to, or modification of, sensitive…

EPSS 0.00 CVSS 6.8 CVE-2026-57262 CVE-2026-57263 Siemens výroba a průmysl doprava US

CISA Advisories ·

Siemens Siveillance Video

View CSAF Summary Siveillance Video Management Servers contains a vulnerability that could allow a Remote Code Execution attack. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Siveillance Video are affected: Siveillance Video V2023 R3 vers:intdot/<23.3.27 (CVE-2026-3014) Siveillance Video V2024 R1 vers:intdot/<24.1.16 (CVE-2026-3014) Siveillance Video V2025 vers:intdot/<25.1.15 (CVE-2026-3014) CVSS…

EPSS 0.01 CVSS 9.1 CVE-2026-3014 Siemens výroba a průmysl telekomunikace US

CISA Advisories ·

Siemens Desigo DXR and PXC Controllers

View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo DXR and PXC Controllers are affected: Desigo DXR2 vers:intdot/<01.21.233.16-7862 …

EPSS 0.00 CVSS 4.3 CVE-2026-59693 Siemens energetika zdravotnictví výroba a průmysl doprava US

CISA Advisories ·

Siemens License Server (SLS)

View CSAF Summary Siemens License Server is affected by multiple vulnerabilities which could allow an attacker to elevate its privileges and read arbitrary files on the system. Siemens has released a new version for Siemens License Server (SLS) and recommends to update to the latest version. The following versions of Siemens License Server (SLS) are affected: Siemens License Server (SLS) vers:intdot/<5.1, vers:intdot/<5.3 (CVE-2026-69108, CVE-2026-69109) CVSS Vendor Equipment Vulnerabilities v3…

EPSS 0.00 CVSS 7.5 CVE-2026-69108 CVE-2026-69109 Siemens US

CISA Advisories ·

Siemens Parasolid

View CSAF Summary Parasolid is affected by an out of bounds read vulnerability that could be triggered when the application reads files in X_T format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Parasolid are affected: Parasolid V38.0 vers:intdot/<38.0.235 (CVE-2026-64629) Parasolid V38.1 vers:intdot/<38.1.230 (CVE…

EPSS 0.00 CVSS 7.8 CVE-2026-64629 Siemens výroba a průmysl US

CISA Advisories ·

2

Siemens RUGGEDCOM APE1808

View CSAF Summary Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens recommends to contact customer support for additional information, and follow Fortinet advisory for workarounds and mitigation measures. The following versions of Siemens RUGGEDCOM APE1808 are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-23573, CVE-2026-59839) CVSS Vendor Equipment Vulnerabilities v3 6.1 Siemens Siemens RUGGEDCOM APE1808…

EPSS 0.00 CVSS 6.1 CVE-2026-23573 CVE-2026-59839 Siemens Fortinet výroba a průmysl energetika doprava US

CISA Advisories ·

2

[Control systems] Siemens security advisory (AV26-802)

Serial Number: AV26-802Date: August 11, 2026 As of August 11, 2026, Siemens is affected by vulnerabilities in the following products: Desigo DXR2 Prior to V01.21.233.16-7862 Desigo PXC3 Prior to V01.21.233.16-7862 Desigo PXC4 Prior to V02.21.194.36-2715 Desigo PXC5.E003 Prior to V02.21.194.36-2715 Desigo PXC5.E24 Prior to V02.21.194.36-2715 Desigo PXC7 Prior to V02.21.194.36-2715 LOGO! Soft Comfort Prior to V9 Parasolid V38.0 Prior to V38.0.235 Parasolid V38.1 Prior to V38.1.230 SIMATIC IoT2050…

Siemens výroba a průmysl CA

Cyber Centre Kanada ·

Aggiornamenti per prodotti Siemens

Siemens ha rilasciato aggiornamenti di sicurezza per sanare molteplici vulnerabilità nei propri prodotti, di cui 1 con gravità “critica” e 13 con gravità “alta”. Tali vulnerabilità, qualora sfruttate, potrebbero consentire ad un utente malintenzionato di eseguire codice arbitrario e di leggere file arbitrari sul filesystem dei sistemi interessati.

Siemens výroba a průmysl energetika IT

CSIRT Itálie (ACN) ·

1

Kritická zranitelnost v systému Siemens Desigo CC

Společnost Siemens vydala bezpečnostní aktualizace pro systém Desigo CC. Opravy řeší kritickou zranitelnost (CVSS 9.8), jejíž zneužití může umožnit vzdálené spuštění kódu nebo způsobit nedostupnost systému. Zranitelnost se týká organizací využívajících systém Siemens Desigo CC pro řízení budov (Building Management System - BMS). Provozovatelům se doporučuje co nejdříve nainstalovat dostupné bezpečnostní aktualizace a zajistit, aby systémy nebyly přímo dostupné z internetu, ale byly chráněny…

CVSS 9.8 Siemens energetika výroba a průmysl CZ

CSIRT.CZ (CZ.NIC) ·

1

Coordinated "cyberattack" on U.S. water utilities: What you need to know

A coordinated cyber attack disrupted water and wastewater systems in at least 12 U.S. states, including more than 30 Minnesota communities. Here is what defenders need to know about the attack so far. This FAQ also details recent cyberactivity targeting internet-exposed PLCs, and how to protect exposed infrastructure.Change logUpdate August 10: Added Columbus Water Works as a second confirmed Georgia victim. Added a table summarizing publicly confirmed affected entities to date.This is an…

KEV ✓ EPSS 0.61 CVSS 9.8 CVE-2021-22681 Rockwell Automation Schneider Electric Siemens vodárenství US

Tenable Research ·

1