View CSAF Summary Hitachi Energy is aware of multiple vulnerabilities that affect the TRO600 series product versions listed in this document. These vulnerabilities can be exploited for remote code execution (RCE) to carry out further attacks and disclosure of sensitive information. Please refer to the Recommended Immediate Actions section for information about the mitigation/remediation. The following versions of Hitachi Energy TRO600 series products are affected: TRO600 vers:TRO600/<=9.2.1.6,…
View CSAF Summary Hitachi Energy is aware of OS command injection and Dirty Frag vulnerabilities that affect CoreTec product versions listed in this document. Successful exploitation of these vulnerabilities could result in impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy CoreTec Product are affected: CoreTec5 vers:CoreTec5/<=3.4.0, 5…
View CSAF Summary Hitachi Energy is aware of multiple vulnerabilities that affect MicroSCADA X SYS600 product versions listed in this document. These vulnerabilities can be exploited to carry out various attacks on the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy MicroSCADA X SYS600 Product are affected: MicroSCADA X SYS600 vers:MicroSCADA_X_SYS600/<=10.7, 10.8 (CVE-2026-9852, CVE-2026-9853,…
View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect RTU500 product versions listed in this document. These vulnerabilities if exploited can have impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy RTU500 Product are affected: RTU500 series CMU Firmware vers:RTU500_series_CMU_Firmware/>=13.5.1|<=13.5.4, vers:RTU500…
View CSAF Summary Hitachi Energy is publishing this cybersecurity advisory in response to the security findings reported by Dragos affecting end-of-life RTU500 CMU firmware version 9.x. The reported findings are associated with legacy RTU500 firmware versions that were developed according to the cybersecurity requirements, threat landscape, and industry practices that existed at the time of their release. As cybersecurity threats and security expectations have evolved, these end-of-life…
View CSAF Summary Hitachi Energy is aware of RCE (Remote Code Execution) vulnerability in Apache ActiveMQ component of SOI product versions listed in this document. These vulnerabilities can be exploited to carry out various attacks affecting confidentiality, integrity, and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy SOI are affected: SOI vers:SOI/>=2.0.0|<=2.2.0 (CVE…
View CSAF Summary Hitachi Energy is aware of unauthenticated servlet access vulnerabilities that affect Asset Suite product versions listed in this document. These vulnerabilities can be exploited to potentially cause confidentiality, integrity and availability impact on the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy Asset Suite are affected: Asset Suite vers:Asset_Suite/<=9.9.0 (CVE-2026…
View CSAF Summary Hitachi Energy is aware of open-source software vulnerabilities that affect REB500 product versions listed in this document. These vulnerabilities can be exploited to carry out Denial of Service (DoS) attack on the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy REB500 are affected: REB500 vers:REB500/<=8.3.3.1 (CVE-2024-8176, CVE-2025-59375) CVSS Vendor Equipment v3 6.5…
Serial number: AV26-975Date: September 29, 2026 As of September 29, 2026, Hitachi Energy is affected by vulnerabilities in the following product: RTU500 series CMU firmware Prior to 12.7.8, 13.9.1 or later The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. Vulnerabilities in Hitachi Energy RTU500 End-of-Life versions (PDF) Hitachi Vulnerability Information
View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect the FACTS Control systems with GWS component listed in this document. An attacker exploiting these vulnerabilities can cause impact on confidentiality, integrity and availability of the product. Following FACTS Control systems with GWS component deployed from year 2020 onwards are likely affected by the above vulnerabilities. Product deployments without GWS component are not affected. • SVC Light (STATCOM) • Fixed Series…
View CSAF Summary Hitachi Energy is aware of Dirty Frag vulnerabilities that affect APM Edge product versions listed in this document. Successful exploitation of these vulnerabilities could result in impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy APM Edge Product are affected: APM Edge vers:APM_Edge/<=6.10 (CVE-2026-43284, CVE-2026…