In an industrial network, malicious activity can be hard to tell apart from normal data exchange between devices. Malicious actors routinely rely on legitimate tools and the Living-off-the-Land technique, so a single network connection may show no known signs of an attack: the device uses a familiar protocol and transmits ordinary data. An anomaly can hide in subtle details: the data source, the time of access, or the volume of transferred data may be atypical for a particular device. However,…
Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.8, CVEs: CVE-2026-109618, CVE-2026-109619, Summary: This Security Alert addresses CVE-2026-109618 and CVE-2026-109619. These vulnerabilities, known as PHP2Shell, allow for unauthenticated remote code execution in PHP. Oracle strongly recommends that customers apply the available security patches without delay. The Security Alert advisory will continue to be updated as additional product patches become…
Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.8, CVEs: CVE-2026-114595, CVE-2026-114596, CVE-2026-114597, CVE-2026-114598, Summary: Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition, corrupt memory, disclose sensitive information, or potentially execute arbitrary code. The following versions of EPICS Base are affected: EPICS Base release
View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1.1. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 TM MFP are affected: SIMATIC S7-1500 TM MFP - GNU/Linux subsystem vers:all/* CVSS Vendor Equipment v3 10 Siemens SIMATIC S7-1500 TM MFP - GNU/Linux subsystem 377 Vulnerabilities Access of…
View CSAF Summary SENTRON 3NA COM Fuse contains a Denial-of-Service vulnerability. Improper handling of a network management message could allow an attacker to trigger a denial-of-service (DoS) condition. Successful exploitation may require the affected network to be re-established to restore normal operation. The following versions of Siemens SENTRON 3NA COM Fuse are affected: SENTRON 3NA COM Fuse vers:intdot/<5.2 (CVE-2024-7322) CVSS Vendor Equipment v3 5.8 Siemens SENTRON 3NA COM Fuse 1…
View CSAF Summary Siemens Industrial Edge Devices contain multiple path traversal vulnerabilities that could facilitate an authenticated remote attacker to access sensitive internal information. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens Industrial Edge Devices are…
View CSAF Summary The products listed below contain a vulnerability that could allow an attacker to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SIMATIC IPCs are affected: SIMATIC IPC BX-21A vers:intdot/<31.01.13 (CVE-2026-72895) SIMATIC IPC RW-543A vers…
View CSAF Summary RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code, cause a denial of service, or obtain sensitive information. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Station Access Controller are affected: RUGGEDCOM…
View CSAF Summary The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application. Siemens has released a new version for Siemens Software Center and recommends to update to the latest version. Please refer to our blog post for additional information about…
View CSAF Summary PSS(R)SINCAL uses WibuKey third-party product that contains an out-of-bounds write vulnerability. An attacker could exploit this vulnerability to cause a system crash, resulting in a denial-of-service condition. This affects PSS SINCAL only when configured to use the legacy WibuKey dongle license type. Siemens is actively preparing updates and recommends applicable mitigations for products where patches are currently unavailable. The following versions of Siemens PSS(R)SINCAL…
View CSAF Summary The products listed below contain an out-of-bounds read vulnerability that could allow an attacker to cause abnormal product behavior, instability, or denial of service. Siemens has released a new version for Capital Embedded AR Classic R20-11 and recommends updating to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Capital Embedded…
View CSAF Summary Multiple SIMATIC WinCC versions are affected by a database privilege escalation vulnerability that could allow an authenticated user with access to the database to execute commands on the underlying host system. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends mitigations for products where fixes are not or not yet available. The following versions of Siemens WinCC…
View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.7 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP are affected: SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) vers:intdot/>=3.1.7 SIMATIC S7…
View CSAF Summary The Industrial Edge App Publisher contains a vulnerability chain involving improper certificate validation and the rendering of unescaped data from backend responses. These issues can be combined to allow an attacker on the network to impersonate the management server and execute arbitrary code (RCE) on the local machine through Node.js integration. Siemens has released an update for the Industrial Edge App Publisher and recommends to update to the latest version. The…
View CSAF Summary Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens recommends to contact customer support to receive patch and update information. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-33387, CVE-2026-33388, CVE-2026-33389, CVE-2026-33391, CVE-2026-33920) CVSS Vendor Equipment v3 7.5…
View CSAF Summary RUGGEDCOM CROSSBOW contains multiple vulnerabilities that could allow an attacker to execute arbitrary SQL commands on the underlying database, retrieve sensitive administrative credentials, escalate privileges, and perform unauthorized operations such as modifying system configurations or causing a denial of service. Siemens has released a new version for RUGGEDCOM CROSSBOW and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW…
View CSAF Summary The products listed below contain multiple vulnerabilities that could allow an attacker to cause a denial of service and potentially impact the availability of the affected device. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens APOGEE, TALON and Desigo PXC/PXM Products are affected:…
View CSAF Summary .NET Client Library for SIMATIC S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory. Siemens has released a new version for .NET Client Library for SIMATIC S7 Webserver API and recommends to update to the latest version. The following versions of Siemens SIMATIC S7 Webserver API are affected: .NET Client Library for SIMATIC S7 Webserver API vers:intdot/…
View CSAF Summary Two vulnerabilities in the Web-Based Management (WBM) interface of WAGO CC100, PFC100 G2, PFC200 G2, TP600, Edge Controller and WP400 devices allow an authenticated low-privileged user to bypass intended privilege boundaries. The issues affect both the routing configuration functionality and the authorization model for PROFIBUS configuration management. The following versions of WAGO OS Linux are affected: WAGO Firmware (vers:semver/>=1.0.0|<4.10.0) installed on WAGO Hardware…
View CSAF Summary Successful exploitation of these vulnerabilities could crash the Windows kernel. The following versions of HMS Networks PEAK-System PCAN Windows drivers are affected: PEAK-System Device Driver Setup <=5.1.2.1151 (CVE-2026-109576, CVE-2026-101103, CVE-2026-94188, CVE-2026-103672, CVE-2026-110322, CVE-2026-105960) PCAN Windows CAN device drivers <=5.1.2 (CVE-2026-109576, CVE-2026-101103, CVE-2026-94188, CVE-2026-103672, CVE-2026-110322, CVE-2026-105960) CVSS Vendor Equipment v3…
[FSA-202602] Festo AX OS versions 25.0.1.46 and 25.9.2.4, which are based on PLCnext by Phoenix Contact, used by the Festo product CEPE are affected by multiple OpenSSL vulnerabilities. The vulnerabilities are identified as CVE-2025-15467 and CVE-2025-69419. Attacks may be possible when maliciously crafted firmware, key files, PKCS#12 files, CMS/PKCS#7 content, or digitally signed objects are uploaded and processed by the affected system. In the device context, exploitation typically requires a…
[PPSA-2026-005] The 'Pictory' web config tool, prior to 2.17.0, has a Cross-Site Request Forgery (CSRF) vulnerability, which makes it vulnerable to session takeover. The 'revpipyload' package, prior to version 0.11.1, has a vulnerability in the file management functionality of its XML-RPC interface. This allows an attacker to access or delete arbitrary files that the 'revpipyload' process has access to.
[PPSA-2026-004] The 'piControl' kernel module used in the IndustrialPI, prior to version 2.8.0-1, contains multiple vulnerabilities. Successful exploitation of these vulnerabilities can lead to kernel memory corruption and denial of service.
Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.1, CVEs: CVE-2026-62927, CVE-2026-63252, CVE-2026-58080, CVE-2026-63248, CVE-2026-60007, CVE-2026-61387, Summary: Successful exploitation of these vulnerabilities could allow an attacker to delete protected data, recover user credentials and impersonate legitimate users, or cause the server to stop responding to all clients. Incorrect Authorization, Missing Release of Memory after Effective Lifetime,…
Classification: Severe, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 8.8, CVEs: CVE-2026-92817, Summary: Successful exploitation of this vulnerability could allow an authenticated low-level user to escalate their privileges to a higher level.
View CSAF Summary Successful exploitation of these vulnerabilities could allow a malicious user to access the device and gain administrative access. This access would allow the user to view, edit, and upload configuration files. Further, a malicious user can cause the switch to reboot by navigating to a specific URL on the device. This action can be scripted on the malicious user's local machine to cause continuous rebooting of the switch. The following versions of Red Lion Controls N-Tron 700…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain full unauthorized access to the device. The following versions of Johnson Controls EasyIO FG are affected: EasyIO FG firmware <=2.0b52 (CVE-2026-27872, CVE-2026-27873) CVSS Vendor Equipment v3 7.7 Johnson Controls EasyIO FG firmware 2 Vulnerabilities Use of Hard-coded Credentials, Improper Privilege Management Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial…
[VDE-2026-108] The aas-edge-client is a reference implementation of an Asset Administration Shell (AAS) edge application, published by Murrelektronik GmbH on GitHub for the LNI 4.0 testbed demonstrator. Its REST API is bound to all network interfaces on TCP port 18000, requires no authentication and accepts cross-origin requests from any origin. The reference implementation was never intended for productive use and is no longer maintained. Affected are all aas-edge-client versions.
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker tointercept and read sensitive information, including credentials andsession data. The following versions of Johnson Controls EasyIO Neo Series EC and CW Controllers are affected: EasyIO Neo Series EC Controllers V3.3b62 (CVE-2026-64893) EasyIO Neo Series EC Controllers V3.3b63 (CVE-2026-64893) EasyIO Neo Series CW Controllers V3.3b24 (CVE-2026-64893) EasyIO Neo Series CW Controllers V3.3b25 (CVE-2026-64893)…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain access to sensitive information that could be used to conduct further attacks against the system. The following versions of Johnson Controls EasyIO Neo Series EC and CW Controllers are affected: EasyIO Neo Series EC Controllers V3.3b63 (CVE-2026-64892) EasyIO Neo Series EC Controllers V3.3b62 (CVE-2026-64892) EasyIO Neo Series CW Controllers V3.3b25 (CVE-2026-64892) EasyIO Neo Series CW Controllers…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized access to the database, execute arbitrary code on the host with the highest level of privilege, or gain control of the physical access-control system. The following versions of Armatura LLC Armatura One are affected: Armatura One <4.7.2 (CVE-2023-46604, CVE-2026-94591, CVE-2026-94592, CVE-2026-94593, CVE-2026-94594) Armatura One (USA) <4.6.1 (CVE-2023-46604, CVE-2026-94591, CVE-2026…
View CSAF Summary This advisory is revoked. Re-investigation confirmed the reported behavior is expected platform configuration and does not expose the protected attribute. The following versions of Siemens Mendix Runtime are affected: Siemens Mendix Runtime vers:all/* (CVE-2026-7891) CVSS Vendor Equipment Vulnerabilities v3 9.1 Siemens Siemens Mendix Runtime Insecure Inherited Permissions Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain full code execution on the device. The following versions of lwIP TCP/IP Stack MQTT Client Application are affected: MQTT Client Application >=2.0.1|<=2.2.1 (CVE-2026-87121) CVSS Vendor Equipment Vulnerabilities v3 9.8 lwIP lwIP TCP/IP Stack MQTT Client Application Out-of-bounds Write Background Critical Infrastructure Sectors: Chemical, Communications, Critical Manufacturing, Energy, Financial…
View CSAF Summary A vulnerability has been identified in the Open Interface Services (OIS) web module affecting Siveillance Control and Siveillance Control Pro (versions OIS 3.x.y and OIS 4.x.y) . This vulnerability allows an attacker to upload arbitrary files, which can lead to unauthorized root-level access on the OIS server. Siemens has released patches and updates for Siveillance OIS to apply to the products that incorporate the OIS service, and recommends to update to the latest versions.…
View CSAF Summary SIMOVE Fleetmanager and SIPLANT contain a path traversal vulnerability that could allow an attacker to access files outside of intended scope. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SIMOVE Fleetmanager and SIPLANT are affected: SIMOVE Fleetmanager V3.1 vers:intdot/<3.1.13 (CVE-2026-67367) SIMOVE Fleetmanager V3.2 vers:intdot/<3.2.4 (CVE-2026-67367) SIMOVE Fleetmanager V3.3…
View CSAF Summary A Client Code Execution (CCE) vulnerability has been identified in Desigo CC, potentially allowing malicious actors to execute arbitrary code on client devices through specially crafted graphics documents. This vulnerability leverages user-defined graphics containing embedded scripts that are executed on client application instances. Successful exploitation could lead to compromise of the client operating system and potential lateral movement within the organization. The…
View CSAF Summary Multiple Siemens products are vulnerable to the "Copy Fail" vulnerability. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIPLUS and SIMATIC Products are affected: SIMATIC AX Runtime Core Linux Common Debian vers:all/* (CVE-2026-31431) SIMATIC…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to hijack session cookies and issue state-changing requests as an operator which would allow the attacker to control the programmable logic controller and the physical processes it drives. The following versions of OpenPLC Runtime v3 are affected: OpenPLC 3 (CVE-2026-88020) CVSS Vendor Equipment Vulnerabilities v3 6.1 Autonomy Logic OpenPLC Runtime v3 Improper Neutralization of Input During Web Page…
View CSAF Summary Industrial Edge Management contains an authentication bypass vulnerability that could allow an unauthenticated remote attacker to perform full account takeover by resetting user credentials without completing email verification. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Industrial Edge Management are affected: Industrial Edge Management Cloud vers:all/* (CVE-2026-18963)…
[VDE-2026-089] The Lenze VPN client is vulnerable to a Remote Code Execution. The vulnerability would allow an attacker to perform a remote code execution on the computer running the client with elevated privileges.
View CSAF Summary Schneider Electric is aware of vulnerabilities in its PowerChute Serial Shutdown product. The PowerChute Serial Shutdown product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktops, servers and workstations. Failure to apply the remediation provided below may risk improper authentication validation which could result in disruption of operations and access to system data. The following versions of Schneider Electric…
View CSAF Summary Schneider Electric is aware of a vulnerability in its Modicon M340 https://www.se.com/ww/en/product-range/1468-modicon-m340-pac/, BMXNOR0200H https://www.se.com/us/en/product/BMXNOR0200H/communication-module-modicon-m340-iec-608705101-104-dnp3-for-severe-environments/: Modicon M340 X80 Ethernet Communication Modules, BMXNGD0100 https://www.se.com/us/en/product/BMXNGD0100/communication-module-modicon-m580-global-data-service/: M580 Global Data module, BMXNOC0401 https://www.se…
View CSAF Summary Schneider Electric is aware of multiple vulnerabilities in its NetBotz 5 – 750/755 products.The NetBotz 5 – 750/755 products are security and environmental monitors providing temperature, humidity, leak, smoke, vibration, door contact, and video monitoring capabilities. Failure to apply the remediation provided below may risk arbitrary or remote code execution over the local network, which could result in device manipulation and unauthorized data access. The following versions…
View CSAF Summary Successful exploitation of this vulnerability could allow a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in memory, and thereby allows the attacker to view, tamper with, destroy, or delete control programs. The following versions of Mitsubishi Electric GX Works3 and Motion Control Settings are affected: Mitsubishi Electric GX Works3 vers:all/* (CVE-2026-15688)…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker with access to the same network segment to tamper with communication data in the affected product by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly. The following versions of Mitsubishi Electric CC-Link IE TSN…
Classification: Severe, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 8.6, CVEs: CVE-2026-81573, CVE-2026-81574, CVE-2026-81572, CVE-2026-81576, CVE-2026-81575, Summary: The TRUMPF product versions listed below include a Wibu CodeMeter Runtime version that contains several vulnerabilities, e.g. potentially allowing privilege escalation.
View CSAF Summary A reflected cross site scripting vulnerability in the authentication redirect flow (/auth/) of Teamcenter allows an unauthenticated remote attacker to inject JavaScript into an authenticated user's session by crafting a malicious URL. Successful exploitation may enable the attacker to read data or perform actions within the victim's Teamcenter session. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following…
View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the Secure Lock functionality, potentially resulting in a loss of confidentiality. The…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access privileged management functions or send arbitrary SMS messages through the connected GSM modem. The following versions of mySCADA myPRO Manager are affected: mySCADA myPRO Manager <=2.1 (CVE-2026-73807, CVE-2026-82567) CVSS Vendor Equipment Vulnerabilities v3 9.8 mySCADA Technologies mySCADA myPRO Manager Missing Authorization, Missing Authentication for Critical Function Background Critical…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose information, brute-force hashes, or run arbitrary code in a browser session. The following versions of AVEVA Pipeline Integrity Monitor are affected: AVEVA Pipeline Integrity Monitor <=2025_SP1_P1_build_7.1.9580.8513 (CVE-2026-81821, CVE-2026-81822, CVE-2026-81823, CVE-2026-81824) CVSS Vendor Equipment Vulnerabilities v3 8.4 AVEVA AVEVA Pipeline Integrity Monitor Use of Hard-coded…
View CSAF Summary Successful exploitation of this vulnerability could result in memory corruption, a device crash, or a potential remote attack vector without the originating device receiving a CIP error indicating that the request could not be processed. The following versions of Pyramid Solutions NetStaX EtherNet/IP Stack are affected: EtherNet/IP Adapter DLL Kit (EIPA) EtherNet/IP Adapter DLL Kit with CIP Security (EIPA-SECURE) EtherNet/IP Adapter Development Kit (EADK) EtherNet/IP Adapter…
View CSAF Summary Successful exploitation of these vulnerabilities could result in a loss of webserver availability or allow an attacker to inject malicious scripts that will be executed when other users access the affected page. The following versions of Rockwell Automation ArmorStart LT are affected: ArmorStart LT <=v2.001 (CVE-2026-19471, CVE-2026-19472) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation ArmorStart LT Improper Neutralization of Input During…
View CSAF Summary Successful exploitation of this vulnerability could give an attacker the ability to run any commands or code of the attacker's choice on a target machine at the logged-in user's permission level. The following versions of Rockwell Automation ControlFLASH are affected: ControlFLASH <=V15.07 (CVE-2026-12663) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation ControlFLASH Missing Authentication for Critical Function Background Critical…
View CSAF Summary Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra…
View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to perform a man-in-the-middle (MitM) attack, cause a factory reset, wipe credentials, or retrieve sensitive information. The following versions of Tycon Systems TPDIN-Monitor-WEB3 are affected: TPDIN-Monitor-WEB3 <=2.2.9 (CVE-2026-77847, CVE-2026-82712, CVE-2026-82684) CVSS Vendor Equipment Vulnerabilities v3 8.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB3 Use of Hard-coded Credentials, Cross-Site…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to take control of a high-privilege terminal during installation and run arbitrary commands. The following versions of OPCFoundation OPC UA LocalDiscoveryServer (LDS) are affected: UA-LDS-Installers <1.04.420 (CVE-2026-77477) CVSS Vendor Equipment Vulnerabilities v3 4.6 OPCFoundation OPCFoundation OPC UA LocalDiscoveryServer (LDS) Execution with Unnecessary Privileges Background Critical Infrastructure…
View CSAF Summary Successful exploitation of this vulnerability could allow any authenticated user to create projects. The following versions of Inductive Automation Ignition are affected: Ignition <=8.1.53 (CVE-2026-77393) CVSS Vendor Equipment Vulnerabilities v3 8.8 Inductive Automation Inductive Automation Ignition Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company…
View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker accessing sensitive credentials, disrupting connected infrastructure, or manipulating physical equipment, which could present a physical safety risk. The following versions of Tycon Systems TPDIN-Monitor-WEB2 (Update A) are affected: TPDIN-Monitor-WEB2 <2.4.5 (CVE-2026-61884, CVE-2026-55985) CVSS Vendor Equipment Vulnerabilities v3 9.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB2 Missing…