6

SPOJENO PŘES CVE ABB Ability Edgenius

View CSAF Summary ABB is aware of public reports of a vulnerability CVE‑2026‑31431 (Copy Fail) in the product versions listed as affected in the advisory. An update is available that resolves a publicly reported vulnerability. CVE‑2026‑31431 (Copy Fail) is a Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems. Once root access is obtained, the attacker can effectively gain complete…

KEV ✓ EPSS 1.00 CVSS 7.8 CVE-2026-31431 ABB Linux výroba a průmysl energetika vodárenství US EU AT HU

tg: zneužíváno tg: zranitelnost tg: rozbor tp: průmyslové systémy

· CISA Advisories · ABB Ability Edgenius · Fortinet PSIRT · Linux Kernel Vulnerability copy.fail - CVE-2026-31431 · Elastic Security · Copy Fail and DirtyFrag: Linux Page Cache Bugs in the Wild · CERT-EU · 2026-005: High Vulnerability in the Linux Kernel ("Copy Fail") · CERT.at · Copy Fail Update #1: Kritische Linux-Kernel-Schwachstelle ermöglicht lokale Root-Rechte · NKI Maďarsko · Riasztás a Linux rendszereket érintő Copy Fail sérülékenységről

Schneider Electric PowerChute Serial Shutdown

View CSAF Summary Schneider Electric is aware of vulnerabilities in its PowerChute Serial Shutdown product. The PowerChute Serial Shutdown product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktops, servers and workstations. Failure to apply the remediation provided below may risk improper authentication validation which could result in disruption of operations and access to system data. The following versions of Schneider Electric…

EPSS 0.00 CVSS 5.3 CVE-2026-13348 Schneider Electric energetika výroba a průmysl US

tg: zranitelnost tp: identita tp: průmyslové systémy

· CISA Advisories · Schneider Electric PowerChute Serial Shutdown

Schneider Electric Modicon M340 Controller and Communication Modules

View CSAF Summary Schneider Electric is aware of a vulnerability in its Modicon M340 https://www.se.com/ww/en/product-range/1468-modicon-m340-pac/, BMXNOR0200H https://www.se.com/us/en/product/BMXNOR0200H/communication-module-modicon-m340-iec-608705101-104-dnp3-for-severe-environments/: Modicon M340 X80 Ethernet Communication Modules, BMXNGD0100 https://www.se.com/us/en/product/BMXNGD0100/communication-module-modicon-m580-global-data-service/: M580 Global Data module, BMXNOC0401 https://www.se…

EPSS 0.00 CVSS 7.5 CVE-2025-6625 Schneider Electric energetika vodárenství výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Schneider Electric Modicon M340 Controller and Communication Modules

Schneider Electric NetBotz 5 750/755

View CSAF Summary Schneider Electric is aware of multiple vulnerabilities in its NetBotz 5 – 750/755 products.The NetBotz 5 – 750/755 products are security and environmental monitors providing temperature, humidity, leak, smoke, vibration, door contact, and video monitoring capabilities. Failure to apply the remediation provided below may risk arbitrary or remote code execution over the local network, which could result in device manipulation and unauthorized data access. The following versions…

EPSS 0.01 CVSS 6.4 CVE-2026-13336 CVE-2026-13337 Schneider Electric výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Schneider Electric NetBotz 5 750/755

Mitsubishi Electric GX Works3 and Motion Control Settings

View CSAF Summary Successful exploitation of this vulnerability could allow a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in memory, and thereby allows the attacker to view, tamper with, destroy, or delete control programs. The following versions of Mitsubishi Electric GX Works3 and Motion Control Settings are affected: Mitsubishi Electric GX Works3 vers:all/* (CVE-2026-15688)…

EPSS 0.00 CVSS 8.8 CVE-2026-15688 Mitsubishi Electric výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Mitsubishi Electric GX Works3 and Motion Control Settings

Mitsubishi Electric CC-Link IE TSN Communication Protocol (Update A)

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker with access to the same network segment to tamper with communication data in the affected product by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly. The following versions of Mitsubishi Electric CC-Link IE TSN…

EPSS 0.00 CVE-2026-13584 Mitsubishi Electric výroba a průmysl US

tg: zranitelnost tp: DDoS tp: průmyslové systémy

· CISA Advisories · Mitsubishi Electric CC-Link IE TSN Communication Protocol (Update A)

1

SPOJENO PŘES CVE TRUMPF: Multiple products affected by Wibu CodeMeter vulnerabilities

Classification: Severe, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 8.6, CVEs: CVE-2026-81573, CVE-2026-81574, CVE-2026-81572, CVE-2026-81576, CVE-2026-81575, Summary: The TRUMPF product versions listed below include a Wibu CodeMeter Runtime version that contains several vulnerabilities, e.g. potentially allowing privilege escalation.

EPSS 0.00 CVSS 8.6 CVE-2026-81572 CVE-2026-81573 CVE-2026-81574 CVE-2026-81575 CVE-2026-81576 TRUMPF WIBU-SYSTEMS Wibu-Systems výroba a průmysl FI DE

tg: zranitelnost tp: dodavatelský řetězec tp: průmyslové systémy

· NCSC-FI · TRUMPF: Multiple products affected by Wibu CodeMeter vulnerabilities · CERT@VDE · TRUMPF: Multiple products affected by Wibu CodeMeter vulnerabilities

3

Siemens Teamcenter

View CSAF Summary A reflected cross site scripting vulnerability in the authentication redirect flow (/auth/) of Teamcenter allows an unauthenticated remote attacker to inject JavaScript into an authenticated user's session by crafting a malicious URL. Successful exploitation may enable the attacker to read data or perform actions within the victim's Teamcenter session. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following…

EPSS 0.00 CVSS 6.1 CVE-2026-58113 Siemens výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Siemens Teamcenter

Schneider Electric SCADAPack x70 Products

View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the Secure Lock functionality, potentially resulting in a loss of confidentiality. The…

EPSS 0.00 CVSS 6.5 CVE-2026-81861 Schneider Electric výroba a průmysl energetika US

tg: zranitelnost tp: identita tp: průmyslové systémy

· CISA Advisories · Schneider Electric SCADAPack x70 Products

mySCADA myPRO Manager

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access privileged management functions or send arbitrary SMS messages through the connected GSM modem. The following versions of mySCADA myPRO Manager are affected: mySCADA myPRO Manager <=2.1 (CVE-2026-73807, CVE-2026-82567) CVSS Vendor Equipment Vulnerabilities v3 9.8 mySCADA Technologies mySCADA myPRO Manager Missing Authorization, Missing Authentication for Critical Function Background Critical…

EPSS 0.01 CVSS 9.8 CVE-2026-73807 CVE-2026-82567 mySCADA Technologies výroba a průmysl energetika doprava vodárenství US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · mySCADA myPRO Manager

1

AVEVA Pipeline Integrity Monitor

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose information, brute-force hashes, or run arbitrary code in a browser session. The following versions of AVEVA Pipeline Integrity Monitor are affected: AVEVA Pipeline Integrity Monitor <=2025_SP1_P1_build_7.1.9580.8513 (CVE-2026-81821, CVE-2026-81822, CVE-2026-81823, CVE-2026-81824) CVSS Vendor Equipment Vulnerabilities v3 8.4 AVEVA AVEVA Pipeline Integrity Monitor Use of Hard-coded…

EPSS 0.00 CVSS 8.4 CVE-2026-81821 CVE-2026-81822 CVE-2026-81823 CVE-2026-81824 AVEVA výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · AVEVA Pipeline Integrity Monitor

10

Pyramid Solutions NetStaX EtherNet/IP Stack

View CSAF Summary Successful exploitation of this vulnerability could result in memory corruption, a device crash, or a potential remote attack vector without the originating device receiving a CIP error indicating that the request could not be processed. The following versions of Pyramid Solutions NetStaX EtherNet/IP Stack are affected: EtherNet/IP Adapter DLL Kit (EIPA) EtherNet/IP Adapter DLL Kit with CIP Security (EIPA-SECURE) EtherNet/IP Adapter Development Kit (EADK) EtherNet/IP Adapter…

EPSS 0.00 CVSS 9.8 CVE-2026-78012 Pyramid Solutions výroba a průmysl energetika vodárenství US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Pyramid Solutions NetStaX EtherNet/IP Stack

IXON VPN Client

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to perform remote code execution on the computer running the client with elevated privileges. The following versions of IXON VPN Client are affected: VPN Client <1.4.7 (CVE-2026-75925) CVSS Vendor Equipment Vulnerabilities v3 9.6 IXON IXON VPN Client Improper Neutralization of CRLF Sequences ('CRLF Injection') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy,…

EPSS 0.01 CVSS 9.6 CVE-2026-75925 IXON energetika výroba a průmysl vodárenství US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · IXON VPN Client

Rockwell Automation ArmorStart LT

View CSAF Summary Successful exploitation of these vulnerabilities could result in a loss of webserver availability or allow an attacker to inject malicious scripts that will be executed when other users access the affected page. The following versions of Rockwell Automation ArmorStart LT are affected: ArmorStart LT <=v2.001 (CVE-2026-19471, CVE-2026-19472) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation ArmorStart LT Improper Neutralization of Input During…

EPSS 0.00 CVSS 7.5 CVE-2026-19471 CVE-2026-19472 Rockwell Automation výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Rockwell Automation ArmorStart LT

Rockwell Automation ControlFLASH

View CSAF Summary Successful exploitation of this vulnerability could give an attacker the ability to run any commands or code of the attacker's choice on a target machine at the logged-in user's permission level. The following versions of Rockwell Automation ControlFLASH are affected: ControlFLASH <=V15.07 (CVE-2026-12663) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation ControlFLASH Missing Authentication for Critical Function Background Critical…

EPSS 0.00 CVSS 7.3 CVE-2026-12663 Rockwell Automation výroba a průmysl energetika vodárenství US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Rockwell Automation ControlFLASH

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

View CSAF Summary Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra…

EPSS 0.00 CVSS 8.3 CVE-2026-4827 Schneider Electric energetika vodárenství výroba a průmysl US

tg: zranitelnost tp: identita tp: průmyslové systémy

· CISA Advisories · Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

Tycon Systems TPDIN-Monitor-WEB3

View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to perform a man-in-the-middle (MitM) attack, cause a factory reset, wipe credentials, or retrieve sensitive information. The following versions of Tycon Systems TPDIN-Monitor-WEB3 are affected: TPDIN-Monitor-WEB3 <=2.2.9 (CVE-2026-77847, CVE-2026-82712, CVE-2026-82684) CVSS Vendor Equipment Vulnerabilities v3 8.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB3 Use of Hard-coded Credentials, Cross-Site…

EPSS 0.00 CVSS 8.8 CVE-2026-77847 CVE-2026-82684 CVE-2026-82712 Tycon Systems výroba a průmysl energetika US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Tycon Systems TPDIN-Monitor-WEB3

OPCFoundation OPC UA LocalDiscoveryServer (LDS)

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to take control of a high-privilege terminal during installation and run arbitrary commands. The following versions of OPCFoundation OPC UA LocalDiscoveryServer (LDS) are affected: UA-LDS-Installers <1.04.420 (CVE-2026-77477) CVSS Vendor Equipment Vulnerabilities v3 4.6 OPCFoundation OPCFoundation OPC UA LocalDiscoveryServer (LDS) Execution with Unnecessary Privileges Background Critical Infrastructure…

CVSS 4.6 CVE-2026-77477 OPC Foundation energetika vodárenství výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · OPCFoundation OPC UA LocalDiscoveryServer (LDS)

Inductive Automation Ignition

View CSAF Summary Successful exploitation of this vulnerability could allow any authenticated user to create projects. The following versions of Inductive Automation Ignition are affected: Ignition <=8.1.53 (CVE-2026-77393) CVSS Vendor Equipment Vulnerabilities v3 8.8 Inductive Automation Inductive Automation Ignition Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company…

EPSS 0.01 CVSS 8.8 CVE-2026-77393 Inductive Automation výroba a průmysl energetika US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Inductive Automation Ignition

Tycon Systems TPDIN-Monitor-WEB2 (Update A)

View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker accessing sensitive credentials, disrupting connected infrastructure, or manipulating physical equipment, which could present a physical safety risk. The following versions of Tycon Systems TPDIN-Monitor-WEB2 (Update A) are affected: TPDIN-Monitor-WEB2 <2.4.5 (CVE-2026-61884, CVE-2026-55985) CVSS Vendor Equipment Vulnerabilities v3 9.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB2 Missing…

EPSS 0.00 CVSS 9.8 CVE-2026-55985 CVE-2026-61884 Tycon Systems výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Tycon Systems TPDIN-Monitor-WEB2 (Update A)

Rockwell Automation 1756-ENBT Module

View CSAF Summary Successful exploitation of this vulnerability could crash the module. The device requires a restart to recover. The following versions of Rockwell Automation 1756-ENBT Module are affected: 1756-ENBT module vers:all/* (CVE-2025-10478) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1756-ENBT Module Improper Check for Unusual or Exceptional Conditions Background Critical Infrastructure Sectors: Critical Manufacturing, Food and Agriculture,…

CVSS 7.5 CVE-2025-10478 Rockwell Automation výroba a průmysl doprava vodárenství US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Rockwell Automation 1756-ENBT Module

6

Rockwell Automation FactoryTalk Activation Manager

View CSAF Summary The following versions of Rockwell Automation FactoryTalk Activation Manager are affected: FactoryTalk Activation Manager V5.02_and_below (CVE-2026-16675) CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation FactoryTalk Activation Manager Improper Restriction of Excessive Authentication Attempts Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States…

EPSS 0.00 CVSS 7.8 CVE-2026-16675 Rockwell Automation výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Rockwell Automation FactoryTalk Activation Manager

Rockwell Automation Redundancy Module Configuration Tool

View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to escalate and execute processes with administrator privileges. The following versions of Rockwell Automation Redundancy Module Configuration Tool are affected: Redundancy Module Configuration Tool 10.00.00 (CVE-2026-9633) Redundancy Module Configuration Tool >=9.00.00|<=10.00.00 (CVE-2026-9634) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation Redundancy Module…

EPSS 0.00 CVSS 7.3 CVE-2026-9633 CVE-2026-9634 Rockwell Automation výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Rockwell Automation Redundancy Module Configuration Tool

Rockwell Automation Logix Platform

View CSAF Summary The following versions of Rockwell Automation Logix Platform are affected: ControlLogix 5580 <=V33, V34.011-V34.014, V35.011-V35.013, V36.011-V36.012 (CVE-2026-9637, CVE-2026-9637, CVE-2026-9637, CVE-2026-9637) CompactLogix 5380 <=V33, V34.011-V34.014, V35.011-V35.013, V36.011-V36.012 (CVE-2026-9637, CVE-2026-9637, CVE-2026-9637, CVE-2026-9637) GuardLogix 5580 <=V33, V34.011-V34.014, V35.011-V35.013, V36.011-V36.012 (CVE-2026-9637, CVE-2026-9637, CVE-2026-9637, CVE-2026-9637)…

EPSS 0.00 CVSS 7.5 CVE-2026-9637 Rockwell Automation výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Rockwell Automation Logix Platform

Rockwell Automation ControlLogix, CompactLogix, CompactLogix 5480, GuardLogix, Compact GuardLogix

View CSAF Summary The following versions of Rockwell Automation ControlLogix, CompactLogix, CompactLogix 5480, GuardLogix, Compact GuardLogix are affected: ControlLogix 5580 <34.015, <35.014, <36.013, <37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260) GuardLogix 5580 <34.015, <35.014, <36.013, <37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260) CompactLogix 5380 <34.015, <35.014, <36.013, <37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE…

EPSS 0.03 CVSS 7.5 CVE-2021-42260 Rockwell Automation výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Rockwell Automation ControlLogix, CompactLogix, CompactLogix 5480, GuardLogix, Compact GuardLogix

Rockwell Automation Historian ME

View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed; an out-of-bounds write condition may allow remote code execution. The following versions of Rockwell Automation Historian ME are affected: Series B 5.202 (CVE-2025-12768, CVE-2026-12661) Series C 7.101 (CVE-2025-12768, CVE-2026-12661) CVSS Vendor Equipment Vulnerabilities v3 8 Rockwell Automation Rockwell Automation Historian ME Out-of-bounds Write, Stack-based Buffer Overflow Background…

EPSS 0.00 CVSS 8.0 CVE-2025-12768 CVE-2026-12661 Rockwell Automation výroba a průmysl zdravotnictví vodárenství US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Rockwell Automation Historian ME

Rockwell Automation RSLinx Classic

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition on the affected product. The following versions of Rockwell Automation RSLinx Classic are affected: RSLinx Classic <=4.50 (CVE-2026-9621, CVE-2026-9622, CVE-2026-9624, CVE-2026-9625) CVSS Vendor Equipment Vulnerabilities v3 8.6 Rockwell Automation Rockwell Automation RSLinx Classic Integer Overflow or Wraparound, Integer Underflow (Wrap or Wraparound), Buffer Copy…

EPSS 0.00 CVSS 8.6 CVE-2026-9621 CVE-2026-9622 CVE-2026-9624 CVE-2026-9625 Rockwell Automation výroba a průmysl US

tg: zranitelnost tp: DDoS tp: průmyslové systémy

· CISA Advisories · Rockwell Automation RSLinx Classic

1

[Control Systems] National Instruments security advisory (AV26-856)

Serial Number: AV26-856Date: August 28, 2026 As of August 25, 2026, National Instruments is affected by vulnerabilities in the following product: LabVIEW Prior to 23.0.0 Prior to 23.3.10 Prior to 24.3.7 Prior to 25.3.5 Prior to 26.3.1 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. Memory Corruption Vulnerabilities in NI LabVIEW - NI Integer Conversion Vulnerability Resulting in an Out of Bounds Read…

National Instruments výroba a průmysl energetika vodárenství telekomunikace CA

tg: zranitelnost tp: průmyslové systémy

· Cyber Centre Kanada · [Control Systems] National Instruments security advisory (AV26-856)

1

Murrelektronik: Vulnerability in 'Copy learned MAC Addresses' function enables MAC Spoofing on Xelity Switches

[VDE-2026-061] An information disclosure vulnerability in the web GUI of Murrelektronik Xelity switches causes MAC addresses from the device's MAC address table to be written into a server-side log that is exposed via the device's web interface to unauthenticated users. The leak is triggered when an authenticated administrator invokes the 'Copy learned MAC Addresses' function, which causes a syslog error that inserts the affected MAC addresses into the log output. Once the error has been…

EPSS 0.00 CVE-2026-8173 Murrelektronik výroba a průmysl DE

tg: zranitelnost tp: průmyslové systémy

· CERT@VDE · Murrelektronik: Vulnerability in 'Copy learned MAC Addresses' function enables MAC Spoofing on Xelity Switches

1

New Report: AI threats are here. Why Q2 2026 signals the end of traditional patch cycles

You can’t patch everything. So what do you fix first? Findings in Q2 2026 have changed traditional answers.The latest Quarterly Threat Landscape Report from Rapid7 Labs shows vulnerability disclosures still surging while attackers use automation and AI-assisted tooling to compress the time between disclosure and exploitation. The gap that patch cycles were built to fill is closing. Speed and volume are overwhelming security teams that have relied on traditional patch cycles and reactive…

CVSS 7.0 Microsoft veřejná správa finance zdravotnictví výroba a průmysl US

tg: rozbor tp: ransomware tp: AI tp: špionáž tp: průmyslové systémy

· Rapid7 · New Report: AI threats are here. Why Q2 2026 signals the end of traditional patch cycles

1

Pilz: Multiple Vulnerabilities affecting industrial PC IndustrialPI

[PPSA-2026-003] The Linux kernel used in the IndustrialPI, 'linux-image-revpi-v8', prior to version 6.12.91-revpi0-rpi-v8 contains multiple vulnerabilities. Successful exploitation of these vulnerabilities can give an attacker full control over the device.

KEV ✓ EPSS 1.00 CVE-2026-31431 CVE-2026-43284 CVE-2026-46300 Pilz výroba a průmysl DE

tg: zranitelnost tp: průmyslové systémy

· CERT@VDE · Pilz: Multiple Vulnerabilities affecting industrial PC IndustrialPI

1

Lenze: Incorrect signature validation in the enable SSH routine

[VDE-2026-077] The affected products belong to the Controller or Servo Drive product family and contain a vulnerability in a security-critical activation mechanism for service access. The signature verification of a file used for SSH activation can be compromised, which could allow unauthorized access to the device.

EPSS 0.00 CVE-2026-14837 Lenze výroba a průmysl DE

tg: zranitelnost tp: průmyslové systémy

· CERT@VDE · Lenze: Incorrect signature validation in the enable SSH routine

1