View CSAF Summary Successful exploitation of this vulnerability could result in memory corruption, a device crash, or a potential remote attack vector without the originating device receiving a CIP error indicating that the request could not be processed. The following versions of Pyramid Solutions NetStaX EtherNet/IP Stack are affected: EtherNet/IP Adapter DLL Kit (EIPA) EtherNet/IP Adapter DLL Kit with CIP Security (EIPA-SECURE) EtherNet/IP Adapter Development Kit (EADK) EtherNet/IP Adapter…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to perform remote code execution on the computer running the client with elevated privileges. The following versions of IXON VPN Client are affected: VPN Client <1.4.7 (CVE-2026-75925) CVSS Vendor Equipment Vulnerabilities v3 9.6 IXON IXON VPN Client Improper Neutralization of CRLF Sequences ('CRLF Injection') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy,…
View CSAF Summary Successful exploitation of this vulnerability could give an attacker the ability to run any commands or code of the attacker's choice on a target machine at the logged-in user's permission level. The following versions of Rockwell Automation ControlFLASH are affected: ControlFLASH <=V15.07 (CVE-2026-12663) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation ControlFLASH Missing Authentication for Critical Function Background Critical…
View CSAF Summary Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to take control of a high-privilege terminal during installation and run arbitrary commands. The following versions of OPCFoundation OPC UA LocalDiscoveryServer (LDS) are affected: UA-LDS-Installers <1.04.420 (CVE-2026-77477) CVSS Vendor Equipment Vulnerabilities v3 4.6 OPCFoundation OPCFoundation OPC UA LocalDiscoveryServer (LDS) Execution with Unnecessary Privileges Background Critical Infrastructure…
View CSAF Summary Successful exploitation of this vulnerability could allow any authenticated user to create projects. The following versions of Inductive Automation Ignition are affected: Ignition <=8.1.53 (CVE-2026-77393) CVSS Vendor Equipment Vulnerabilities v3 8.8 Inductive Automation Inductive Automation Ignition Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company…
View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker accessing sensitive credentials, disrupting connected infrastructure, or manipulating physical equipment, which could present a physical safety risk. The following versions of Tycon Systems TPDIN-Monitor-WEB2 (Update A) are affected: TPDIN-Monitor-WEB2 <2.4.5 (CVE-2026-61884, CVE-2026-55985) CVSS Vendor Equipment Vulnerabilities v3 9.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB2 Missing…
View CSAF Summary Successful exploitation of this vulnerability could crash the module. The device requires a restart to recover. The following versions of Rockwell Automation 1756-ENBT Module are affected: 1756-ENBT module vers:all/* (CVE-2025-10478) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1756-ENBT Module Improper Check for Unusual or Exceptional Conditions Background Critical Infrastructure Sectors: Critical Manufacturing, Food and Agriculture,…
Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.8, CVEs: CVE-2026-20212, Summary: A vulnerability in the Silicon One integration for Cisco Nexus 9000 Series Switches could allow an unauthenticated, remote attacker to execute code with root privileges. This vulnerability exists because TCP ports 43210 and 43211 are accessible in the default Layer 3 (L3) virtual routing and forwarding (VRF). A successful exploit could allow the attacker to connect to…
Serial Number: AV26-871Date: September 2, 2026 As of September 1, 2026, Schneider Electric is affected by vulnerabilities in the following products: NetBotz 5 - 750/755 Versions prior to or equal to 5.5.2 PowerChute Serial Shutdown Versions prior to or equal to 1.5 The Cyber Centre encourages users and administrators to review the provided web links, perform the suggested mitigations and apply the necessary updates. Multiple Vulnerabilities on NetBotz 5 - 750/755 Products Improper Restriction…
Developed by CISA, the Federal Bureau of Investigation, and international partners, this guidance describes how organizations can plan and execute clear, timely, accurate, and audience-appropriate communications during IT and operational technology (OT) outages. Whether caused by cyber threat actors, human error, equipment failure, or natural hazards, service outages can create disruption and societal panic even without speculation from end users and the public as added factors. Outages at one…
Serial number: AV26-869Date: September 1, 2026 As of September 1, 2026, Rockwell Automation is affected by vulnerabilities in the following products: 1756-ENBT Module All versions ArmorStart LT Prior to or equal to v2.001 CompactLogix 5380 / ControlLogix 5580 Prior to or equal to V33 V34.011 to V34.014 V35.011 to V35.013 V36.011 to V36.012 RSLinx Classic Prior to or equal to V4.50 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary…
View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to escalate and execute processes with administrator privileges. The following versions of Rockwell Automation Redundancy Module Configuration Tool are affected: Redundancy Module Configuration Tool 10.00.00 (CVE-2026-9633) Redundancy Module Configuration Tool >=9.00.00|<=10.00.00 (CVE-2026-9634) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation Redundancy Module…
View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed; an out-of-bounds write condition may allow remote code execution. The following versions of Rockwell Automation Historian ME are affected: Series B 5.202 (CVE-2025-12768, CVE-2026-12661) Series C 7.101 (CVE-2025-12768, CVE-2026-12661) CVSS Vendor Equipment Vulnerabilities v3 8 Rockwell Automation Rockwell Automation Historian ME Out-of-bounds Write, Stack-based Buffer Overflow Background…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition on the affected product. The following versions of Rockwell Automation RSLinx Classic are affected: RSLinx Classic <=4.50 (CVE-2026-9621, CVE-2026-9622, CVE-2026-9624, CVE-2026-9625) CVSS Vendor Equipment Vulnerabilities v3 8.6 Rockwell Automation Rockwell Automation RSLinx Classic Integer Overflow or Wraparound, Integer Underflow (Wrap or Wraparound), Buffer Copy…
Serial Number: AV26-864Date: August 31, 2026 As of August 27, 2026, Siemens is affected by a vulnerability in the following products: Element maps-ng V47 Prior to V47.12.3 Element maps-ng V48 Prior to V48.11.3 Element maps-ng V49 Prior to V49.16.1 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. SSA-682041 CERT Services | Siemens
For the latest discoveries in cyber research for the week of 31st August, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES Manchester Airports Group, the UK operator of Manchester, London Stansted, and East Midlands airports, has disclosed a cyberattack that exposed data belonging to about 8.7 million customers. The compromised information includes contact details, vehicle registration numbers, and information collected through car park, lounge, fast-track, and Wi-Fi…
Serial Number: AV26-856Date: August 28, 2026 As of August 25, 2026, National Instruments is affected by vulnerabilities in the following product: LabVIEW Prior to 23.0.0 Prior to 23.3.10 Prior to 24.3.7 Prior to 25.3.5 Prior to 26.3.1 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. Memory Corruption Vulnerabilities in NI LabVIEW - NI Integer Conversion Vulnerability Resulting in an Out of Bounds Read…