View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1.1. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 TM MFP are affected: SIMATIC S7-1500 TM MFP - GNU/Linux subsystem vers:all/* CVSS Vendor Equipment v3 10 Siemens SIMATIC S7-1500 TM MFP - GNU/Linux subsystem 377 Vulnerabilities Access of…
View CSAF Summary SENTRON 3NA COM Fuse contains a Denial-of-Service vulnerability. Improper handling of a network management message could allow an attacker to trigger a denial-of-service (DoS) condition. Successful exploitation may require the affected network to be re-established to restore normal operation. The following versions of Siemens SENTRON 3NA COM Fuse are affected: SENTRON 3NA COM Fuse vers:intdot/<5.2 (CVE-2024-7322) CVSS Vendor Equipment v3 5.8 Siemens SENTRON 3NA COM Fuse 1…
View CSAF Summary Siemens Industrial Edge Devices contain multiple path traversal vulnerabilities that could facilitate an authenticated remote attacker to access sensitive internal information. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens Industrial Edge Devices are…
View CSAF Summary The products listed below contain a vulnerability that could allow an attacker to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SIMATIC IPCs are affected: SIMATIC IPC BX-21A vers:intdot/<31.01.13 (CVE-2026-72895) SIMATIC IPC RW-543A vers…
View CSAF Summary RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code, cause a denial of service, or obtain sensitive information. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Station Access Controller are affected: RUGGEDCOM…
View CSAF Summary The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application. Siemens has released a new version for Siemens Software Center and recommends to update to the latest version. Please refer to our blog post for additional information about…
View CSAF Summary PSS(R)SINCAL uses WibuKey third-party product that contains an out-of-bounds write vulnerability. An attacker could exploit this vulnerability to cause a system crash, resulting in a denial-of-service condition. This affects PSS SINCAL only when configured to use the legacy WibuKey dongle license type. Siemens is actively preparing updates and recommends applicable mitigations for products where patches are currently unavailable. The following versions of Siemens PSS(R)SINCAL…
View CSAF Summary The products listed below contain an out-of-bounds read vulnerability that could allow an attacker to cause abnormal product behavior, instability, or denial of service. Siemens has released a new version for Capital Embedded AR Classic R20-11 and recommends updating to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Capital Embedded…
View CSAF Summary Multiple SIMATIC WinCC versions are affected by a database privilege escalation vulnerability that could allow an authenticated user with access to the database to execute commands on the underlying host system. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends mitigations for products where fixes are not or not yet available. The following versions of Siemens WinCC…
View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.7 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP are affected: SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) vers:intdot/>=3.1.7 SIMATIC S7…
View CSAF Summary The Industrial Edge App Publisher contains a vulnerability chain involving improper certificate validation and the rendering of unescaped data from backend responses. These issues can be combined to allow an attacker on the network to impersonate the management server and execute arbitrary code (RCE) on the local machine through Node.js integration. Siemens has released an update for the Industrial Edge App Publisher and recommends to update to the latest version. The…
View CSAF Summary Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens recommends to contact customer support to receive patch and update information. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-33387, CVE-2026-33388, CVE-2026-33389, CVE-2026-33391, CVE-2026-33920) CVSS Vendor Equipment v3 7.5…
View CSAF Summary RUGGEDCOM CROSSBOW contains multiple vulnerabilities that could allow an attacker to execute arbitrary SQL commands on the underlying database, retrieve sensitive administrative credentials, escalate privileges, and perform unauthorized operations such as modifying system configurations or causing a denial of service. Siemens has released a new version for RUGGEDCOM CROSSBOW and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW…
View CSAF Summary The products listed below contain multiple vulnerabilities that could allow an attacker to cause a denial of service and potentially impact the availability of the affected device. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens APOGEE, TALON and Desigo PXC/PXM Products are affected:…
View CSAF Summary .NET Client Library for SIMATIC S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory. Siemens has released a new version for .NET Client Library for SIMATIC S7 Webserver API and recommends to update to the latest version. The following versions of Siemens SIMATIC S7 Webserver API are affected: .NET Client Library for SIMATIC S7 Webserver API vers:intdot/…
For the latest discoveries in cyber research for the week of 24th August, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES Latvia’s Road Traffic Safety Directorate (CSDD) has confirmed a breach affecting payment records of more than 1.2 million people – roughly two-thirds of the country’s population – as well as 200,000 organizations. The stolen data included identification numbers, license plates, payment amounts, dates and addresses. Attackers reportedly exploited a…
View CSAF Summary Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released new versions for the affected products and recommends to update to the latest versions. The…
View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo DXR and PXC Controllers are affected: Desigo DXR2 vers:intdot/<01.21.233.16-7862 …