View CSAF Summary Hitachi Energy is aware of multiple vulnerabilities that affect the TRO600 series product versions listed in this document. These vulnerabilities can be exploited for remote code execution (RCE) to carry out further attacks and disclosure of sensitive information. Please refer to the Recommended Immediate Actions section for information about the mitigation/remediation. The following versions of Hitachi Energy TRO600 series products are affected: TRO600 vers:TRO600/<=9.2.1.6,…
View CSAF Summary Hitachi Energy is aware of OS command injection and Dirty Frag vulnerabilities that affect CoreTec product versions listed in this document. Successful exploitation of these vulnerabilities could result in impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy CoreTec Product are affected: CoreTec5 vers:CoreTec5/<=3.4.0, 5…
View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1.1. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 TM MFP are affected: SIMATIC S7-1500 TM MFP - GNU/Linux subsystem vers:all/* CVSS Vendor Equipment v3 10 Siemens SIMATIC S7-1500 TM MFP - GNU/Linux subsystem 377 Vulnerabilities Access of…
View CSAF Summary SENTRON 3NA COM Fuse contains a Denial-of-Service vulnerability. Improper handling of a network management message could allow an attacker to trigger a denial-of-service (DoS) condition. Successful exploitation may require the affected network to be re-established to restore normal operation. The following versions of Siemens SENTRON 3NA COM Fuse are affected: SENTRON 3NA COM Fuse vers:intdot/<5.2 (CVE-2024-7322) CVSS Vendor Equipment v3 5.8 Siemens SENTRON 3NA COM Fuse 1…
View CSAF Summary Siemens Industrial Edge Devices contain multiple path traversal vulnerabilities that could facilitate an authenticated remote attacker to access sensitive internal information. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens Industrial Edge Devices are…
View CSAF Summary The products listed below contain a vulnerability that could allow an attacker to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SIMATIC IPCs are affected: SIMATIC IPC BX-21A vers:intdot/<31.01.13 (CVE-2026-72895) SIMATIC IPC RW-543A vers…
View CSAF Summary RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code, cause a denial of service, or obtain sensitive information. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Station Access Controller are affected: RUGGEDCOM…
View CSAF Summary The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application. Siemens has released a new version for Siemens Software Center and recommends to update to the latest version. Please refer to our blog post for additional information about…
View CSAF Summary PSS(R)SINCAL uses WibuKey third-party product that contains an out-of-bounds write vulnerability. An attacker could exploit this vulnerability to cause a system crash, resulting in a denial-of-service condition. This affects PSS SINCAL only when configured to use the legacy WibuKey dongle license type. Siemens is actively preparing updates and recommends applicable mitigations for products where patches are currently unavailable. The following versions of Siemens PSS(R)SINCAL…
View CSAF Summary The products listed below contain an out-of-bounds read vulnerability that could allow an attacker to cause abnormal product behavior, instability, or denial of service. Siemens has released a new version for Capital Embedded AR Classic R20-11 and recommends updating to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Capital Embedded…
View CSAF Summary Multiple SIMATIC WinCC versions are affected by a database privilege escalation vulnerability that could allow an authenticated user with access to the database to execute commands on the underlying host system. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends mitigations for products where fixes are not or not yet available. The following versions of Siemens WinCC…
View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.7 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP are affected: SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) vers:intdot/>=3.1.7 SIMATIC S7…
View CSAF Summary The Industrial Edge App Publisher contains a vulnerability chain involving improper certificate validation and the rendering of unescaped data from backend responses. These issues can be combined to allow an attacker on the network to impersonate the management server and execute arbitrary code (RCE) on the local machine through Node.js integration. Siemens has released an update for the Industrial Edge App Publisher and recommends to update to the latest version. The…
View CSAF Summary Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens recommends to contact customer support to receive patch and update information. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-33387, CVE-2026-33388, CVE-2026-33389, CVE-2026-33391, CVE-2026-33920) CVSS Vendor Equipment v3 7.5…
View CSAF Summary RUGGEDCOM CROSSBOW contains multiple vulnerabilities that could allow an attacker to execute arbitrary SQL commands on the underlying database, retrieve sensitive administrative credentials, escalate privileges, and perform unauthorized operations such as modifying system configurations or causing a denial of service. Siemens has released a new version for RUGGEDCOM CROSSBOW and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW…
View CSAF Summary The products listed below contain multiple vulnerabilities that could allow an attacker to cause a denial of service and potentially impact the availability of the affected device. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens APOGEE, TALON and Desigo PXC/PXM Products are affected:…
View CSAF Summary .NET Client Library for SIMATIC S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory. Siemens has released a new version for .NET Client Library for SIMATIC S7 Webserver API and recommends to update to the latest version. The following versions of Siemens SIMATIC S7 Webserver API are affected: .NET Client Library for SIMATIC S7 Webserver API vers:intdot/…
View CSAF Summary Hitachi Energy is aware of multiple vulnerabilities that affect MicroSCADA X SYS600 product versions listed in this document. These vulnerabilities can be exploited to carry out various attacks on the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy MicroSCADA X SYS600 Product are affected: MicroSCADA X SYS600 vers:MicroSCADA_X_SYS600/<=10.7, 10.8 (CVE-2026-9852, CVE-2026-9853,…
View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect RTU500 product versions listed in this document. These vulnerabilities if exploited can have impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy RTU500 Product are affected: RTU500 series CMU Firmware vers:RTU500_series_CMU_Firmware/>=13.5.1|<=13.5.4, vers:RTU500…
View CSAF Summary Two vulnerabilities in the Web-Based Management (WBM) interface of WAGO CC100, PFC100 G2, PFC200 G2, TP600, Edge Controller and WP400 devices allow an authenticated low-privileged user to bypass intended privilege boundaries. The issues affect both the routing configuration functionality and the authorization model for PROFIBUS configuration management. The following versions of WAGO OS Linux are affected: WAGO Firmware (vers:semver/>=1.0.0|<4.10.0) installed on WAGO Hardware…
View CSAF Summary Successful exploitation of these vulnerabilities could crash the Windows kernel. The following versions of HMS Networks PEAK-System PCAN Windows drivers are affected: PEAK-System Device Driver Setup <=5.1.2.1151 (CVE-2026-109576, CVE-2026-101103, CVE-2026-94188, CVE-2026-103672, CVE-2026-110322, CVE-2026-105960) PCAN Windows CAN device drivers <=5.1.2 (CVE-2026-109576, CVE-2026-101103, CVE-2026-94188, CVE-2026-103672, CVE-2026-110322, CVE-2026-105960) CVSS Vendor Equipment v3…
Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.1, CVEs: CVE-2026-62927, CVE-2026-63252, CVE-2026-58080, CVE-2026-63248, CVE-2026-60007, CVE-2026-61387, Summary: Successful exploitation of these vulnerabilities could allow an attacker to delete protected data, recover user credentials and impersonate legitimate users, or cause the server to stop responding to all clients. Incorrect Authorization, Missing Release of Memory after Effective Lifetime,…
Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.8, CVEs: CVE-2026-107617, CVE-2026-97858, CVE-2026-105664, Summary: Successful exploitation of these vulnerabilities could allow an attacker to gain control over affected IP cameras: Use of Hard-coded Credentials, Improperly Controlled Modification of Dynamically-Determined Object Attributes, Observable Response Discrepancy
Classification: Severe, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 8.8, CVEs: CVE-2026-92817, Summary: Successful exploitation of this vulnerability could allow an authenticated low-level user to escalate their privileges to a higher level.
Critical infrastructure faces mounting threats from nation-state groups and AI-driven attacks. In the latest installment of our Cybersecurity Awareness Month blog series, learn how leading cybersecurity agencies, such as CISA, are advising critical infrastructure organizations on ways to protect themselves and the essential services they provide. Key takeaways Critical infrastructure organizations often struggle with asset visibility gaps that create hidden attack vectors. Many older OT systems…
View CSAF Summary Hitachi Energy is publishing this cybersecurity advisory in response to the security findings reported by Dragos affecting end-of-life RTU500 CMU firmware version 9.x. The reported findings are associated with legacy RTU500 firmware versions that were developed according to the cybersecurity requirements, threat landscape, and industry practices that existed at the time of their release. As cybersecurity threats and security expectations have evolved, these end-of-life…
View CSAF Summary Successful exploitation of this vulnerability could crash the device being accessed; a buffer overflow condition may allow remote code execution. The following versions of Savannah lwIP SMTP client are affected: lwIP SMTP client 2.2.1 (CVE-2026-15340) CVSS Vendor Equipment v3 9.8 Savannah lwIP SMTP client 1 Vulnerability Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Background Critical Infrastructure Sectors: Energy, Water and Wastewater Systems…
View CSAF Summary Hitachi Energy is aware of RCE (Remote Code Execution) vulnerability in Apache ActiveMQ component of SOI product versions listed in this document. These vulnerabilities can be exploited to carry out various attacks affecting confidentiality, integrity, and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy SOI are affected: SOI vers:SOI/>=2.0.0|<=2.2.0 (CVE…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain full unauthorized access to the device. The following versions of Johnson Controls EasyIO FG are affected: EasyIO FG firmware <=2.0b52 (CVE-2026-27872, CVE-2026-27873) CVSS Vendor Equipment v3 7.7 Johnson Controls EasyIO FG firmware 2 Vulnerabilities Use of Hard-coded Credentials, Improper Privilege Management Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial…
View CSAF Summary Hitachi Energy is aware of unauthenticated servlet access vulnerabilities that affect Asset Suite product versions listed in this document. These vulnerabilities can be exploited to potentially cause confidentiality, integrity and availability impact on the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy Asset Suite are affected: Asset Suite vers:Asset_Suite/<=9.9.0 (CVE-2026…
View CSAF Summary Hitachi Energy is aware of open-source software vulnerabilities that affect REB500 product versions listed in this document. These vulnerabilities can be exploited to carry out Denial of Service (DoS) attack on the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy REB500 are affected: REB500 vers:REB500/<=8.3.3.1 (CVE-2024-8176, CVE-2025-59375) CVSS Vendor Equipment v3 6.5…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker tointercept and read sensitive information, including credentials andsession data. The following versions of Johnson Controls EasyIO Neo Series EC and CW Controllers are affected: EasyIO Neo Series EC Controllers V3.3b62 (CVE-2026-64893) EasyIO Neo Series EC Controllers V3.3b63 (CVE-2026-64893) EasyIO Neo Series CW Controllers V3.3b24 (CVE-2026-64893) EasyIO Neo Series CW Controllers V3.3b25 (CVE-2026-64893)…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to escalate privileges or overwrite files. The following versions of ABB Protection and Control IED Manager PCM600 are affected: Protection and Control IED Manager PCM600 <=2.14 (CVE-2026-15952, CVE-2026-15953) CVSS Vendor Equipment Vulnerabilities v3 6.4 ABB ABB Protection and Control IED Manager PCM600 Incorrect Permission Assignment for Critical Resource, Improper Limitation of a Pathname to a…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain access to sensitive information that could be used to conduct further attacks against the system. The following versions of Johnson Controls EasyIO Neo Series EC and CW Controllers are affected: EasyIO Neo Series EC Controllers V3.3b63 (CVE-2026-64892) EasyIO Neo Series EC Controllers V3.3b62 (CVE-2026-64892) EasyIO Neo Series CW Controllers V3.3b25 (CVE-2026-64892) EasyIO Neo Series CW Controllers…
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Monta monta.app are affected: monta.app vers:all/* (CVE-2026-95102, CVE-2026-97363, CVE-2026-97212, CVE-2026-93474) CVSS Vendor Equipment Vulnerabilities v3 9.4 Monta Monta monta.app Missing Authentication for Critical Function, Improper…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized access to the database, execute arbitrary code on the host with the highest level of privilege, or gain control of the physical access-control system. The following versions of Armatura LLC Armatura One are affected: Armatura One <4.7.2 (CVE-2023-46604, CVE-2026-94591, CVE-2026-94592, CVE-2026-94593, CVE-2026-94594) Armatura One (USA) <4.6.1 (CVE-2023-46604, CVE-2026-94591, CVE-2026…
Serial number: AV26-975Date: September 29, 2026 As of September 29, 2026, Hitachi Energy is affected by vulnerabilities in the following product: RTU500 series CMU firmware Prior to 12.7.8, 13.9.1 or later The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. Vulnerabilities in Hitachi Energy RTU500 End-of-Life versions (PDF) Hitachi Vulnerability Information
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to replace software and execute arbitrary code with root privileges. The following versions of Lantronix G520 Series Cellular Gateway are affected: G520 Series 2.6.0.4R6_stable (CVE-2026-84409, CVE-2026-91191) CVSS Vendor Equipment Vulnerabilities v3 7.5 Lantronix Lantronix G520 Series Cellular Gateway Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access critical data or execute arbitrary code. The following versions of Toptech TMS7 and TopHAT are affected: TMS7 7.6.3 (CVE-2026-71379, CVE-2026-70356, CVE-2026-72510, CVE-2026-63713, CVE-2026-68954, CVE-2026-68068, CVE-2026-72507, CVE-2026-71302, CVE-2026-69662, CVE-2026-71189) TopHAT 7.6.3 (CVE-2026-71379, CVE-2026-70356, CVE-2026-72510, CVE-2026-63713, CVE-2026-68954, CVE-2026-68068, CVE-2026…
Introduction The Federal Bureau of Investigation (FBI) and Cybersecurity and Infrastructure Security Agency (CISA)—hereafter referred to as the “authoring agencies”—have published this fact sheet to highlight considerations for critical infrastructure entities to reduce risk and minimize vulnerabilities when working with third-party industrial control system (ICS) integrators. ICS is an umbrella term referring to integrated networks of hardware and software designed to monitor and automate…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain full code execution on the device. The following versions of lwIP TCP/IP Stack MQTT Client Application are affected: MQTT Client Application >=2.0.1|<=2.2.1 (CVE-2026-87121) CVSS Vendor Equipment Vulnerabilities v3 9.8 lwIP lwIP TCP/IP Stack MQTT Client Application Out-of-bounds Write Background Critical Infrastructure Sectors: Chemical, Communications, Critical Manufacturing, Energy, Financial…
View CSAF Summary Multiple Siemens products are vulnerable to the "Copy Fail" vulnerability. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIPLUS and SIMATIC Products are affected: SIMATIC AX Runtime Core Linux Common Debian vers:all/* (CVE-2026-31431) SIMATIC…
View CSAF Summary The products listed below contain a denial of service vulnerability that could allow an attacker to force the devices into protection mode under certain conditions. This disables remote connectivity functions (Web Access) to the devices. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens WTV676 and WTV776 are affected: WTV676-HB6035 Web Interface vers:intdot/<3.94 (CVE-2026-89207)…
View CSAF Summary Successful exploitation of this vulnerability could result in a system crash, a DoS, or memory corruption, which could lead to code execution on the victim system. The following versions of lwIP (Lightweight IP) are affected: API >=2.0.1|<=2.2.1 (CVE-2026-91018) CVSS Vendor Equipment Vulnerabilities v3 8.8 lwIP lwIP (Lightweight IP) Double Free Background Critical Infrastructure Sectors: Chemical, Communications, Critical Manufacturing, Energy, Financial Services, Healthcare…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to hijack session cookies and issue state-changing requests as an operator which would allow the attacker to control the programmable logic controller and the physical processes it drives. The following versions of OpenPLC Runtime v3 are affected: OpenPLC 3 (CVE-2026-88020) CVSS Vendor Equipment Vulnerabilities v3 6.1 Autonomy Logic OpenPLC Runtime v3 Improper Neutralization of Input During Web Page…
[VDE-2026-089] The Lenze VPN client is vulnerable to a Remote Code Execution. The vulnerability would allow an attacker to perform a remote code execution on the computer running the client with elevated privileges.
View CSAF Summary Schneider Electric is aware of vulnerabilities in its PowerChute Serial Shutdown product. The PowerChute Serial Shutdown product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktops, servers and workstations. Failure to apply the remediation provided below may risk improper authentication validation which could result in disruption of operations and access to system data. The following versions of Schneider Electric…
View CSAF Summary Schneider Electric is aware of a vulnerability in its Modicon M340 https://www.se.com/ww/en/product-range/1468-modicon-m340-pac/, BMXNOR0200H https://www.se.com/us/en/product/BMXNOR0200H/communication-module-modicon-m340-iec-608705101-104-dnp3-for-severe-environments/: Modicon M340 X80 Ethernet Communication Modules, BMXNGD0100 https://www.se.com/us/en/product/BMXNGD0100/communication-module-modicon-m580-global-data-service/: M580 Global Data module, BMXNOC0401 https://www.se…
View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect the FACTS Control systems with GWS component listed in this document. An attacker exploiting these vulnerabilities can cause impact on confidentiality, integrity and availability of the product. Following FACTS Control systems with GWS component deployed from year 2020 onwards are likely affected by the above vulnerabilities. Product deployments without GWS component are not affected. • SVC Light (STATCOM) • Fixed Series…
View CSAF Summary Siemens Reyrolle 7SR5 Before V2.70 is affected by multiple vulnerabilities. Siemens has released a new version for Reyrolle 7SR5 and recommends to update to the latest version. The following versions of Siemens Reyrolle 7SR5 are affected: Reyrolle 7SR5 vers:intdot/<2.70 (CVE-2024-42384, CVE-2024-42385, CVE-2024-42386, CVE-2024-42391, CVE-2024-42392, CVE-2026-62645, CVE-2026-62646, CVE-2026-62647, CVE-2026-62648, CVE-2026-62649, CVE-2026-62650, CVE-2026-62652, CVE-2026-62653,…
View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the Secure Lock functionality, potentially resulting in a loss of confidentiality. The…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access privileged management functions or send arbitrary SMS messages through the connected GSM modem. The following versions of mySCADA myPRO Manager are affected: mySCADA myPRO Manager <=2.1 (CVE-2026-73807, CVE-2026-82567) CVSS Vendor Equipment Vulnerabilities v3 9.8 mySCADA Technologies mySCADA myPRO Manager Missing Authorization, Missing Authentication for Critical Function Background Critical…
View CSAF Summary Successful exploitation of this vulnerability could result in memory corruption, a device crash, or a potential remote attack vector without the originating device receiving a CIP error indicating that the request could not be processed. The following versions of Pyramid Solutions NetStaX EtherNet/IP Stack are affected: EtherNet/IP Adapter DLL Kit (EIPA) EtherNet/IP Adapter DLL Kit with CIP Security (EIPA-SECURE) EtherNet/IP Adapter Development Kit (EADK) EtherNet/IP Adapter…
View CSAF Summary Successful exploitation of this vulnerability could give an attacker the ability to run any commands or code of the attacker's choice on a target machine at the logged-in user's permission level. The following versions of Rockwell Automation ControlFLASH are affected: ControlFLASH <=V15.07 (CVE-2026-12663) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation ControlFLASH Missing Authentication for Critical Function Background Critical…
View CSAF Summary Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra…
View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to perform a man-in-the-middle (MitM) attack, cause a factory reset, wipe credentials, or retrieve sensitive information. The following versions of Tycon Systems TPDIN-Monitor-WEB3 are affected: TPDIN-Monitor-WEB3 <=2.2.9 (CVE-2026-77847, CVE-2026-82712, CVE-2026-82684) CVSS Vendor Equipment Vulnerabilities v3 8.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB3 Use of Hard-coded Credentials, Cross-Site…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to take control of a high-privilege terminal during installation and run arbitrary commands. The following versions of OPCFoundation OPC UA LocalDiscoveryServer (LDS) are affected: UA-LDS-Installers <1.04.420 (CVE-2026-77477) CVSS Vendor Equipment Vulnerabilities v3 4.6 OPCFoundation OPCFoundation OPC UA LocalDiscoveryServer (LDS) Execution with Unnecessary Privileges Background Critical Infrastructure…
View CSAF Summary Successful exploitation of this vulnerability could allow any authenticated user to create projects. The following versions of Inductive Automation Ignition are affected: Ignition <=8.1.53 (CVE-2026-77393) CVSS Vendor Equipment Vulnerabilities v3 8.8 Inductive Automation Inductive Automation Ignition Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company…