A custom Java web shell likely linked to the Clop ransomware gang was designed specifically for PTC Windchill and FlexPLM servers, with built-in features to decrypt credentials, enumerate file repositories, and steal files. [...]
You can’t patch everything. So what do you fix first? Findings in Q2 2026 have changed traditional answers.The latest Quarterly Threat Landscape Report from Rapid7 Labs shows vulnerability disclosures still surging while attackers use automation and AI-assisted tooling to compress the time between disclosure and exploitation. The gap that patch cycles were built to fill is closing. Speed and volume are overwhelming security teams that have relied on traditional patch cycles and reactive…
View CSAF Summary Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released new versions for the affected products and recommends to update to the latest versions. The…
View CSAF Summary Successful exploitation of this vulnerability may allow an attacker to inject and execute arbitrary OS commands with root privileges. The following versions of Haiwell IoT Cloud HMI Gateway are affected: Haiwell IoT Cloud HMI Gateway 3.40.1.12 (CVE-2026-19188) CVSS Vendor Equipment Vulnerabilities v3 10 Haiwell Haiwell IoT Cloud HMI Gateway Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors:…
View CSAF Summary Simcenter Femap contains two file parsing vulnerabilities that could be triggered when the application reads files in BMP file format. If a user is tricked to open a malicious file with the affected application, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version. The following versions of Siemens Simcenter Femap are affected: Simcenter…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to tamper with serialized data, potentially resulting in code execution during deserialization. The following versions of AVEVA Enterprise SCADA are affected: Enterprise SCADA 2025 (CVE-2025-7639) Enterprise SCADA >=2024|<=2024_SP1_P01 (CVE-2025-7639) Enterprise SCADA >=2023|<=2023_SP1 (CVE-2025-7639) Enterprise SCADA >=2022|<=2022_SP2_P2 (CVE-2025-7639) Enterprise SCADA <=2021_SP2_P5 (CVE-2025-7639)…
View CSAF Summary Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Solid Edge are affected: Solid Edge SE2025 vers:intdot/<225.0.15 (CVE-2026-50058, CVE-2026…
View CSAF Summary Siemens LOGO! Soft Comfort contains multiple vulnerabilities in its project-file encryption and password handling mechanisms. A local attacker could exploit these vulnerabilities to extract the master key, allowing them to decrypt project data or remove project passwords. The lack of password salting enables offline dictionary or brute-force attacks against the password hashes. Successful exploitation could result in unauthorized access to, or modification of, sensitive…
View CSAF Summary Siveillance Video Management Servers contains a vulnerability that could allow a Remote Code Execution attack. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Siveillance Video are affected: Siveillance Video V2023 R3 vers:intdot/<23.3.27 (CVE-2026-3014) Siveillance Video V2024 R1 vers:intdot/<24.1.16 (CVE-2026-3014) Siveillance Video V2025 vers:intdot/<25.1.15 (CVE-2026-3014) CVSS…
View CSAF Summary Successful exploitation of this vulnerability could allow a low-privilege user or attacker to inject a persistent malicious payload via a crafted URL that executes in the context of other users' sessions, including administrators, potentially leading to session hijacking and unauthorized access. The following versions of Johnson Controls Metasys are affected: Metasys 12 vers:all/* (CVE-2026-34491) Metasys 13 vers:all/* (CVE-2026-34491) Metasys 14 Metasys 15 CVSS Vendor…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to decrypt sensitive data, bypass authentication controls, gaining unauthorized access to read arbitrary files on the system, or gain unauthorized access to protected system resources. The following versions of Johnson Controls Inc. Airwall are affected: Airwall <=4.0.4 (CVE-2026-64887, CVE-2026-34492) CVSS Vendor Equipment Vulnerabilities v3 6.8 Johnson Controls Inc. Johnson Controls Inc. Airwall Use of…
View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo DXR and PXC Controllers are affected: Desigo DXR2 vers:intdot/<01.21.233.16-7862 …
View CSAF Summary Parasolid is affected by an out of bounds read vulnerability that could be triggered when the application reads files in X_T format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Parasolid are affected: Parasolid V38.0 vers:intdot/<38.0.235 (CVE-2026-64629) Parasolid V38.1 vers:intdot/<38.1.230 (CVE…
View CSAF Summary Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens recommends to contact customer support for additional information, and follow Fortinet advisory for workarounds and mitigation measures. The following versions of Siemens RUGGEDCOM APE1808 are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-23573, CVE-2026-59839) CVSS Vendor Equipment Vulnerabilities v3 6.1 Siemens Siemens RUGGEDCOM APE1808…
Overview of the attack In July 2026, Kaspersky experts detected a new attack by the Head Mare group. Previously, we classified them as hacktivists, but now we define them as an APT group due to the sophistication of their TTPs and the absence of destructive activity (encryption, wiping) in the targeted infrastructures. In this latest campaign, the attackers exploited a chain of vulnerabilities in the TrueConf video conferencing server and replaced the original TrueConf client installers with…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker with network access to achieve remote code execution. The following versions of Johnson Controls C-CURE 9000 and Victor application server (Update A) are affected: C-CURE 9000 <=v3.10.1 (CVE-2026-21655) victor Application Server <=v4.10 (CVE-2026-21655) victor <=v7.0 (CVE-2026-21655) victor Web victor Web <=v7.1 (CVE-2026-34496) CVSS Vendor Equipment Vulnerabilities v3 9.6 Johnson Controls Johnson…
In this article Pre-encryptionEncryptionPost-encryptionDefending against DeadLock ransomwareIndicators of compromise Microsoft Threat Intelligence tracks DeadLock ransomware as an emerging financially motivated operation distinguished by its use of decentralized infrastructure to support victim communications and data leak operations. Its recovery ecosystem combines the Session messaging network with blockchain-backed services that store and deliver resources used throughout the extortion…
Missing authentication for critical function in Microsoft Azure Kubernetes Service allows an unauthorized attacker to elevate privileges over a network.
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to access sensitive information on the device. The following versions of Johnson Controls Inc. TL280 are affected: TL280 <5.63 (CVE-2026-27871) CVSS Vendor Equipment Vulnerabilities v3 4.1 Johnson Controls Inc. Johnson Controls Inc. TL280 Use of a Broken or Risky Cryptographic Algorithm Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and…
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to bypass security, crash systems, execute unauthorized actions, or compromise data. The following versions of ABB Ability Zenon are affected: IIoT services with MongoDB (4.2) installed on ABB Ability Zenon vers:all/* CVSS Vendor Equipment Vulnerabilities v3 7.8 ABB ABB Ability Zenon Improper Handling of Length Parameter Inconsistency, Improper Neutralization of Null Byte or NUL Character, Collapse of Data…
In this article Attack chain overviewMitigation and protection guidanceIndicators of compromise (IOC)Microsoft Defender XDR detectionsAdvanced hunting queriesLearn more Microsoft Threat Intelligence identified a large-scale npm supply chain attack affecting more than 400 packages across multiple unrelated publishers, including packages associated with major enterprise software ecosystems such as keyv, flat-cache, cache-manager, and others. The malicious releases contain a Mini Shai-Hulud…
Společnost Siemens vydala bezpečnostní aktualizace pro systém Desigo CC. Opravy řeší kritickou zranitelnost (CVSS 9.8), jejíž zneužití může umožnit vzdálené spuštění kódu nebo způsobit nedostupnost systému. Zranitelnost se týká organizací využívajících systém Siemens Desigo CC pro řízení budov (Building Management System - BMS). Provozovatelům se doporučuje co nejdříve nainstalovat dostupné bezpečnostní aktualizace a zajistit, aby systémy nebyly přímo dostupné z internetu, ale byly chráněny…
This vulnerability allows local attackers to escalate privileges on affected installations of Phoenix Contact CHARX SEC-3150 devices. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2026-44106.
This vulnerability allows network-adjacent attackers to create a denial-of-service condition on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 6.5. The following CVEs are assigned: CVE-2026-44090.
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.5. The following CVEs are assigned: CVE-2026-44099.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of AzeoTech DAQFactory. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2026-12390.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of AzeoTech DAQFactory. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2026-12921.
TrendAI™ Research breaks down what changed in CISA’s updated advisory on an ongoing PLC exploitation, why this activity might be more dangerous than a similar campaign in 2023, and how organizations can take action now to protect themselves.
The observed attack chain begins with reconnaissance against the FlexPLM WSDL endpoint, followed by exploitation of the information disclosure vulnerability and CVE-2026-12569, a deserialization flaw that enables unauthenticated remote code execution. Attackers deploy hex-name...
For the latest discoveries in cyber research for the week of 20th July, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES Ernst & Young, a global accounting and professional services company, has disclosed a data breach involving a compromised third-party IT support platform. The exposed support tickets may have contained client documents, tax information, employee details, and other sensitive information submitted while requesting technical assistance. Jscrambler, a…
A technical analysis of three chained zero-day vulnerabilities in Siemens ROX II OT switches that allow privilege escalation and persistent root access. The post Three Steps to the Terminal: A Siemens ROX II Zero-Day Trilogy appeared first on Unit 42.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Rockwell Automation Arena Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2026-6071.
This vulnerability allows local attackers to escalate privileges on affected installations of Fuji Electric Tellus. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2026-8108.
For the latest discoveries in cyber research for the week of 6th July, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES River Bank & Trust, a US financial institution, has experienced a ransomware incident after an unauthorized actor accessed the network of parent company River Financial Corporation on June 16. The bank found ransomware on portions of its server environment and is assessing whether personal data was accessed or exfiltrated. Indra Group, a Spanish…
Written by: Jamie Collier, Robin Grunewald Germany has reclaimed its position as a primary focus for cyber extortion in Europe. While data leak site (DLS) posts rose almost 50% globally in 2025, Google Threat Intelligence (GTI) data shows that the surge is hitting German infrastructure harder and faster than its regional neighbors, marking a significant return to the high-pressure levels previously observed in the country during 2022 and 2023. Cyber Criminals Pivoting Back to Germany Germany…
Explore the latest manufacturing cybersecurity trends, from ransomware to OT takeovers, and real-world risks to production. Learn how to secure your plant.