Výsledky hledání

sektor: energetika× v celém archivu zrušit filtry

84 karet z 85 položek · strana 1 z 2 CZ · EN/orig

5

SPOJENO PŘES CVE ABB Ability Edgenius

View CSAF Summary ABB is aware of public reports of a vulnerability CVE‑2026‑31431 (Copy Fail) in the product versions listed as affected in the advisory. An update is available that resolves a publicly reported vulnerability. CVE‑2026‑31431 (Copy Fail) is a Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems. Once root access is obtained, the attacker can effectively gain complete…

KEV ✓ EPSS 1.00 CVSS 7.8 CVE-2026-31431 ABB Linux výroba a průmysl energetika vodárenství US EU AT HU

tg: zneužíváno tg: zranitelnost tg: rozbor tp: průmyslové systémy

· CISA Advisories · ABB Ability Edgenius · Fortinet PSIRT · Linux Kernel Vulnerability copy.fail - CVE-2026-31431 · Elastic Security · Copy Fail and DirtyFrag: Linux Page Cache Bugs in the Wild · CERT-EU · 2026-005: High Vulnerability in the Linux Kernel ("Copy Fail") · CERT.at · Copy Fail Update #1: Kritische Linux-Kernel-Schwachstelle ermöglicht lokale Root-Rechte · NKI Maďarsko · Riasztás a Linux rendszereket érintő Copy Fail sérülékenységről

Schneider Electric PowerChute Serial Shutdown

View CSAF Summary Schneider Electric is aware of vulnerabilities in its PowerChute Serial Shutdown product. The PowerChute Serial Shutdown product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktops, servers and workstations. Failure to apply the remediation provided below may risk improper authentication validation which could result in disruption of operations and access to system data. The following versions of Schneider Electric…

EPSS 0.00 CVSS 5.3 CVE-2026-13348 Schneider Electric energetika výroba a průmysl US

tg: zranitelnost tp: identita tp: průmyslové systémy

· CISA Advisories · Schneider Electric PowerChute Serial Shutdown

Schneider Electric Modicon M340 Controller and Communication Modules

View CSAF Summary Schneider Electric is aware of a vulnerability in its Modicon M340 https://www.se.com/ww/en/product-range/1468-modicon-m340-pac/, BMXNOR0200H https://www.se.com/us/en/product/BMXNOR0200H/communication-module-modicon-m340-iec-608705101-104-dnp3-for-severe-environments/: Modicon M340 X80 Ethernet Communication Modules, BMXNGD0100 https://www.se.com/us/en/product/BMXNGD0100/communication-module-modicon-m580-global-data-service/: M580 Global Data module, BMXNOC0401 https://www.se…

EPSS 0.00 CVSS 7.5 CVE-2025-6625 Schneider Electric energetika vodárenství výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Schneider Electric Modicon M340 Controller and Communication Modules

Hitachi Energy FACTS Control Platform (FCP)

View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect the FACTS Control systems with GWS component listed in this document. An attacker exploiting these vulnerabilities can cause impact on confidentiality, integrity and availability of the product. Following FACTS Control systems with GWS component deployed from year 2020 onwards are likely affected by the above vulnerabilities. Product deployments without GWS component are not affected. • SVC Light (STATCOM) • Fixed Series…

EPSS 0.01 CVSS 9.9 CVE-2024-3980 CVE-2024-3982 CVE-2024-4872 CVE-2024-7940 CVE-2024-7941 Hitachi Energy energetika US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Hitachi Energy FACTS Control Platform (FCP)

5

Siemens Reyrolle 7SR5

View CSAF Summary Siemens Reyrolle 7SR5 Before V2.70 is affected by multiple vulnerabilities. Siemens has released a new version for Reyrolle 7SR5 and recommends to update to the latest version. The following versions of Siemens Reyrolle 7SR5 are affected: Reyrolle 7SR5 vers:intdot/<2.70 (CVE-2024-42384, CVE-2024-42385, CVE-2024-42386, CVE-2024-42391, CVE-2024-42392, CVE-2026-62645, CVE-2026-62646, CVE-2026-62647, CVE-2026-62648, CVE-2026-62649, CVE-2026-62650, CVE-2026-62652, CVE-2026-62653,…

EPSS 0.00 CVSS 9.8 CVE-2024-42384 CVE-2024-42385 CVE-2024-42386 CVE-2024-42391 CVE-2024-42392 CVE-2026-62645 CVE-2026-62646 CVE-2026-62647 CVE-2026-62648 CVE-2026-62649 CVE-2026-62650 CVE-2026-62652 CVE-2026-62653 CVE-2026-62654 Siemens energetika US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Siemens Reyrolle 7SR5

Schneider Electric SCADAPack x70 Products

View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the Secure Lock functionality, potentially resulting in a loss of confidentiality. The…

EPSS 0.00 CVSS 6.5 CVE-2026-81861 Schneider Electric výroba a průmysl energetika US

tg: zranitelnost tp: identita tp: průmyslové systémy

· CISA Advisories · Schneider Electric SCADAPack x70 Products

mySCADA myPRO Manager

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access privileged management functions or send arbitrary SMS messages through the connected GSM modem. The following versions of mySCADA myPRO Manager are affected: mySCADA myPRO Manager <=2.1 (CVE-2026-73807, CVE-2026-82567) CVSS Vendor Equipment Vulnerabilities v3 9.8 mySCADA Technologies mySCADA myPRO Manager Missing Authorization, Missing Authentication for Critical Function Background Critical…

EPSS 0.01 CVSS 9.8 CVE-2026-73807 CVE-2026-82567 mySCADA Technologies výroba a průmysl energetika doprava vodárenství US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · mySCADA myPRO Manager

1

ST Engineering iDirect iQ-Series Terminals (Update A)

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized access to device information or cause a denial-of-service condition. The following versions of ST Engineering iDirect iQ-Series Terminals (Update A) are affected: Evolution iQ‑Series terminals <=4.5.2.1 (CVE-2026-38059, CVE-2026-38057, CVE-2026-38056, CVE-2026-38058) 3315‑Series terminals <=4.5.2.1 (CVE-2026-38059, CVE-2026-38057, CVE-2026-38056, CVE-2026-38058) 9‑Series terminals <=4…

EPSS 0.01 CVSS 8.8 CVE-2026-38056 CVE-2026-38057 CVE-2026-38058 CVE-2026-38059 ST Engineering iDirect telekomunikace obrana energetika veřejná správa US

tg: zranitelnost tp: identita

· CISA Advisories · ST Engineering iDirect iQ-Series Terminals (Update A)

1

7

Pyramid Solutions NetStaX EtherNet/IP Stack

View CSAF Summary Successful exploitation of this vulnerability could result in memory corruption, a device crash, or a potential remote attack vector without the originating device receiving a CIP error indicating that the request could not be processed. The following versions of Pyramid Solutions NetStaX EtherNet/IP Stack are affected: EtherNet/IP Adapter DLL Kit (EIPA) EtherNet/IP Adapter DLL Kit with CIP Security (EIPA-SECURE) EtherNet/IP Adapter Development Kit (EADK) EtherNet/IP Adapter…

EPSS 0.00 CVSS 9.8 CVE-2026-78012 Pyramid Solutions výroba a průmysl energetika vodárenství US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Pyramid Solutions NetStaX EtherNet/IP Stack

IXON VPN Client

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to perform remote code execution on the computer running the client with elevated privileges. The following versions of IXON VPN Client are affected: VPN Client <1.4.7 (CVE-2026-75925) CVSS Vendor Equipment Vulnerabilities v3 9.6 IXON IXON VPN Client Improper Neutralization of CRLF Sequences ('CRLF Injection') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy,…

EPSS 0.01 CVSS 9.6 CVE-2026-75925 IXON energetika výroba a průmysl vodárenství US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · IXON VPN Client

Rockwell Automation ControlFLASH

View CSAF Summary Successful exploitation of this vulnerability could give an attacker the ability to run any commands or code of the attacker's choice on a target machine at the logged-in user's permission level. The following versions of Rockwell Automation ControlFLASH are affected: ControlFLASH <=V15.07 (CVE-2026-12663) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation ControlFLASH Missing Authentication for Critical Function Background Critical…

EPSS 0.00 CVSS 7.3 CVE-2026-12663 Rockwell Automation výroba a průmysl energetika vodárenství US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Rockwell Automation ControlFLASH

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

View CSAF Summary Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra…

EPSS 0.00 CVSS 8.3 CVE-2026-4827 Schneider Electric energetika vodárenství výroba a průmysl US

tg: zranitelnost tp: identita tp: průmyslové systémy

· CISA Advisories · Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

Tycon Systems TPDIN-Monitor-WEB3

View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to perform a man-in-the-middle (MitM) attack, cause a factory reset, wipe credentials, or retrieve sensitive information. The following versions of Tycon Systems TPDIN-Monitor-WEB3 are affected: TPDIN-Monitor-WEB3 <=2.2.9 (CVE-2026-77847, CVE-2026-82712, CVE-2026-82684) CVSS Vendor Equipment Vulnerabilities v3 8.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB3 Use of Hard-coded Credentials, Cross-Site…

EPSS 0.00 CVSS 8.8 CVE-2026-77847 CVE-2026-82684 CVE-2026-82712 Tycon Systems výroba a průmysl energetika US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Tycon Systems TPDIN-Monitor-WEB3

OPCFoundation OPC UA LocalDiscoveryServer (LDS)

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to take control of a high-privilege terminal during installation and run arbitrary commands. The following versions of OPCFoundation OPC UA LocalDiscoveryServer (LDS) are affected: UA-LDS-Installers <1.04.420 (CVE-2026-77477) CVSS Vendor Equipment Vulnerabilities v3 4.6 OPCFoundation OPCFoundation OPC UA LocalDiscoveryServer (LDS) Execution with Unnecessary Privileges Background Critical Infrastructure…

CVSS 4.6 CVE-2026-77477 OPC Foundation energetika vodárenství výroba a průmysl US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · OPCFoundation OPC UA LocalDiscoveryServer (LDS)

Inductive Automation Ignition

View CSAF Summary Successful exploitation of this vulnerability could allow any authenticated user to create projects. The following versions of Inductive Automation Ignition are affected: Ignition <=8.1.53 (CVE-2026-77393) CVSS Vendor Equipment Vulnerabilities v3 8.8 Inductive Automation Inductive Automation Ignition Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company…

EPSS 0.01 CVSS 8.8 CVE-2026-77393 Inductive Automation výroba a průmysl energetika US

tg: zranitelnost tp: průmyslové systémy

· CISA Advisories · Inductive Automation Ignition

1

[Control Systems] National Instruments security advisory (AV26-856)

Serial Number: AV26-856Date: August 28, 2026 As of August 25, 2026, National Instruments is affected by vulnerabilities in the following product: LabVIEW Prior to 23.0.0 Prior to 23.3.10 Prior to 24.3.7 Prior to 25.3.5 Prior to 26.3.1 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. Memory Corruption Vulnerabilities in NI LabVIEW - NI Integer Conversion Vulnerability Resulting in an Out of Bounds Read…

National Instruments výroba a průmysl energetika vodárenství telekomunikace CA

tg: zranitelnost tp: průmyslové systémy

· Cyber Centre Kanada · [Control Systems] National Instruments security advisory (AV26-856)

4

Applied Systems Engineering ASE2000 V2 Communications Test Set

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to read or write arbitrary local files, cause the application to issue outbound network requests, or intercept the connection to impersonate the trusted peer, complete the TLS handshake, and read or modify the protected communications. The following versions of Applied Systems Engineering ASE2000 V2 Communications Test Set are affected: ASE2000 >=2.25|<=2.37 (CVE-2018-1285, CVE-2026-18717) CVSS Vendor…

EPSS 0.17 CVSS 9.8 CVE-2018-1285 CVE-2026-18717 Applied Systems Engineering energetika vodárenství výroba a průmysl US

· CISA Advisories · Applied Systems Engineering ASE2000 V2 Communications Test Set

Threat landscape for industrial automation systems. Q2 2026

All threats In Q2 2026, the percentage of ICS computers on which malicious objects were blocked continued to decrease, falling to 19.15%, its lowest level since 2022. Percentage of ICS computers on which malicious objects were blocked, Q3 2023–Q2 2026 Regionally, the percentages ranged from 8.1% in Northern Europe to 27.9% in Africa. Regions ranked by percentage of attacked ICS computers The figures increased in five regions over the quarter, most notably in East Asia (by 2.0 pp) and Africa (by…

Kaspersky výroba a průmysl energetika RU

· Securelist (Kaspersky) · Threat landscape for industrial automation systems. Q2 2026

Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software

Classification: Severe, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.3, CVEs: CVE-2026-15203, Summary: Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanism

EPSS 0.00 CVSS 9.3 CVE-2026-15203 Danfoss výroba a průmysl energetika FI

· NCSC-FI · Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software

1

PLC na internete: aktuálne riziko aj pre kritickú infraštruktúru

Národné centrum kybernetickej bezpečnosti (NCKB) NBÚ upozorňuje na nebezpečenstvo prevádzkovania programovateľných logických radičov (ďalej ako „PLC“) voľne dostupných z verejného internetu. PLC nie je zariadenie, ktoré má byť priamo dostupné z verejného internetu. Programovateľné logické radiče hrajú kľúčovú úlohu takmer vo všetkých odvetviach priemyslu. Ich vystavenie do verejného internetu môže viesť k ohrozeniu útočníkmi s... The post PLC na internete: aktuálne riziko aj pre kritickú…

energetika vodárenství výroba a průmysl telekomunikace SK

· SK-CERT (NBÚ SR) · PLC na internete: aktuálne riziko aj pre kritickú infraštruktúru

3

Siemens SIMATIC IoT2050 Advanced

View CSAF Summary SIMATIC IoT2050 Advanced devices running Industrial OS with Node-RED installed contain a missing authentication vulnerability in the Node-RED HTTP interface that could allow an unauthenticated remote attacker to create malicious flows and execute arbitrary code on the underlying server with maximum privileges. Siemens has released a new version for SIMATIC IoT2050 Advanced and strongly recommends to update to the latest version. The following versions of Siemens SIMATIC…

EPSS 0.01 CVSS 10.0 CVE-2026-58115 Siemens energetika výroba a průmysl doprava US

· CISA Advisories · Siemens SIMATIC IoT2050 Advanced

Ebyte NE2-D11

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized administrative access, disclose sensitive information, modify device configuration, hijack authenticated sessions, and disrupt device operation. The following versions of Ebyte NE2-D11 are affected: NE2-D11 Firmware FW-9167-0-11 CVSS Vendor Equipment Vulnerabilities v3 9.8 Ebyte Ebyte NE2-D11 Missing Authentication for Critical Function, Cleartext Transmission of Sensitive Information…

EPSS 0.01 CVSS 9.8 CVE-2026-71187 CVE-2026-73125 CVE-2026-73809 CVE-2026-73839 CVE-2026-75814 CVE-2026-76179 CVE-2026-76940 Ebyte výroba a průmysl energetika US

· CISA Advisories · Ebyte NE2-D11

1

24th August – Threat Intelligence Report

For the latest discoveries in cyber research for the week of 24th August, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES Latvia’s Road Traffic Safety Directorate (CSDD) has confirmed a breach affecting payment records of more than 1.2 million people – roughly two-thirds of the country’s population – as well as 200,000 organizations. The stolen data included identification numbers, license plates, payment amounts, dates and addresses. Attackers reportedly exploited a…

KEV ✓ · ransomware EPSS 0.41 CVSS 10.0 CVE-2026-12569 CVE-2026-19478 CVE-2026-19489 CVE-2026-19490 Snowflake Siemens GitLab Cisco zdravotnictví výroba a průmysl energetika vodárenství IL

· Check Point Research · 24th August – Threat Intelligence Report

1

SPOJENO PŘES CVE CISA Releases One Industrial Control Systems Advisory

Classification: Important, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 5.3, CVEs: CVE-2026-27875, Summary: CISA released one Industrial Control Systems (ICS) Advisory. This advisory provides timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-26-232-01 Johnson Controls Simplex Incident Manager

EPSS 0.00 CVSS 5.8 CVE-2026-27875 Johnson Controls výroba a průmysl energetika doprava veřejná správa FI US

· NCSC-FI · CISA Releases One Industrial Control Systems Advisory · CISA Advisories · Johnson Controls Simplex Incident Manager

2

Frequently asked questions about the active threat to Siemens S7 Series PLCs

A joint cybersecurity advisory released by multiple U.S. government agencies warns that threat actors are using AI-generated exploitation scripts to target exposed Siemens S7 Series PLCs across critical infrastructure sectors.Key TakeawaysUnattributed threat actors are exploiting known weaknesses and unnecessary internet exposure to conduct reconnaissance and possible pre-positioning for future disruptive attacks against Siemens S7 Series PLCs.The attackers are leveraging AI to build and refine…

Siemens veřejná správa energetika vodárenství výroba a průmysl US

· Tenable Research · Frequently asked questions about the active threat to Siemens S7 Series PLCs

4

NSA, FBI warns of hackers using AI-generated tools in attacks on critical infrastructure technology

The National Security Agency (NSA), FBI and other federal agencies said the campaign is targeting Siemens S7 Series PLCs and was being fueled by “AI-assisted development” alongside exploitation of known vulnerabilities.

Siemens energetika výroba a průmysl vodárenství US

· The Record · NSA, FBI warns of hackers using AI-generated tools in attacks on critical infrastructure technology

Defending Against an Active Threat to Siemens S7 Series PLCs

Executive summary Note: This advisory relates to an active threat to Siemens S7 Series programmable logic controllers (PLCs). However, ongoing PLC targeting activity is broader than Siemens PLCs. All PLC owners and operators should apply relevant mitigations to reduce the risk to their devices and systems. The Siemens-specific content in this advisory should be understood and applied as one subset of the wider threat landscape. Top Mitigations Inventory all Siemens S7 Series programmable logic…

Siemens výroba a průmysl energetika vodárenství obrana US

· CISA Advisories · Defending Against an Active Threat to Siemens S7 Series PLCs

2

More than 200 victims of Medusa ransomware identified over the last year, CISA says

The Cybersecurity and Infrastructure Security Agency (CISA) and FBI updated an advisory on the group initially released in March 2025 — writing that as of April 2026, Medusa actors have hit more than 500 victims. CISA previously said 300 victims, many of which are in critical infrastructure sectors, were attacked as of 2025.

veřejná správa energetika vodárenství telekomunikace US

· The Record · More than 200 victims of Medusa ransomware identified over the last year, CISA says

Siemens Simcenter Nastran

View CSAF Summary Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released new versions for the affected products and recommends to update to the latest versions. The…

EPSS 0.00 CVSS 7.8 CVE-2026-59086 Siemens výroba a průmysl obrana energetika zdravotnictví US

· CISA Advisories · Siemens Simcenter Nastran

1

17th August – Threat Intelligence Report

For the latest discoveries in cyber research for the week of 17th August, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES Colombia’s Ministry of Justice has experienced a ransomware attack that affected part of its technology infrastructure and disrupted public services related to illicit-drug monitoring and legal processes. Officials confirmed that some files were encrypted but stated that no data theft was detected during the incident. MyDr, Poland’s primary…

KEV ✓ EPSS 0.25 CVSS 9.8 CVE-2026-53413 CVE-2026-65400 CVE-2026-68820 CVE-2026-71362 Microsoft Apple Adobe Zoom veřejná správa zdravotnictví obrana energetika IL

· Check Point Research · 17th August – Threat Intelligence Report

1

The Agentic AI threat cluster: Seven incidents, three actors, and what they mean for your exposure

Tenable’s Research Special Operations (RSO) team has been tracking a cluster of agentic AI threat activity since late July 2026. The Taiwan autonomous AI cyber attack confirmed what the cluster data already showed: near-autonomous offensive AI has crossed from theoretical risk to operational reality.Key TakeawaysTaiwan's Ministry of Digital Affairs confirmed a near-autonomous AI cyber attack in July 2026 in which autonomous agents mapped 21 connected government systems, compromised 85 accounts,…

KEV ✓ · ransomware EPSS 1.00 CVE-2025-3248 GitBook veřejná správa energetika US

tg: incident tg: varování tg: rozbor tp: únik dat tp: AI tp: identita tp: špionáž

· Tenable Research · The Agentic AI threat cluster: Seven incidents, three actors, and what they mean for your exposure

7

SPOJENO PŘES CVE Hitachi Energy APM Edge Product

View CSAF Summary Hitachi Energy is aware of Dirty Frag vulnerabilities that affect APM Edge product versions listed in this document. Successful exploitation of these vulnerabilities could result in impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy APM Edge Product are affected: APM Edge vers:APM_Edge/<=6.10 (CVE-2026-43284, CVE-2026…

EPSS 0.93 CVSS 8.8 CVE-2026-43284 CVE-2026-43500 Hitachi Energy energetika US

· CISA Advisories · Hitachi Energy APM Edge Product · Fortinet PSIRT · Linux Kernel vulnerability Dirty Frag

Haiwell IoT Cloud HMI Gateway

View CSAF Summary Successful exploitation of this vulnerability may allow an attacker to inject and execute arbitrary OS commands with root privileges. The following versions of Haiwell IoT Cloud HMI Gateway are affected: Haiwell IoT Cloud HMI Gateway 3.40.1.12 (CVE-2026-19188) CVSS Vendor Equipment Vulnerabilities v3 10 Haiwell Haiwell IoT Cloud HMI Gateway Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors:…

EPSS 0.02 CVSS 10.0 CVE-2026-19188 Haiwell energetika výroba a průmysl vodárenství US

· CISA Advisories · Haiwell IoT Cloud HMI Gateway

AVEVA Enterprise SCADA

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to tamper with serialized data, potentially resulting in code execution during deserialization. The following versions of AVEVA Enterprise SCADA are affected: Enterprise SCADA 2025 (CVE-2025-7639) Enterprise SCADA >=2024|<=2024_SP1_P01 (CVE-2025-7639) Enterprise SCADA >=2023|<=2023_SP1 (CVE-2025-7639) Enterprise SCADA >=2022|<=2022_SP2_P2 (CVE-2025-7639) Enterprise SCADA <=2021_SP2_P5 (CVE-2025-7639)…

EPSS 0.00 CVSS 7.1 CVE-2025-7639 AVEVA výroba a průmysl energetika US

· CISA Advisories · AVEVA Enterprise SCADA

ANDRITZ HIPASE-250 and 250 SCALA

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to read data from the device or gain access to affected workstations. The following versions of ANDRITZ HIPASE-250 and 250 SCALA are affected: HIPASE-250 <=7.20 (CVE-2026-65309, CVE-2026-65310, CVE-2026-65311, CVE-2026-65313) 250 SCALA <=7.20 (CVE-2026-65309, CVE-2026-65310, CVE-2026-65311, CVE-2026-65313) CVSS Vendor Equipment Vulnerabilities v3 8.1 ANDRITZ ANDRITZ HIPASE-250 and 250 SCALA Storing…

EPSS 0.00 CVSS 8.1 CVE-2026-65309 CVE-2026-65310 CVE-2026-65311 CVE-2026-65313 ANDRITZ energetika US

· CISA Advisories · ANDRITZ HIPASE-250 and 250 SCALA

Johnson Controls Metasys

View CSAF Summary Successful exploitation of this vulnerability could allow a low-privilege user or attacker to inject a persistent malicious payload via a crafted URL that executes in the context of other users' sessions, including administrators, potentially leading to session hijacking and unauthorized access. The following versions of Johnson Controls Metasys are affected: Metasys 12 vers:all/* (CVE-2026-34491) Metasys 13 vers:all/* (CVE-2026-34491) Metasys 14 Metasys 15 CVSS Vendor…

EPSS 0.00 CVSS 8.0 CVE-2026-34491 Johnson Controls energetika výroba a průmysl veřejná správa doprava US

· CISA Advisories · Johnson Controls Metasys

Johnson Controls Inc. Airwall

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to decrypt sensitive data, bypass authentication controls, gaining unauthorized access to read arbitrary files on the system, or gain unauthorized access to protected system resources. The following versions of Johnson Controls Inc. Airwall are affected: Airwall <=4.0.4 (CVE-2026-64887, CVE-2026-34492) CVSS Vendor Equipment Vulnerabilities v3 6.8 Johnson Controls Inc. Johnson Controls Inc. Airwall Use of…

EPSS 0.00 CVSS 6.8 CVE-2026-34492 CVE-2026-64887 Johnson Controls výroba a průmysl veřejná správa energetika doprava US

· CISA Advisories · Johnson Controls Inc. Airwall

Siemens Desigo DXR and PXC Controllers

View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo DXR and PXC Controllers are affected: Desigo DXR2 vers:intdot/<01.21.233.16-7862 …

EPSS 0.00 CVSS 4.3 CVE-2026-59693 Siemens energetika zdravotnictví výroba a průmysl doprava US

· CISA Advisories · Siemens Desigo DXR and PXC Controllers

2

[Control Systems] Phoenix Contact security advisory (AV26-811)

Serial number: AV26-811Date: August 12, 2026 As of August 12, 2026, Phoenix Contact is affected by vulnerabilities in the following products: AXC F 1152 Prior to 2026.0.3 AXC F 1252 Prior to 2026.0.3 AXC F 2000 EA Prior to 2026.0.3 AXC F 2152 Prior to 2026.0.3 AXC F 3152 Prior to 2026.0.3 BPC 9102S Prior to 2026.0.3 BPC 9202S Prior to 2026.0.3 Catan C1 Prior to 2026.0.3 EPC 1502 Prior to 2026.0.3 EPC 1522 Prior to 2026.0.3 RFC 4072R Prior to 2026.0.3 RFC 4072S Prior to 2026.0.3 VL3 UPC 2440…

Phoenix Contact výroba a průmysl energetika vodárenství CA

· Cyber Centre Kanada · [Control Systems] Phoenix Contact security advisory (AV26-811)

Siemens RUGGEDCOM APE1808

View CSAF Summary Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens recommends to contact customer support for additional information, and follow Fortinet advisory for workarounds and mitigation measures. The following versions of Siemens RUGGEDCOM APE1808 are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-23573, CVE-2026-59839) CVSS Vendor Equipment Vulnerabilities v3 6.1 Siemens Siemens RUGGEDCOM APE1808…

EPSS 0.00 CVSS 6.1 CVE-2026-23573 CVE-2026-59839 Siemens Fortinet výroba a průmysl energetika doprava US

· CISA Advisories · Siemens RUGGEDCOM APE1808

2

Aggiornamenti per prodotti Siemens

Siemens ha rilasciato aggiornamenti di sicurezza per sanare molteplici vulnerabilità nei propri prodotti, di cui 1 con gravità “critica” e 13 con gravità “alta”. Tali vulnerabilità, qualora sfruttate, potrebbero consentire ad un utente malintenzionato di eseguire codice arbitrario e di leggere file arbitrari sul filesystem dei sistemi interessati.

EPSS 0.01 CVE-2026-50058 CVE-2026-50059 CVE-2026-50060 CVE-2026-50061 CVE-2026-50062 CVE-2026-50063 CVE-2026-50064 CVE-2026-58115 CVE-2026-59086 CVE-2026-59700 CVE-2026-59701 CVE-2026-64629 CVE-2026-69108 CVE-2026-69109 Siemens výroba a průmysl energetika IT

· CSIRT Itálie (ACN) · Aggiornamenti per prodotti Siemens

Head Mare APT is exploiting vulnerabilities in an unpatched TrueConf server to deliver PhantomCore and PhantomGraph to video conference participants

Overview of the attack In July 2026, Kaspersky experts detected a new attack by the Head Mare group. Previously, we classified them as hacktivists, but now we define them as an APT group due to the sophistication of their TTPs and the absence of destructive activity (encryption, wiping) in the targeted infrastructures. In this latest campaign, the attackers exploited a chain of vulnerabilities in the TrueConf video conferencing server and replaced the original TrueConf client installers with…

TrueConf Kaspersky Microsoft energetika výroba a průmysl doprava telekomunikace RU

· Securelist (Kaspersky) · Head Mare APT is exploiting vulnerabilities in an unpatched TrueConf server to deliver PhantomCore and PhantomGraph to video conference participants

1

#StopRansomware: Gunra Ransomware

Advisory at a Glance Title #StopRansomware: Gunra Ransomware Original Publication August 10, 2026 Executive Summary Gunra is a ransomware-as-a-service (RaaS) used by affiliates to target government, critical infrastructure, and other organizations. The Gunra ransomware variant first appeared in 2025 and expanded to RaaS operations in 2026. The actors leverage a double-extortion model, both encrypting data and threatening to publish exfiltrated data to a dedicated leak site (DLS) if the ransom…

KEV ✓ · ransomware EPSS 0.98 CVE-2024-55591 CVE-2025-24472 veřejná správa zdravotnictví finance energetika US

· CISA Advisories · #StopRansomware: Gunra Ransomware

1

2

Johnson Controls Inc. TL280

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to access sensitive information on the device. The following versions of Johnson Controls Inc. TL280 are affected: TL280 <5.63 (CVE-2026-27871) CVSS Vendor Equipment Vulnerabilities v3 4.1 Johnson Controls Inc. Johnson Controls Inc. TL280 Use of a Broken or Risky Cryptographic Algorithm Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and…

EPSS 0.00 CVSS 4.1 CVE-2026-27871 Johnson Controls energetika výroba a průmysl veřejná správa doprava US

· CISA Advisories · Johnson Controls Inc. TL280

ABB Ability Zenon

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to bypass security, crash systems, execute unauthorized actions, or compromise data. The following versions of ABB Ability Zenon are affected: IIoT services with MongoDB (4.2) installed on ABB Ability Zenon vers:all/* CVSS Vendor Equipment Vulnerabilities v3 7.8 ABB ABB Ability Zenon Improper Handling of Length Parameter Inconsistency, Improper Neutralization of Null Byte or NUL Character, Collapse of Data…

KEV ✓ EPSS 0.83 CVSS 7.8 CVE-2020-7921 CVE-2020-7928 CVE-2025-14847 ABB energetika zdravotnictví vodárenství výroba a průmysl US

· CISA Advisories · ABB Ability Zenon

5

Canada’s Bill C-8 is here: Why the 72-hour reporting rule will redefine critical infrastructure security

Canada’s new Critical Cyber Systems Protection Act (Bill C-8) introduces a strict 72-hour cyber incident reporting mandate. Find out how Tenable is helping critical national infrastructure operators bridge the IT/OT divide to ensure full compliance.Key takeaways:Bill C-8 introduces stringent new cyber incident reporting requirements and heavy financial penalties for critical infrastructure operators. Eliminating network blind spots with a hybrid IT/OT discovery approach, including Safe Active…

Tenable telekomunikace energetika doprava finance US

tg: regulace tg: návod tg: propagace tp: průmyslové systémy

· Tenable Research · Canada’s Bill C-8 is here: Why the 72-hour reporting rule will redefine critical infrastructure security

Kritická zranitelnost v systému Siemens Desigo CC

Společnost Siemens vydala bezpečnostní aktualizace pro systém Desigo CC. Opravy řeší kritickou zranitelnost (CVSS 9.8), jejíž zneužití může umožnit vzdálené spuštění kódu nebo způsobit nedostupnost systému. Zranitelnost se týká organizací využívajících systém Siemens Desigo CC pro řízení budov (Building Management System - BMS). Provozovatelům se doporučuje co nejdříve nainstalovat dostupné bezpečnostní aktualizace a zajistit, aby systémy nebyly přímo dostupné z internetu, ale byly chráněny…

CVSS 9.8 Siemens energetika výroba a průmysl CZ

· CSIRT.CZ (CZ.NIC) · Kritická zranitelnost v systému Siemens Desigo CC

Phoenix Contact: Multiple vulnerabilities in the firmware of CHARX SEC3xxx charging controllers

[VDE-2026-008] Multiple vulnerabilities have been identified in the firmware of CHARX SEC-3xxx EV charging controllers, including the CHARX SEC-3000, SEC-3050, SEC-3100, and SEC-3150 models. The flaws could allow attackers to compromise the devices remotely, resulting in a complete loss of confidentiality, integrity, and availability.

Phoenix Contact energetika doprava DE

tg: zranitelnost tp: průmyslové systémy

· CERT@VDE · Phoenix Contact: Multiple vulnerabilities in the firmware of CHARX SEC3xxx charging controllers

ZDI-26-505: (Pwn2Own) Phoenix Contact CHARX SEC-3150 charx-system-config-manager Service CRLF Injection Firewall Bypass Vulnerability

This vulnerability allows network-adjacent attackers to bypass firewall rules on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 5.0. The following CVEs are assigned: CVE-2026-44092.

EPSS 0.00 CVSS 5.0 CVE-2026-44092 Phoenix Contact energetika US

· Zero Day Initiative · ZDI-26-505: (Pwn2Own) Phoenix Contact CHARX SEC-3150 charx-system-config-manager Service CRLF Injection Firewall Bypass Vulnerability

ZDI-26-506: (Pwn2Own) Phoenix Contact CHARX SEC-3150 Insertion of Sensitive Information into Log File Authentication Bypass Vulnerability

This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Phoenix Contact CHARX SEC-3150 devices. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 5.3. The following CVEs are assigned: CVE-2026-44105.

EPSS 0.00 CVSS 5.3 CVE-2026-44105 Phoenix Contact energetika US

· Zero Day Initiative · ZDI-26-506: (Pwn2Own) Phoenix Contact CHARX SEC-3150 Insertion of Sensitive Information into Log File Authentication Bypass Vulnerability