Výsledky hledání

sektor: zdravotnictví× typ: zranitelnost× v celém archivu zrušit filtry

29 karet z 30 položek CZ · EN/orig

Rilevate vulnerabilità in Magistra

Nell’ambito del processo di divulgazione coordinata delle vulnerabilità (Coordinated Vulnerability Disclosure – CVD), si rendono note le vulnerabilità individuate da ricercatori di sicurezza, e coordinate da questo CSIRT in collaborazione con il vendor interessato, relative al prodotto di Galeno Sistemi Magistra, software per la gestione del laboratorio galenico di farmacia.

CVE-2026-112168 CVE-2026-112169 CVE-2026-112170 CVE-2026-112171 Galeno Sistemi zdravotnictví IT

tg: zranitelnost

· CSIRT Itálie (ACN) · Rilevate vulnerabilità in Magistra

Múltiples vulnerabilidades en NoviGest Desktop App de Tactis

Multiple Vulnerabilities in Tactis' NoviGest Desktop App Wed, 10/28/2026 - 09:47 Aviso Affected Resources NoviGest Desktop App, version 7.4.4-292: Java RMI service and XML file import from the SAFT module. Description INCIBE has coordinated the disclosure of two vulnerabilities—one critical and one high severity—that affect NoviGest Desktop App by Tactis Serviços Informáticos, LDA, a clinical management software application. The vulnerabilities were discovered by Pablo Jordán Lucia and Marina…

EPSS 0.00 CVSS 9.4 CVE-2026-112197 CVE-2026-112198 Tactis zdravotnictví ES

tg: zranitelnost

· INCIBE-CERT · Múltiples vulnerabilidades en NoviGest Desktop App de Tactis

· zachyceno

Siemens SIMATIC S7-1500 TM MFP

View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1.1. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 TM MFP are affected: SIMATIC S7-1500 TM MFP - GNU/Linux subsystem vers:all/* CVSS Vendor Equipment v3 10 Siemens SIMATIC S7-1500 TM MFP - GNU/Linux subsystem 377 Vulnerabilities Access of…

Siemens výroba a průmysl doprava energetika zdravotnictví US

tg: zranitelnost tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens SIMATIC S7-1500 TM MFP

· zachyceno

Siemens SENTRON 3NA COM Fuse

View CSAF Summary SENTRON 3NA COM Fuse contains a Denial-of-Service vulnerability. Improper handling of a network management message could allow an attacker to trigger a denial-of-service (DoS) condition. Successful exploitation may require the affected network to be re-established to restore normal operation. The following versions of Siemens SENTRON 3NA COM Fuse are affected: SENTRON 3NA COM Fuse vers:intdot/<5.2 (CVE-2024-7322) CVSS Vendor Equipment v3 5.8 Siemens SENTRON 3NA COM Fuse 1…

EPSS 0.00 CVE-2024-7322 Siemens výroba a průmysl doprava energetika zdravotnictví US

tg: zranitelnost tp: DDoS tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens SENTRON 3NA COM Fuse

· zachyceno

SPOJENO PŘES CVE Siemens Industrial Edge Devices

View CSAF Summary Siemens Industrial Edge Devices contain multiple path traversal vulnerabilities that could facilitate an authenticated remote attacker to access sensitive internal information. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens Industrial Edge Devices are…

EPSS 0.00 CVE-2026-44414 CVE-2026-44415 Siemens výroba a průmysl doprava energetika zdravotnictví US

tg: zranitelnost tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens Industrial Edge Devices

· zachyceno

Siemens SIMATIC IPCs

View CSAF Summary The products listed below contain a vulnerability that could allow an attacker to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SIMATIC IPCs are affected: SIMATIC IPC BX-21A vers:intdot/<31.01.13 (CVE-2026-72895) SIMATIC IPC RW-543A vers…

EPSS 0.00 CVE-2026-72895 Siemens výroba a průmysl doprava energetika zdravotnictví US

tg: zranitelnost tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens SIMATIC IPCs

· zachyceno

Siemens RUGGEDCOM CROSSBOW Station Access Controller

View CSAF Summary RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code, cause a denial of service, or obtain sensitive information. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Station Access Controller are affected: RUGGEDCOM…

EPSS 0.73 CVE-2025-6965 CVE-2025-70873 CVE-2025-71316 CVE-2026-11822 CVE-2026-11824 Siemens výroba a průmysl doprava energetika zdravotnictví US

tg: zranitelnost tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens RUGGEDCOM CROSSBOW Station Access Controller

· zachyceno

SPOJENO PŘES CVE Siemens Software Center

View CSAF Summary The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application. Siemens has released a new version for Siemens Software Center and recommends to update to the latest version. Please refer to our blog post for additional information about…

KEV ✓ EPSS 0.01 CVSS 8.4 CVE-2026-110936 Siemens výroba a průmysl doprava energetika zdravotnictví US FI CA IT

tg: zneužíváno tg: zranitelnost tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens Software Center · zachyceno · NCSC-FI · DLL Sideloading Vulnerability in Siemens Software Center · zachyceno · CISA KEV · Siemens Software Center Uncontrolled Search Path Element Vulnerability (CVE-2026-110936) · Cyber Centre Kanada · Siemens security advisory (AV26-1063) · CSIRT Itálie (ACN) · Aggiornamenti per prodotti Siemens

· zachyceno

Siemens PSS(R)SINCAL

View CSAF Summary PSS(R)SINCAL uses WibuKey third-party product that contains an out-of-bounds write vulnerability. An attacker could exploit this vulnerability to cause a system crash, resulting in a denial-of-service condition. This affects PSS SINCAL only when configured to use the legacy WibuKey dongle license type. Siemens is actively preparing updates and recommends applicable mitigations for products where patches are currently unavailable. The following versions of Siemens PSS(R)SINCAL…

EPSS 0.00 CVE-2026-84854 Siemens WIBU Systems energetika doprava výroba a průmysl zdravotnictví US

tg: zranitelnost tp: dodavatelský řetězec tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens PSS(R)SINCAL

· zachyceno

InterSystems Corporation InterSystems IRIS for Health

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to view transmitted data and use that data to log into the device. The following versions of InterSystems Corporation InterSystems IRIS for Health are affected: InterSystems IRIS for Health 2026.2.0.221, 2026.1.0.235, 2025.3.0.226 (CVE-2026-111594, CVE-2026-111594, CVE-2026-111594) CVSS Vendor Equipment v3 8.1 InterSystems Corporation InterSystems IRIS for Health 1 Vulnerability Cleartext Transmission of…

EPSS 0.00 CVE-2026-111594 InterSystems zdravotnictví US

tg: zranitelnost tp: identita

· zachyceno · CISA Advisories · InterSystems Corporation InterSystems IRIS for Health

· zachyceno

Siemens Capital Embedded AR Classic

View CSAF Summary The products listed below contain an out-of-bounds read vulnerability that could allow an attacker to cause abnormal product behavior, instability, or denial of service. Siemens has released a new version for Capital Embedded AR Classic R20-11 and recommends updating to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Capital Embedded…

EPSS 0.00 CVE-2026-89208 Siemens výroba a průmysl doprava energetika zdravotnictví US

tg: zranitelnost tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens Capital Embedded AR Classic

· zachyceno

Siemens WinCC

View CSAF Summary Multiple SIMATIC WinCC versions are affected by a database privilege escalation vulnerability that could allow an authenticated user with access to the database to execute commands on the underlying host system. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends mitigations for products where fixes are not or not yet available. The following versions of Siemens WinCC…

EPSS 0.00 CVE-2026-59241 Siemens výroba a průmysl doprava energetika zdravotnictví US

tg: zranitelnost tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens WinCC

· zachyceno

Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP

View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.7 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP are affected: SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) vers:intdot/>=3.1.7 SIMATIC S7…

Siemens výroba a průmysl doprava energetika zdravotnictví US

tg: zranitelnost tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP

· zachyceno

Siemens Industrial Edge App Publisher

View CSAF Summary The Industrial Edge App Publisher contains a vulnerability chain involving improper certificate validation and the rendering of unescaped data from backend responses. These issues can be combined to allow an attacker on the network to impersonate the management server and execute arbitrary code (RCE) on the local machine through Node.js integration. Siemens has released an update for the Industrial Edge App Publisher and recommends to update to the latest version. The…

EPSS 0.00 CVE-2026-78556 CVE-2026-78557 Siemens výroba a průmysl doprava energetika zdravotnictví US

tg: zranitelnost tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens Industrial Edge App Publisher

· zachyceno

Siemens RUGGEDCOM APE1808 Devices

View CSAF Summary Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens recommends to contact customer support to receive patch and update information. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-33387, CVE-2026-33388, CVE-2026-33389, CVE-2026-33391, CVE-2026-33920) CVSS Vendor Equipment v3 7.5…

EPSS 0.00 CVE-2026-33387 CVE-2026-33388 CVE-2026-33389 CVE-2026-33391 CVE-2026-33920 Siemens Nozomi Networks výroba a průmysl doprava energetika zdravotnictví US

tg: zranitelnost tp: identita tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens RUGGEDCOM APE1808 Devices

· zachyceno

Siemens RUGGEDCOM CROSSBOW

View CSAF Summary RUGGEDCOM CROSSBOW contains multiple vulnerabilities that could allow an attacker to execute arbitrary SQL commands on the underlying database, retrieve sensitive administrative credentials, escalate privileges, and perform unauthorized operations such as modifying system configurations or causing a denial of service. Siemens has released a new version for RUGGEDCOM CROSSBOW and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW…

EPSS 0.00 CVE-2026-89196 CVE-2026-89197 CVE-2026-89198 CVE-2026-89199 CVE-2026-89200 CVE-2026-89201 CVE-2026-89202 CVE-2026-89203 CVE-2026-89204 CVE-2026-89205 CVE-2026-89206 Siemens výroba a průmysl doprava energetika zdravotnictví US

tg: zranitelnost tp: identita tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens RUGGEDCOM CROSSBOW

· zachyceno

Siemens APOGEE, TALON and Desigo PXC/PXM Products

View CSAF Summary The products listed below contain multiple vulnerabilities that could allow an attacker to cause a denial of service and potentially impact the availability of the affected device. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens APOGEE, TALON and Desigo PXC/PXM Products are affected:…

EPSS 0.00 CVE-2026-102073 CVE-2026-102074 CVE-2026-102075 CVE-2026-102076 CVE-2026-89208 Siemens výroba a průmysl doprava energetika zdravotnictví US

tg: zranitelnost tp: DDoS tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens APOGEE, TALON and Desigo PXC/PXM Products

· zachyceno

Siemens SIMATIC S7 Webserver API

View CSAF Summary .NET Client Library for SIMATIC S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory. Siemens has released a new version for .NET Client Library for SIMATIC S7 Webserver API and recommends to update to the latest version. The following versions of Siemens SIMATIC S7 Webserver API are affected: .NET Client Library for SIMATIC S7 Webserver API vers:intdot/…

EPSS 0.00 CVE-2026-85114 CVE-2026-85115 Siemens výroba a průmysl doprava energetika zdravotnictví US

tg: zranitelnost tp: průmyslové systémy

· zachyceno · CISA Advisories · Siemens SIMATIC S7 Webserver API

· zachyceno

HMS Networks PEAK-System PCAN Windows drivers

View CSAF Summary Successful exploitation of these vulnerabilities could crash the Windows kernel. The following versions of HMS Networks PEAK-System PCAN Windows drivers are affected: PEAK-System Device Driver Setup <=5.1.2.1151 (CVE-2026-109576, CVE-2026-101103, CVE-2026-94188, CVE-2026-103672, CVE-2026-110322, CVE-2026-105960) PCAN Windows CAN device drivers <=5.1.2 (CVE-2026-109576, CVE-2026-101103, CVE-2026-94188, CVE-2026-103672, CVE-2026-110322, CVE-2026-105960) CVSS Vendor Equipment v3…

EPSS 0.00 CVE-2026-101103 CVE-2026-103672 CVE-2026-105960 CVE-2026-109576 CVE-2026-110322 CVE-2026-94188 HMS Networks doprava zdravotnictví energetika výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· zachyceno · CISA Advisories · HMS Networks PEAK-System PCAN Windows drivers

· zachyceno

J4Care dcm4che

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to delete stored medical images, disclose patient information, inject forged studies, reassign patient records, overwrite files, and cause a denial-of-service condition. The following versions of J4Care dcm4che are affected: dcm4chee-arc-light 5.35.1 (CVE-2026-97851, CVE-2026-107621, CVE-2026-105273, CVE-2026-101021, CVE-2026-105279, CVE-2026-105667) CVSS Vendor Equipment v3 9.1 J4Care dcm4chee-arc-light…

EPSS 0.00 CVE-2026-101021 CVE-2026-105273 CVE-2026-105279 CVE-2026-105667 CVE-2026-107621 CVE-2026-97851 J4Care zdravotnictví US

tg: zranitelnost tp: soukromí

· zachyceno · CISA Advisories · J4Care dcm4che

· zachyceno

Thermo Fisher Torrent Suite Software

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read arbitrary files on the Torrent Server. The following versions of Thermo Fisher Torrent Suite Software are affected: Torrent Suite Software <=5.18 (CVE-2026-107777) CVSS Vendor Equipment v3 6.5 Thermo Fisher Torrent Suite Software 1 Vulnerability Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Healthcare and Public Health…

EPSS 0.00 CVE-2026-107777 Thermo Fisher zdravotnictví US

tg: zranitelnost tp: průmyslové systémy

· zachyceno · CISA Advisories · Thermo Fisher Torrent Suite Software

SPOJENO PŘES CVE FBI disrupts Chinese hacking tools used to breach critical infrastructure

The FBI has seized seven domains used by Chinese state-sponsored hackers known as Flax Typhoon to operate two hacking tools, MicroScan and FishHub, used in attacks that breached critical infrastructure and other organizations worldwide. [...]

KEV ✓ · ransomware EPSS 1.00 CVE-2014-6278 CVE-2015-3306 CVE-2015-5477 CVE-2016-3081 CVE-2019-11510 CVE-2021-22205 CVE-2021-3199 CVE-2023-22894 Microsoft veřejná správa výroba a průmysl zdravotnictví školství US

tg: varování tg: zneužíváno tg: zranitelnost tg: vymáhání práva tp: malware tp: identita tp: špionáž tp: průmyslové systémy

· BleepingComputer · FBI disrupts Chinese hacking tools used to breach critical infrastructure · zachyceno · CISA Advisories · Chinese Government-linked Cyber Threat Actors Combine Automated and Hands-on Hacking Tools to Steal Sensitive Data

· zachyceno

Digital Watchdog VMAX DVR and NVR Product Lineups

View CSAF Summary Successful exploitation of these vulnerabilities could grant full administrative control of the device, allowing an attacker to view live and recorded surveillance, alter device configurations, and use the device as a network pivot point. The following versions of Digital Watchdog VMAX DVR and NVR Product Lineups are affected: VMAX A1 G4 DVRs vers:all/* (CVE-2026-68953, CVE-2026-66890, CVE-2026-68070, CVE-2026-68950, CVE-2026-66887, CVE-2026-66372) VMAX IP G4 NVRs vers:all/* …

EPSS 0.01 CVSS 9.6 CVE-2026-66372 CVE-2026-66887 CVE-2026-66890 CVE-2026-68070 CVE-2026-68950 CVE-2026-68953 Digital Watchdog veřejná správa zdravotnictví doprava US

tg: zranitelnost tp: identita

· zachyceno · CISA Advisories · Digital Watchdog VMAX DVR and NVR Product Lineups

· zachyceno

NextGen Healthcare Mirth Connect

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to exfiltrate date or cause a denial-of-service condition. The following versions of NextGen Healthcare Mirth Connect are affected: Mirth Connect <=v4.7.1 (CVE-2026-82583, CVE-2026-78224, CVE-2026-82578) CVSS Vendor Equipment Vulnerabilities v3 8.3 NextGen Healthcare NextGen Healthcare Mirth Connect Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Improper Restriction…

EPSS 0.00 CVSS 8.3 CVE-2026-78224 CVE-2026-82578 CVE-2026-82583 NextGen Healthcare zdravotnictví US

tg: zranitelnost

· zachyceno · CISA Advisories · NextGen Healthcare Mirth Connect

· zachyceno

Orthanc DICOM Server

View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated remote attacker to write past the end of a heap allocation when Orthanc decodes an attacker-supplied PNG or JPEG image, resulting in a crash of the Orthanc process and a denial-of-service condition. The following versions of Orthanc DICOM Server are affected: Orthanc DICOM Server <1.13.0. (CVE-2026-87020) CVSS Vendor Equipment Vulnerabilities v3 8.1 Orthanc Orthanc DICOM Server Integer Overflow or…

EPSS 0.01 CVSS 8.1 CVE-2026-87020 Orthanc zdravotnictví US

tg: zranitelnost

· zachyceno · CISA Advisories · Orthanc DICOM Server

· zachyceno

Rockwell Automation Historian ME

View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed; an out-of-bounds write condition may allow remote code execution. The following versions of Rockwell Automation Historian ME are affected: Series B 5.202 (CVE-2025-12768, CVE-2026-12661) Series C 7.101 (CVE-2025-12768, CVE-2026-12661) CVSS Vendor Equipment Vulnerabilities v3 8 Rockwell Automation Rockwell Automation Historian ME Out-of-bounds Write, Stack-based Buffer Overflow Background…

EPSS 0.00 CVSS 8.0 CVE-2025-12768 CVE-2026-12661 Rockwell Automation výroba a průmysl zdravotnictví vodárenství US

tg: zranitelnost tp: průmyslové systémy

· zachyceno · CISA Advisories · Rockwell Automation Historian ME

3rd August – Threat Intelligence Report

For the latest discoveries in cyber research for the week of 27th July, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES Minnesota IT Services has confirmed coordinated cyberattacks affecting more than 30 community water utilities across the state. The incidents briefly disrupted a treatment plant in Braham and affected industrial control systems. Officials reported that drinking water safety was not affected. While the attack was not officially attributed, federal…

KEV ✓ · ransomware EPSS 0.94 CVSS 9.8 CVE-2026-20316 CVE-2026-42897 CVE-2026-59309 CVE-2026-59310 CVE-2026-59726 CVE-2026-63077 CVE-2026-66066 Cisco Broadcom JetBrains Microsoft vodárenství finance zdravotnictví telekomunikace IL

tg: incident tg: zranitelnost tg: přehled tp: phishing tp: únik dat tp: AI tp: průmyslové systémy

· Check Point Research · 3rd August – Threat Intelligence Report