Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.8, CVEs: CVE-2026-109618, CVE-2026-109619, Summary: This Security Alert addresses CVE-2026-109618 and CVE-2026-109619. These vulnerabilities, known as PHP2Shell, allow for unauthenticated remote code execution in PHP. Oracle strongly recommends that customers apply the available security patches without delay. The Security Alert advisory will continue to be updated as additional product patches become…
The NCSC warns that ‘tech on the cheap’ has left UK organisations exposed to AI uncovering and exploiting longstanding cyber security weaknesses and calls for urgent investment in resilience.
NCSC:s incidenthanteringsfunktion CERT-SE har löpande kontakt med berörda aktörer med anledning av de incidenter som drabbat uppkopplade frys- och kylsystem inom dagligvaruhandeln. Organisationer som misstänker eller har drabbats av it-incidenter kan alltid kontakta CERT-SE för stöd och rådgivning.
A cyberattack on refrigeration systems has disrupted stores run by multiple supermarket chains across several European countries after hackers remotely changed temperature settings on freezers and cooling systems. [...]
Supermarket and grocery store refrigerators across Europe appear to have been hacked early Monday — the second such incident in recent weeks where attackers have manipulated temperature controls and caused stock to spoil.
View CSAF Summary Hitachi Energy is aware of multiple vulnerabilities that affect the TRO600 series product versions listed in this document. These vulnerabilities can be exploited for remote code execution (RCE) to carry out further attacks and disclosure of sensitive information. Please refer to the Recommended Immediate Actions section for information about the mitigation/remediation. The following versions of Hitachi Energy TRO600 series products are affected: TRO600 vers:TRO600/<=9.2.1.6,…
View CSAF Summary Hitachi Energy is aware of OS command injection and Dirty Frag vulnerabilities that affect CoreTec product versions listed in this document. Successful exploitation of these vulnerabilities could result in impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy CoreTec Product are affected: CoreTec5 vers:CoreTec5/<=3.4.0, 5…
Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.8, CVEs: CVE-2026-114595, CVE-2026-114596, CVE-2026-114597, CVE-2026-114598, Summary: Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition, corrupt memory, disclose sensitive information, or potentially execute arbitrary code. The following versions of EPICS Base are affected: EPICS Base release
Classification: Important, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 7.7, CVEs: CVE-2026-111459, CVE-2026-111460, CVE-2026-111461, Summary: This security advisory addresses one vulnerability identified in Moxa Remote Connect Suite (MRC Client) and two vulnerabilities identified in the OnCell G3150A-LTE Series. CVE-2026-111459 - Unauthenticated server-supplied OpenVPN configuration in Moxa Remote Connect Suite (MRC Client) An improper certificate validation vulnerability…
Serial Number: AV26-1091 Date: October 27, 2026 As of October 27, 2026, Hitachi is affected by vulnerabilities in the following products: HiRDB Server Version 10 Multiple versions HiRDB Server Version 9 Multiple versions HiRDB Server Version 9(32) Multiple versions HiRDB Server with Additional Function Version 9 Multiple versions HiRDB Server with Additional Function Version 9(32) Multiple versions JP1/Automatic Job Management System 3 - Agent Multiple versions JP1/Automatic Job Management…
Serial number: AV26-1090 Date: October 27, 2026 As of October 26, 2026, Johnson Controls is affected by vulnerabilities in the following product: Kantech Entrapass Prior to 9.20 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. Johnson Controls has confirmed two vulnerabilities impacting Kantech Entrapass (PDF) Johnson Controls Product Security Advisories
AI is widening the attack surface of the critical infrastructure facilities and services that state, local, and education (SLED) organizations run. In the final post of our Cybersecurity Awareness Month series, we explain how a whole-of-state security approach can help SLED agencies protect their critical infrastructure. Key takeaways Because cyber attackers prey on under-resourced targets, they often go after SLED organizations, especially those that operate critical infrastructure, including…
View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1.1. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 TM MFP are affected: SIMATIC S7-1500 TM MFP - GNU/Linux subsystem vers:all/* CVSS Vendor Equipment v3 10 Siemens SIMATIC S7-1500 TM MFP - GNU/Linux subsystem 377 Vulnerabilities Access of…
View CSAF Summary SENTRON 3NA COM Fuse contains a Denial-of-Service vulnerability. Improper handling of a network management message could allow an attacker to trigger a denial-of-service (DoS) condition. Successful exploitation may require the affected network to be re-established to restore normal operation. The following versions of Siemens SENTRON 3NA COM Fuse are affected: SENTRON 3NA COM Fuse vers:intdot/<5.2 (CVE-2024-7322) CVSS Vendor Equipment v3 5.8 Siemens SENTRON 3NA COM Fuse 1…
View CSAF Summary SIMATIC S7-1500 devices contain multiple vulnerabilities in the web server that could allow an attacker to execute malicious code in an authorized user’s browser session and perform PLC operations within the scope of that user’s authorization. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7 PLCs Web Server are affected: SIMATIC Drive Controller CPU 1504D TF …
View CSAF Summary Siemens Industrial Edge Devices contain multiple path traversal vulnerabilities that could facilitate an authenticated remote attacker to access sensitive internal information. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens Industrial Edge Devices are…
View CSAF Summary The products listed below contain a vulnerability that could allow an attacker to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SIMATIC IPCs are affected: SIMATIC IPC BX-21A vers:intdot/<31.01.13 (CVE-2026-72895) SIMATIC IPC RW-543A vers…
View CSAF Summary RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code, cause a denial of service, or obtain sensitive information. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Station Access Controller are affected: RUGGEDCOM…
View CSAF Summary The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application. Siemens has released a new version for Siemens Software Center and recommends to update to the latest version. Please refer to our blog post for additional information about…
View CSAF Summary PSS(R)SINCAL uses WibuKey third-party product that contains an out-of-bounds write vulnerability. An attacker could exploit this vulnerability to cause a system crash, resulting in a denial-of-service condition. This affects PSS SINCAL only when configured to use the legacy WibuKey dongle license type. Siemens is actively preparing updates and recommends applicable mitigations for products where patches are currently unavailable. The following versions of Siemens PSS(R)SINCAL…
View CSAF Summary The products listed below contain an out-of-bounds read vulnerability that could allow an attacker to cause abnormal product behavior, instability, or denial of service. Siemens has released a new version for Capital Embedded AR Classic R20-11 and recommends updating to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Capital Embedded…
View CSAF Summary Multiple SIMATIC WinCC versions are affected by a database privilege escalation vulnerability that could allow an authenticated user with access to the database to execute commands on the underlying host system. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends mitigations for products where fixes are not or not yet available. The following versions of Siemens WinCC…
View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.7 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP are affected: SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) vers:intdot/>=3.1.7 SIMATIC S7…
View CSAF Summary The Industrial Edge App Publisher contains a vulnerability chain involving improper certificate validation and the rendering of unescaped data from backend responses. These issues can be combined to allow an attacker on the network to impersonate the management server and execute arbitrary code (RCE) on the local machine through Node.js integration. Siemens has released an update for the Industrial Edge App Publisher and recommends to update to the latest version. The…
View CSAF Summary Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens recommends to contact customer support to receive patch and update information. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-33387, CVE-2026-33388, CVE-2026-33389, CVE-2026-33391, CVE-2026-33920) CVSS Vendor Equipment v3 7.5…
View CSAF Summary RUGGEDCOM CROSSBOW contains multiple vulnerabilities that could allow an attacker to execute arbitrary SQL commands on the underlying database, retrieve sensitive administrative credentials, escalate privileges, and perform unauthorized operations such as modifying system configurations or causing a denial of service. Siemens has released a new version for RUGGEDCOM CROSSBOW and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW…
View CSAF Summary The products listed below contain multiple vulnerabilities that could allow an attacker to cause a denial of service and potentially impact the availability of the affected device. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens APOGEE, TALON and Desigo PXC/PXM Products are affected:…
View CSAF Summary .NET Client Library for SIMATIC S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory. Siemens has released a new version for .NET Client Library for SIMATIC S7 Webserver API and recommends to update to the latest version. The following versions of Siemens SIMATIC S7 Webserver API are affected: .NET Client Library for SIMATIC S7 Webserver API vers:intdot/…
Serial number: AV26-1066 Date: October 20, 2026 As of October 19, 2026, GeoVision is affected by a vulnerability in the following product: GV-ASManager Versions prior to V6.3.0 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. GeoVision Security Advisory - GV-ASM-2026-10-01 (PDF) Cyber Security - GeoVision
Serial number: AV26-1065 Date: October 20, 2026 As of October 20, 2026, Advantech is affected by vulnerabilities in the following product: ADAM-3600 Versions prior to v2.8.5.0 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. Security Advisories - Vulnerabilities Identified in ADAM-3600 (PDF) Advantech Security Advisories
View CSAF Summary Hitachi Energy is aware of multiple vulnerabilities that affect MicroSCADA X SYS600 product versions listed in this document. These vulnerabilities can be exploited to carry out various attacks on the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy MicroSCADA X SYS600 Product are affected: MicroSCADA X SYS600 vers:MicroSCADA_X_SYS600/<=10.7, 10.8 (CVE-2026-9852, CVE-2026-9853,…
View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect RTU500 product versions listed in this document. These vulnerabilities if exploited can have impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy RTU500 Product are affected: RTU500 series CMU Firmware vers:RTU500_series_CMU_Firmware/>=13.5.1|<=13.5.4, vers:RTU500…
View CSAF Summary Two vulnerabilities in the Web-Based Management (WBM) interface of WAGO CC100, PFC100 G2, PFC200 G2, TP600, Edge Controller and WP400 devices allow an authenticated low-privileged user to bypass intended privilege boundaries. The issues affect both the routing configuration functionality and the authorization model for PROFIBUS configuration management. The following versions of WAGO OS Linux are affected: WAGO Firmware (vers:semver/>=1.0.0|<4.10.0) installed on WAGO Hardware…
View CSAF Summary Successful exploitation of these vulnerabilities could crash the Windows kernel. The following versions of HMS Networks PEAK-System PCAN Windows drivers are affected: PEAK-System Device Driver Setup <=5.1.2.1151 (CVE-2026-109576, CVE-2026-101103, CVE-2026-94188, CVE-2026-103672, CVE-2026-110322, CVE-2026-105960) PCAN Windows CAN device drivers <=5.1.2 (CVE-2026-109576, CVE-2026-101103, CVE-2026-94188, CVE-2026-103672, CVE-2026-110322, CVE-2026-105960) CVSS Vendor Equipment v3…
[FSA-202602] Festo AX OS versions 25.0.1.46 and 25.9.2.4, which are based on PLCnext by Phoenix Contact, used by the Festo product CEPE are affected by multiple OpenSSL vulnerabilities. The vulnerabilities are identified as CVE-2025-15467 and CVE-2025-69419. Attacks may be possible when maliciously crafted firmware, key files, PKCS#12 files, CMS/PKCS#7 content, or digitally signed objects are uploaded and processed by the affected system. In the device context, exploitation typically requires a…
[PPSA-2026-005] The 'Pictory' web config tool, prior to 2.17.0, has a Cross-Site Request Forgery (CSRF) vulnerability, which makes it vulnerable to session takeover. The 'revpipyload' package, prior to version 0.11.1, has a vulnerability in the file management functionality of its XML-RPC interface. This allows an attacker to access or delete arbitrary files that the 'revpipyload' process has access to.
[PPSA-2026-004] The 'piControl' kernel module used in the IndustrialPI, prior to version 2.8.0-1, contains multiple vulnerabilities. Successful exploitation of these vulnerabilities can lead to kernel memory corruption and denial of service.
Introduction Imagine you’ve ordered a small paper unicorn from an online marketplace. You clicked “Buy”, received a cheerful notification, and expect a courier to bring the box tomorrow. If the unicorn is delayed by a day, it will be annoying but not catastrophic: an apology, a discount promo code — and the incident is forgotten. Now let’s multiply one late unicorn by several hundred thousand orders. Packages start heading to the wrong cities. The website shows an item is in stock, even though…
Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.1, CVEs: CVE-2026-62927, CVE-2026-63252, CVE-2026-58080, CVE-2026-63248, CVE-2026-60007, CVE-2026-61387, Summary: Successful exploitation of these vulnerabilities could allow an attacker to delete protected data, recover user credentials and impersonate legitimate users, or cause the server to stop responding to all clients. Incorrect Authorization, Missing Release of Memory after Effective Lifetime,…
Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 9.8, CVEs: CVE-2026-107617, CVE-2026-97858, CVE-2026-105664, Summary: Successful exploitation of these vulnerabilities could allow an attacker to gain control over affected IP cameras: Use of Hard-coded Credentials, Improperly Controlled Modification of Dynamically-Determined Object Attributes, Observable Response Discrepancy
I veckans brev bjuder vi bland annat på rekommendationer om cyberfysiska system, insikter om hur cyberkriminella storskaliga nätfiskekampanjer fungerar och en inbjudan till rundabordssamtal med fokus på lärande för att stärka Sveriges cybersäkerhet.
Serial number: AV26-1052 Date: October 15, 2026 As of October 7, 2026, Johnson Controls is affected by a vulnerability in the following product: ADVMS Prior to 3.10 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. Vulnerability impacting American Dynamics VMS - JCI-PSA-2026-17 Johnson Controls Product Security Advisories
Serial number: AV26-1051 Date: October 15, 2026 As of October 13, 2026, Schneider Electric is affected by a vulnerability in the following products: Sage RTU 1410/1430/1450 Versions prior to C3414-500-S02L0 Sage RTU 2400 Versions prior to C3414-500-S02L0 Sage RTU 3030 Magnum Versions prior to C3414-500-S02L0 Sage RTU 4400 Versions prior to C3414-500-S02L0 The Cyber Centre encourages users and administrators to review the provided web link perform the suggested mitigations and apply the…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read arbitrary files on the Torrent Server. The following versions of Thermo Fisher Torrent Suite Software are affected: Torrent Suite Software <=5.18 (CVE-2026-107777) CVSS Vendor Equipment v3 6.5 Thermo Fisher Torrent Suite Software 1 Vulnerability Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Healthcare and Public Health…
Classification: Severe, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 8.8, CVEs: CVE-2026-92817, Summary: Successful exploitation of this vulnerability could allow an authenticated low-level user to escalate their privileges to a higher level.
Classification: Severe, Solution: Workaround, Exploit Maturity: Not Defined, CVSSv3.1: 8.8, CVEs: CVE-2026-107605, CVE-2026-107606, CVE-2026-107607, CVE-2026-92817, Summary: CISA released two Industrial Control Systems (ICS) Advisories. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. *ICSA-26-286-01 Inductive Automation Ignition Software *ICSA-26-286-02 Swann Communications SWIFI-SE2KIC
Critical infrastructure faces mounting threats from nation-state groups and AI-driven attacks. In the latest installment of our Cybersecurity Awareness Month blog series, learn how leading cybersecurity agencies, such as CISA, are advising critical infrastructure organizations on ways to protect themselves and the essential services they provide. Key takeaways Critical infrastructure organizations often struggle with asset visibility gaps that create hidden attack vectors. Many older OT systems…
A cyberattack has forced hundreds of supermarkets across France to throw away refrigerated and frozen food after attackers interfered with the systems that keep it cold. The attack caused significant financial losses and food waste. Some installations reportedly reached temperatures of around 50°C (122°F), with damaged equipment and reports of fires adding to the disruption. The attack, which struck overnight from October 11 to 12, affected stores belonging to Intermarché, Netto, Coopérative U,…
Siemens ha rilasciato aggiornamenti di sicurezza per sanare molteplici vulnerabilità nei propri prodotti, di cui 4 con gravità “critica” e 14 con gravità “alta”.
Siemens heeft kwetsbaarheden verholpen in diverse producten zoals Desigo, Industrial Plus, RUGGEDCOM, SIMATIC en SIPLUS. De kwetsbaarheden stellen een kwaadwillende mogelijk in staat aanvallen uit te voeren die kunnen leiden tot de volgende categorieën schade: - Denial-of-Service (DoS) - Manipulatie van gegevens - Omzeilen van een beveiligingsmaatregel - (Remote) code execution (root/admin rechten) - Toegang tot systeemgegevens - Toegang tot gevoelige gegevens - Verhogen van rechten De…
Une vulnérabilité a été découverte dans Schneider Electric Harmony. Elle permet à un attaquant de provoquer un contournement de la politique de sécurité.
Attackers remotely defrosted refrigerators at multiple French supermarket chains overnight in a cyberattack that reportedly targeted Danfoss refrigeration controllers. [...]
Le CERT-FR a connaissance de nombreuses compromissions des controleurs à distance d'installation de réfrigération Danfoss série AK-SM, AK-SC ainsi que Copeland xweb et Dixell xweb. De manière générale l'exposition d'une interface de gestion sur Internet est contraire aux bonnes pratiques.
Le CERT-FR a connaissance de nombreuses compromissions de Danfoss série AK-SM et AK-SC. L'exposition d'une interface de gestion sur Internet est contraire aux bonnes pratiques. Dans le cas où l’administration à distance est impérative, une première mesure temporaire peut consister à restreindre...