View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect the FACTS Control systems with GWS component listed in this document. An attacker exploiting these vulnerabilities can cause impact on confidentiality, integrity and availability of the product. Following FACTS Control systems with GWS component deployed from year 2020 onwards are likely affected by the above vulnerabilities. Product deployments without GWS component are not affected. • SVC Light (STATCOM) • Fixed Series…
View CSAF Summary Successful exploitation of this vulnerability could allow a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in memory, and thereby allows the attacker to view, tamper with, destroy, or delete control programs. The following versions of Mitsubishi Electric GX Works3 and Motion Control Settings are affected: Mitsubishi Electric GX Works3 vers:all/* (CVE-2026-15688)…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker with access to the same network segment to tamper with communication data in the affected product by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly. The following versions of Mitsubishi Electric CC-Link IE TSN…
Serial number: AV26-927Date: September 16, 2026 As of September 16, 2026, Phoenix Contact is affected by vulnerabilities in the following products: ICE2-8IOL-G65L-V1D Prior to 1.7.4 ICE2-8IOL-K45P-RJ45 Prior to 1.7.4 ICE2-8IOL-K45S-RJ45 Prior to 1.7.4 ICE2-8IOL1-G65L-V1D Prior to 1.7.4 ICE3-8IOL-G65L-V1D Prior to 1.7.4 ICE3-8IOL-G65L-V1D-Y Prior to 1.7.4 ICE3-8IOL-K45P-RJ45 Prior to 1.7.4 ICE3-8IOL-K45S-RJ45 Prior to 1.7.4 ICE3-8IOL1-G65L-V1D Prior to 1.7.4 IOL MA8 EIP DI8 Prior to 1.7.4 IOL…
AI is accelerating vulnerability discovery, leaving unpatchable operational technology (OT) systems at risk. Hoping for the best is not a viable anti-exploitation strategy. Deploying next-generation firewalls directly upstream allows for virtual patching through deep packet inspection. These systems scan incoming traffic to detect and block exploit attempts before they can impact the vulnerable device.The predictability of legitimate network connections to OT systems can be used to protect…
[VDE-2026-028] The affected devices have security vulnerabilities that can be used to bypass authentication. Code can be executed on the devices through command injection and local file inclusion. Path traversal and modified schemata can be used to read sensitive information such as password hashes or private keys from the devices.
Classification: Severe, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.1: 8.6, CVEs: CVE-2026-81573, CVE-2026-81574, CVE-2026-81572, CVE-2026-81576, CVE-2026-81575, Summary: The TRUMPF product versions listed below include a Wibu CodeMeter Runtime version that contains several vulnerabilities, e.g. potentially allowing privilege escalation.
Australia’s move from the Essential Eight to an outcomes-based cybersecurity model will push organizations from conducting periodic point-in-time, checklist compliance assessments to having continuous evidence of a solid security posture.Key takeawaysThe Australian Signals Directorate (ASD) is moving from the Essential Eight cybersecurity framework to a new outcomes-focused Essentials series covering enterprise IT, cloud, operational technology (OT), and potentially agentic AI.The Essential…
View CSAF Summary Siemens Reyrolle 7SR5 Before V2.70 is affected by multiple vulnerabilities. Siemens has released a new version for Reyrolle 7SR5 and recommends to update to the latest version. The following versions of Siemens Reyrolle 7SR5 are affected: Reyrolle 7SR5 vers:intdot/<2.70 (CVE-2024-42384, CVE-2024-42385, CVE-2024-42386, CVE-2024-42391, CVE-2024-42392, CVE-2026-62645, CVE-2026-62646, CVE-2026-62647, CVE-2026-62648, CVE-2026-62649, CVE-2026-62650, CVE-2026-62652, CVE-2026-62653,…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to deliver an unauthorized update, execute code, or extract credentials to allow the attacker to impersonate a privileged client. The following versions of Wärtsilä FOS-Onboard are affected: FOS-Onboard 5.07.0923.01 (CVE-2026-78225, CVE-2026-81855) CVSS Vendor Equipment Vulnerabilities v3 9.1 Wärtsilä Wärtsilä FOS-Onboard Use of Hard-coded Cryptographic Key Background Critical Infrastructure Sectors:…
View CSAF Summary A reflected cross site scripting vulnerability in the authentication redirect flow (/auth/) of Teamcenter allows an unauthenticated remote attacker to inject JavaScript into an authenticated user's session by crafting a malicious URL. Successful exploitation may enable the attacker to read data or perform actions within the victim's Teamcenter session. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following…
View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the Secure Lock functionality, potentially resulting in a loss of confidentiality. The…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access privileged management functions or send arbitrary SMS messages through the connected GSM modem. The following versions of mySCADA myPRO Manager are affected: mySCADA myPRO Manager <=2.1 (CVE-2026-73807, CVE-2026-82567) CVSS Vendor Equipment Vulnerabilities v3 9.8 mySCADA Technologies mySCADA myPRO Manager Missing Authorization, Missing Authentication for Critical Function Background Critical…
Serial number: AV26-914Date: September 11, 2026 As of September 10, 2026, National Instruments is affected by vulnerabilities in the following products: SystemLink Prior to or equal to 2026 Q3 Patch 1 SystemLink Server Prior to or equal to 2026 Q3 Patch 1 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available./p> Improper Access Controls in NI SystemLink Storage of Sensitive Information in Cleartext in NI…
Serial number: AV26-913Date: Septembre 11, 2026 As of September 10, 2026, GeoVision is affected by vulnerabilities in the following product:: GV-LPC2011/LPC2211 Firmware version 1.13 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. GeoVision Security Advisory - GV-LPC-2026-09-01 Cyber Security - GeoVision
Serial number: AV26-912Date: September 11, 2026 As of September 9, 2026, Schneider Electric is affected by vulnerabilities in the following products: EcoStruxure™ IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) Versions 9.1.2 and prior PowerLogic T300 Versions 2.9.8-5620 and prior The Cyber Centre encourages users and administrators to review the provided web links, perform the suggested mitigations and apply the necessary updates. Multiple Vulnerabilities on…
Serial number: AV26-907Date: September 10, 2026 As of September 10, 2026, Advantech is affected by vulnerabilities in the following product: Advantech WISE-6610 industrial gateway Multiple versions and models The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. Vulnerabilities Identified in WISE-6610 Security Advisories - Advantech
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose information, brute-force hashes, or run arbitrary code in a browser session. The following versions of AVEVA Pipeline Integrity Monitor are affected: AVEVA Pipeline Integrity Monitor <=2025_SP1_P1_build_7.1.9580.8513 (CVE-2026-81821, CVE-2026-81822, CVE-2026-81823, CVE-2026-81824) CVSS Vendor Equipment Vulnerabilities v3 8.4 AVEVA AVEVA Pipeline Integrity Monitor Use of Hard-coded…
Serial Number: AV26-892Date: September 8, 2026 As of September 4, 2026, Inductive Automation is affected by a vulnerability in the following product: Ignition Prior to or equal to 8.1.53 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. CSAF/csaf_files/OT/white/2026/icsa-26-246-06.json at develop · cisagov/CSAF · GitHub Inductive Automation Ignition | CISA
Serial Number: AV26-890Date: September 8, 2026 As of September 8, 2026, Siemens is affected by vulnerabilities in the following products: Reyrolle 7SR5 Versions prior to V2.70 Teamcenter Multiple versions and models Siveillance Control Multiple versions and models SIMATIC AX Runtime Multiple versions and models Desigo CC Product Family Multiple versions and models Industrial Edge Management Multiple versions and models SIMOVE Fleetmanager and SIPLANT Multiple versions and models The Cyber…
Siemens heeft kwetsbaarheden verholpen in diverse producten als Desigo, Reyrolle, SIMATIC, SCALANCE, SINAMICS en Siveillance. De kwetsbaarheden stellen een kwaadwillende in staat aanvallen uit te voeren die kunnen leiden tot de volgende categorieën schade: * Denial-of-Service (DoS) * Manipulatie van gegevens * Omzeilen van een beveiligingsmaatregel * (Remote) code execution (root/admin rechten) * (Remote) code execution (gebruikersrechten) * Toegang tot gevoelige gegevens * Verhogen van rechten…
Schneider Electric ha rilasciato aggiornamenti di sicurezza per sanare molteplici vulnerabilità nei propri prodotti, di cui 1 con gravità “critica” e 3 con gravità “alta”.
De multiples vulnérabilités ont été découvertes dans Schneider Electric EcoStruxure. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance et une falsification de requêtes côté serveur (SSRF).
Amir Yaryab is the leader of the IRGC's cyber unit and oversees hacker groups such as the CyberAv3ngers, the State Department said in posting a reward for information about him.
View CSAF Summary Successful exploitation of this vulnerability could result in memory corruption, a device crash, or a potential remote attack vector without the originating device receiving a CIP error indicating that the request could not be processed. The following versions of Pyramid Solutions NetStaX EtherNet/IP Stack are affected: EtherNet/IP Adapter DLL Kit (EIPA) EtherNet/IP Adapter DLL Kit with CIP Security (EIPA-SECURE) EtherNet/IP Adapter Development Kit (EADK) EtherNet/IP Adapter…
View CSAF Summary Successful exploitation of these vulnerabilities could result in a loss of webserver availability or allow an attacker to inject malicious scripts that will be executed when other users access the affected page. The following versions of Rockwell Automation ArmorStart LT are affected: ArmorStart LT <=v2.001 (CVE-2026-19471, CVE-2026-19472) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation ArmorStart LT Improper Neutralization of Input During…
View CSAF Summary Successful exploitation of this vulnerability could give an attacker the ability to run any commands or code of the attacker's choice on a target machine at the logged-in user's permission level. The following versions of Rockwell Automation ControlFLASH are affected: ControlFLASH <=V15.07 (CVE-2026-12663) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation ControlFLASH Missing Authentication for Critical Function Background Critical…
View CSAF Summary Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra…
View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to perform a man-in-the-middle (MitM) attack, cause a factory reset, wipe credentials, or retrieve sensitive information. The following versions of Tycon Systems TPDIN-Monitor-WEB3 are affected: TPDIN-Monitor-WEB3 <=2.2.9 (CVE-2026-77847, CVE-2026-82712, CVE-2026-82684) CVSS Vendor Equipment Vulnerabilities v3 8.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB3 Use of Hard-coded Credentials, Cross-Site…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to take control of a high-privilege terminal during installation and run arbitrary commands. The following versions of OPCFoundation OPC UA LocalDiscoveryServer (LDS) are affected: UA-LDS-Installers <1.04.420 (CVE-2026-77477) CVSS Vendor Equipment Vulnerabilities v3 4.6 OPCFoundation OPCFoundation OPC UA LocalDiscoveryServer (LDS) Execution with Unnecessary Privileges Background Critical Infrastructure…
View CSAF Summary Successful exploitation of this vulnerability could allow any authenticated user to create projects. The following versions of Inductive Automation Ignition are affected: Ignition <=8.1.53 (CVE-2026-77393) CVSS Vendor Equipment Vulnerabilities v3 8.8 Inductive Automation Inductive Automation Ignition Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company…
View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker accessing sensitive credentials, disrupting connected infrastructure, or manipulating physical equipment, which could present a physical safety risk. The following versions of Tycon Systems TPDIN-Monitor-WEB2 (Update A) are affected: TPDIN-Monitor-WEB2 <2.4.5 (CVE-2026-61884, CVE-2026-55985) CVSS Vendor Equipment Vulnerabilities v3 9.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB2 Missing…
View CSAF Summary Successful exploitation of this vulnerability could crash the module. The device requires a restart to recover. The following versions of Rockwell Automation 1756-ENBT Module are affected: 1756-ENBT module vers:all/* (CVE-2025-10478) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1756-ENBT Module Improper Check for Unusual or Exceptional Conditions Background Critical Infrastructure Sectors: Critical Manufacturing, Food and Agriculture,…
Classification: Severe, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv3.0: 8.6, CVEs: CVE-2026-9621, CVE-2026-9622, CVE-2026-9624, CVE-2026-9625, CVE-2026-9633, CVE-2026-9634, CVE-2026-9637, CVE-2026-16675, Summary: Rockwell Automation FactoryTalk Activation Manager Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition on the affected product. The following versions of Rockwell Automation RSLinx Classic are affected: RSLinx…
Serial Number: AV26-871Date: September 2, 2026 As of September 1, 2026, Schneider Electric is affected by vulnerabilities in the following products: NetBotz 5 - 750/755 Versions prior to or equal to 5.5.2 PowerChute Serial Shutdown Versions prior to or equal to 1.5 The Cyber Centre encourages users and administrators to review the provided web links, perform the suggested mitigations and apply the necessary updates. Multiple Vulnerabilities on NetBotz 5 - 750/755 Products Improper Restriction…
Developed by CISA, the Federal Bureau of Investigation, and international partners, this guidance describes how organizations can plan and execute clear, timely, accurate, and audience-appropriate communications during IT and operational technology (OT) outages. Whether caused by cyber threat actors, human error, equipment failure, or natural hazards, service outages can create disruption and societal panic even without speculation from end users and the public as added factors. Outages at one…
Serial number: AV26-869Date: September 1, 2026 As of September 1, 2026, Rockwell Automation is affected by vulnerabilities in the following products: 1756-ENBT Module All versions ArmorStart LT Prior to or equal to v2.001 CompactLogix 5380 / ControlLogix 5580 Prior to or equal to V33 V34.011 to V34.014 V35.011 to V35.013 V36.011 to V36.012 RSLinx Classic Prior to or equal to V4.50 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary…
View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to escalate and execute processes with administrator privileges. The following versions of Rockwell Automation Redundancy Module Configuration Tool are affected: Redundancy Module Configuration Tool 10.00.00 (CVE-2026-9633) Redundancy Module Configuration Tool >=9.00.00|<=10.00.00 (CVE-2026-9634) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation Redundancy Module…
View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed; an out-of-bounds write condition may allow remote code execution. The following versions of Rockwell Automation Historian ME are affected: Series B 5.202 (CVE-2025-12768, CVE-2026-12661) Series C 7.101 (CVE-2025-12768, CVE-2026-12661) CVSS Vendor Equipment Vulnerabilities v3 8 Rockwell Automation Rockwell Automation Historian ME Out-of-bounds Write, Stack-based Buffer Overflow Background…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition on the affected product. The following versions of Rockwell Automation RSLinx Classic are affected: RSLinx Classic <=4.50 (CVE-2026-9621, CVE-2026-9622, CVE-2026-9624, CVE-2026-9625) CVSS Vendor Equipment Vulnerabilities v3 8.6 Rockwell Automation Rockwell Automation RSLinx Classic Integer Overflow or Wraparound, Integer Underflow (Wrap or Wraparound), Buffer Copy…
[VDE-2026-093] A vulnerability has been found in the firmware update process of SAUTER Building Controllers. The identified vulnerability could allow unauthorized code execution on affected controllers.
Serial Number: AV26-864Date: August 31, 2026 As of August 27, 2026, Siemens is affected by a vulnerability in the following products: Element maps-ng V47 Prior to V47.12.3 Element maps-ng V48 Prior to V48.11.3 Element maps-ng V49 Prior to V49.16.1 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. SSA-682041 CERT Services | Siemens
Serial Number: AV26-856Date: August 28, 2026 As of August 25, 2026, National Instruments is affected by vulnerabilities in the following product: LabVIEW Prior to 23.0.0 Prior to 23.3.10 Prior to 24.3.7 Prior to 25.3.5 Prior to 26.3.1 The Cyber Centre encourages users and administrators to review the provided web links and apply any necessary updates as they become available. Memory Corruption Vulnerabilities in NI LabVIEW - NI Integer Conversion Vulnerability Resulting in an Out of Bounds Read…
[VDE-2026-061] An information disclosure vulnerability in the web GUI of Murrelektronik Xelity switches causes MAC addresses from the device's MAC address table to be written into a server-side log that is exposed via the device's web interface to unauthenticated users. The leak is triggered when an authenticated administrator invokes the 'Copy learned MAC Addresses' function, which causes a syslog error that inserts the affected MAC addresses into the log output. Once the error has been…
[VDE-2026-083] Weidmueller security routers IE-SR-2TX-WL and IE-SR-2TX-WL-4G are affected by an unauthenticated remote code execution vulnerability. IE-SR-2TX-WL-4G routers are also affected by a SMS password authorization bypass vulnerability. Weidmueller has released new firmware versions of the affected products to fix the vulnerabilities.
[VDE-2026-078] Frauscher Sensortechnik FDS102 for FAdC/FAdCi R2 is vulnerable to Unrestricted Upload of File with Dangerous Type, Path Traversal: '../filedir', Insertion of Sensitive Information into Log File, Incorrect Authorization, Insufficient Session Expiration, Cross-Site Request Forgery (CSRF), Missing Authentication for Critical Function, and Missing Authorization.
You can’t patch everything. So what do you fix first? Findings in Q2 2026 have changed traditional answers.The latest Quarterly Threat Landscape Report from Rapid7 Labs shows vulnerability disclosures still surging while attackers use automation and AI-assisted tooling to compress the time between disclosure and exploitation. The gap that patch cycles were built to fill is closing. Speed and volume are overwhelming security teams that have relied on traditional patch cycles and reactive…
[vde-2025-056] This advisory addresses multiple security vulnerabilities in PLCnext firmware versions prior to 2026.0.3. The vulnerabilities may allow unauthenticated attackers to cause denial of service, trigger unexpected system behavior, or execute unauthorized SQL queries. Successful exploitation could impact the availability, integrity, and confidentiality of affected PLCnext Control devices. All issues are resolved in PLCnext firmware version 2026.0.3.
[VDE-2025-007] The Year 2038 Problem affects systems using a 32-bit integer to represent time as the number of seconds since January 1, 1970. On January 19, 2038, at 03:14:07 UTC, the time value will exceed the maximum for a 32-bit integer, causing an overflow and resetting it to a negative number.
[PPSA-2026-003] The Linux kernel used in the IndustrialPI, 'linux-image-revpi-v8', prior to version 6.12.91-revpi0-rpi-v8 contains multiple vulnerabilities. Successful exploitation of these vulnerabilities can give an attacker full control over the device.
For the latest discoveries in cyber research for the week of 27th July, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES Minnesota IT Services has confirmed coordinated cyberattacks affecting more than 30 community water utilities across the state. The incidents briefly disrupted a treatment plant in Braham and affected industrial control systems. Officials reported that drinking water safety was not affected. While the attack was not officially attributed, federal…
[VDE-2026-065] A vulnerability in the iDTM FDI allows an attacker with elevated privileges and access to the host system to enable the debug interface by placing a crafted file in the application directory.
Canada’s new Critical Cyber Systems Protection Act (Bill C-8) introduces a strict 72-hour cyber incident reporting mandate. Find out how Tenable is helping critical national infrastructure operators bridge the IT/OT divide to ensure full compliance.Key takeaways:Bill C-8 introduces stringent new cyber incident reporting requirements and heavy financial penalties for critical infrastructure operators. Eliminating network blind spots with a hybrid IT/OT discovery approach, including Safe Active…
[VDE-2026-008] Multiple vulnerabilities have been identified in the firmware of CHARX SEC-3xxx EV charging controllers, including the CHARX SEC-3000, SEC-3050, SEC-3100, and SEC-3150 models. The flaws could allow attackers to compromise the devices remotely, resulting in a complete loss of confidentiality, integrity, and availability.