View CSAF Summary Mendix SAML module contains an authentication bypass vulnerability that could allow an unauthenticated remote attacker to gain unauthorized access by replaying a valid SAML assertion in IdP-initiated authentication flows. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Mendix SAML Module are affected: Mendix SAML (Mendix 10 compatible) vers:intdot/<4.2.4 (CVE-2026-89209) Mendix SAML …
View CSAF Summary Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens recommends to contact customer support to receive patch and update information. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-33387, CVE-2026-33388, CVE-2026-33389, CVE-2026-33391, CVE-2026-33920) CVSS Vendor Equipment v3 7.5…
View CSAF Summary RUGGEDCOM CROSSBOW contains multiple vulnerabilities that could allow an attacker to execute arbitrary SQL commands on the underlying database, retrieve sensitive administrative credentials, escalate privileges, and perform unauthorized operations such as modifying system configurations or causing a denial of service. Siemens has released a new version for RUGGEDCOM CROSSBOW and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW…
Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.1, CVEs: CVE-2026-62927, CVE-2026-63252, CVE-2026-58080, CVE-2026-63248, CVE-2026-60007, CVE-2026-61387, Summary: Successful exploitation of these vulnerabilities could allow an attacker to delete protected data, recover user credentials and impersonate legitimate users, or cause the server to stop responding to all clients. Incorrect Authorization, Missing Release of Memory after Effective Lifetime,…
The FBI has seized seven domains used by Chinese state-sponsored hackers known as Flax Typhoon to operate two hacking tools, MicroScan and FishHub, used in attacks that breached critical infrastructure and other organizations worldwide. [...]
View CSAF Summary Successful exploitation of these vulnerabilities could allow a malicious user to access the device and gain administrative access. This access would allow the user to view, edit, and upload configuration files. Further, a malicious user can cause the switch to reboot by navigating to a specific URL on the device. This action can be scripted on the malicious user's local machine to cause continuous rebooting of the switch. The following versions of Red Lion Controls N-Tron 700…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain full unauthorized access to the device. The following versions of Johnson Controls EasyIO FG are affected: EasyIO FG firmware <=2.0b52 (CVE-2026-27872, CVE-2026-27873) CVSS Vendor Equipment v3 7.7 Johnson Controls EasyIO FG firmware 2 Vulnerabilities Use of Hard-coded Credentials, Improper Privilege Management Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial…
View CSAF Summary Industrial Edge Management contains an authentication bypass vulnerability that could allow an unauthenticated remote attacker to perform full account takeover by resetting user credentials without completing email verification. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Industrial Edge Management are affected: Industrial Edge Management Cloud vers:all/* (CVE-2026-18963)…
Executive summary In April 2026, we at Kaspersky’s Global Emergency Response Team (GERT) responded to a security incident at a manufacturing organization in the Middle East. The threat actor obtained domain admin-equivalent control of the organization’s Active Directory environment and authored a malicious Group Policy Object (GPO) named PAYLOAD, linking it at the domain root. Through that single object, the actor delivered ransom notes, hijacked the desktop wallpaper and lock screen, enforced…
View CSAF Summary Schneider Electric is aware of vulnerabilities in its PowerChute Serial Shutdown product. The PowerChute Serial Shutdown product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktops, servers and workstations. Failure to apply the remediation provided below may risk improper authentication validation which could result in disruption of operations and access to system data. The following versions of Schneider Electric…
View CSAF Summary Mendix SAML module contains a vulnerability that could allow unauthenticated remote attackers to hijack an account in specific SSO configurations. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version. The following versions of Siemens Mendix SAML are affected: Mendix SAML (Mendix 10 compatible) vers:intdot/<4.2.3 (CVE-2026-80465) Mendix SAML (Mendix 11 compatible) vers:intdot/<4.2.3 (CVE-2026-80465) Mendix SAML (Mendix 9.24…
View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the Secure Lock functionality, potentially resulting in a loss of confidentiality. The…
View CSAF Summary Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra…